Harman Stove Company P43 Automatic Ignition ESP Control, Status light error messages

Page 14

P43 AUTOMATIC IGNITION ESP CONTROL

Power Light Indicates power to the control.

Status Light

Will be lit in either stove or room temp mode when pointer is not within off position band except after normal shut down. Blinks to indicate errors listed below.

Indicates power to distribution blower.

Feed adjuster Sets the maximum feed rate

Test

Runs all motors at full speed for one minute to check operation. After two minutes the stove will go to minimum burn and the blowers will alternate from high to low every minute to remind you that you are still in "Test Mode".

Igniter switch Set to appropriate Start-Up mode.

Indicates power to combustion blower

Indicates power to the feed motor.

Indicates power to the igniter

Temp dial

Allows you to adjust the room temperature in Room Temp Mode using the outer scale marked in degrees Fahrenheit. It also allows you to adjust the stove temperature while in Stove Temp Mode using the inner scale marked from 1 to 7.

Dealer Diagnostic Port For dealer maintenance only. Requires special DDM monitor supplied to Harman Dealers exclusively.

Distribution Blower s p e e d a d j u s t m e n t range.

L = low

H = high

V a r i a b l e s p e e d anywhere between L and H; although as the stove temp. goes up , so does the low end of the scale.

Mode Selector

Allows you to choose between Room Temp Mode, Stove Temp Mode, or OFF. Also allows you to vary the distribution blower speed by turning the knob to the high or low side of each mode.

Status light error messages:

1 Blink: Indicates control board self diagnostic fail- ure. This requires a manual reset*.

3 Blinks: Indicates ESP (Exhaust Sensing Probe) failure. This requires a manual reset*.

4 Blinks: Can occur only in Room Temp Mode and indicates Room Sensing Probe failed or not installed. If a Room Sensing Probe is then installed, the status light will automatically reset.

5 Blinks (In Igniter Auto. Mode Only): Indicates that the unit has failed to light within the 36 minute start cycle. To reset - Turn Mode Selector to "OFF", then turn to either mode again.

6 Blinks : Indicates that the control has calculated poor or incomplete combustion occurring for more than 50 minutes.

A six blink status may be set if the stove is allowed to run out of pellets. To reset, turn mode selector to "OFF" then back on to the desired mode. If the unit was not out of pellets, see Troubleshooting section, Page 26, for more details.

*Manual reset- disconnect power cord for a few seconds and reconnect. If error still occurs call your Dealer.

14P43 Pellet Stove

Image 14
Contents Installation & Operating Manual Safety NoticeWHI Table of Contents IntroductionImportant Notes Removing rear cover panels Assembly and InstallationUnpacking FirebrickInstallation InstallingAddition, the following must be observed With outside air installed, 6 feetVenting Venting Vent PipeDirect Vent Wall Passthrough Kit Outside Air#1 Preferred method #2 Preferred methodFireplace chimney #4 Installing into an existing chimney#5 Installing into an existing #6 Installing into an existing fireplace chimney #7 Installing into an existing chimneyMinimum flue vent configuration #8 Installing through the ceilingStatus light error messages P43 Automatic Ignition ESP ControlRoom Temperature Mode P43 Automatic IGNITION/OPERATIONShut Down Procedure Stove Temperature ModeFeed Adjuster Knob P43 Automatic Start UP Flame Guide SeeHint #7Manual Stove Temperature Mode P43 Manual IGNITION/OperationIgniter Switch toMANUAL down position P43 Manual Start UPP43 Low Draft Voltage Adjustment Low Draft Voltage AdjustmentRear Shields Room Sensor and Rear Shield InstallationRoom Sensor Installation Cleaning MaintenanceCleaning the Door Glass Removing AshesSoot and Fly Ash P43 Maintenance Burn Pot Burn Pot Cleaning and MaintenanceP43 Maintenance Cleaning the Feeder Body Pellet Fines will build up in this areaP43 Trouble-Shooting Cleaning Burn PotP43 Feeder 28.5 P43 Specifications12.375 Options P43 Wiring Diagram P43 Parts List Description Part NumberHarman Gold Warranty

P43 specifications

The Harman Stove Company P43 is a sophisticated pellet stove renowned for its efficiency, versatility, and modern design. Tailored for homeowners who seek both functionality and aesthetic appeal, the P43 offers a compelling option for heating spaces while contributing to an environmentally friendly lifestyle.

At the heart of the P43 is its impressive heating capacity. It can warm areas up to 1,200 square feet, making it suitable for a variety of home sizes. Its heat output ranges from a low of 8,200 BTUs to a maximum of 43,000 BTUs, allowing users to customize heating levels according to their needs. This adaptability is further enhanced by the unit's easy-to-use control settings that enable precise adjustments for different heating requirements and comfort levels.

One standout feature of the P43 is its efficient heat exchanger system. This technology promotes optimal combustion, ensuring that the maximum amount of heat is produced while minimizing waste. As a result, not only does this contribute to cost-effective heating, but it also enhances the stove's environmental performance by reducing emissions. The P43 is certified by the EPA, confirming its compliance with stringent environmental standards.

The P43 also integrates advanced automation technologies, such as Touch Control Technology, which simplifies the operation of the stove. Users can easily manage settings through a digital interface, allowing for setting timers, adjusting burn rates, and monitoring fuel levels. This level of automation makes it particularly appealing for tech-savvy homeowners who appreciate convenience in their heating solutions.

Another defining characteristic of the P43 is its design. With a sleek, modern look, the pellet stove is available in different finishes, allowing it to seamlessly blend into various home decors. The window remains large and unobstructed, providing a clear view of the fire and enhancing the ambiance of any room.

Additionally, Harman’s renowned build quality ensures that the P43 is not only functional but also durable. Constructed from high-quality materials, the stove is designed to offer long-lasting performance. The unit's efficient fuel feeding system minimizes the need for constant refueling, further enhancing its usability.

Overall, the Harman Stove Company P43 represents a perfect fusion of technology, efficiency, and design. Its strong performance, user-friendly interface, and aesthetic appeal make it a leading choice for those who prioritize comfort and sustainability in their home heating solutions.