Harman Stove Company P43 owner manual Whi

Page 2

 P43 Pellet Stove

LISTED PELLET FUEL BURNING ROOM HEATER APPAREIL DE CHAUFFAGE CATALOGUÉ DE

MODÈLE POUR BRÛLER DES BOULETTES COMBUSTIBLES.

DO NOT REMOVE THIS LABEL.

MODEL / MODÈLE: "PP 38+" / "P43"

NE PAS ENLEVER CETTE ÉTIQUETTE.

W/N 02531

WHI -

 

INSTALL WITH MINIMUM CLEARANCES TO WALLS AS

TESTED TO : UL 1482 ASTM E1509

 

 

 

 

SHOWN / INSTALLER AVEC LES DISTANCES MINIMUM

OREGON 814-23-900

 

 

BAR CODE LABEL

 

DE SECURITÉ COMME INDIqUÉ.

ULC-S627

 

 

 

SIDEWALL-BACkWALL

SIDEWALL-BACkWALL

WH-PN 025

 

 

 

 

 

INSTALLATION WITH

INSTALLATION WITHOUT

TEST DATE: JUNE 1997

 

 

 

SIDE SHIELDS

SIDE SHIELDS

MINIMUM CLEARANCES

WITHOUT

WITH

 

2"/51mm

2"/ 51mm

TO COMBUSTIBLES:

SIDE SHIELDS

SIDE SHIELDS

 

 

 

SIDEWALL TO STOVE

16"

10"

 

 

 

BACKWALL TO STOVE

2"

2"

 

 

16"

CEILING TO STOVE TOP

18"

18"

 

10"

406mm

STOVE CORNER TO DIAGONAL WALL

9"

9"

 

254mm

 

PREVENT HOUSE FIRES, OPERATE WITH VIEWING & ASH DOOR CLOSED.

DISTANCES AUX MURS

DISTANCES AUX MURS

UNIT MUST BE PLACED ON A NON-COMBUSTIBLE FLOOR PROTECTOR EXTENDING

LATÉRAL ET ARRIÈRE AVEC

LATÉRAL ET ARRIÈRE SANS

6" TO THE FRONT, 6" TO SIDES AND 1" TO REAR. MEASURE FRONT FROM GLASS.

PROTECTIONS MURALES

PROTECTIONS MURALES

EXHAUST TYPE: LISTED TYPE LOR PLVENT INSTALLED TO VENT MANUFACTURER'S

FLOOR PROTECTOR

CORNER INSTALLATION 9" WITH

INSTRUCTIONS AND LOCAL BUILDING CODES.

 

 

MINIMUM SIzE

OR WITHOUT SIDE SHIELDS

ELECTRICAL RATING: 6 AMPS, 120 VOLTS, 60 HERTZ

 

 

1"/25mm

 

 

 

 

 

FUEL: PELLETIZED OR BIOMASS

 

 

 

 

9" / 229mm

INSTALL AND USE ONLY IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION

 

 

 

AND OPERATING INSTRUCTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS

6" /

6" /

 

ABOUT RESTRICTIONS & INSTALLATION INSPECTION IN YOUR AREA.

152mm

152mm

 

EPA EXEMPT PER 40 CFR 60.534, METHOD 28A.

 

 

 

9" /

APPROVED FOR USE IN MOBILE HOMES.

 

 

 

6" /

229mm

INPUT RATING: .75 TO 5.5 LBS PER HOUR.

 

 

152mm

 

 

 

 

TAILLE MINIMALE

INSTALLATION EN ANGLE 229mm

DO NOT CONNECT THIS UNIT TO A CHIMNEY SERVING ANOTHER APPLIANCE.

DE LA PROTECTION DE SOL.

AVEC OU SANS PROTECTIONS

NE PAS CONNECTER CET APPAREIL À UNE CHEMINÉE SERVANT UN AUTRE

 

 

MURALES

APPAREIL.

 

 

 

 

 

Manufactured By / Fabrique Par:

352 MOUNTAIN HOUSE ROAD

HALIFAX, PA 17032

ESPACES LIBRES MINIMUM

SANS LES

AVEC LES

PROTECTEURS

PROTECTEURS

DES MATÉRIAUX COMBUSTIBLES:

DE CÔTÉ

DE CÔTÉ

DU MÛR DE CÔTÉ AU POÊLE

406 mm

254 mm

DU MÛR ARRIÈRE AU POÊLE

51 mm

51 mm

DU PLAFOND AU DESSUS DU POÊLE

457 mm

457 mm

DU COIN DU POÊLE AU MÛR DIAGONAL

229 mm

229 mm

PRÉVENIR LES FEUX DE MAISONS. OPÉRER SEULEMENT AVEC LA PORTE D'OUVERTURE ET LA PORTE DES CENTRES FERMÉES. L'APPAREIL DOIT ÊTRE PLACÉ SUR UN PLANCHER PROTECTEUR INCOMBUSTIBLE, CELUI-CI S'ÉTENDANT DE 152 mm EN AVANT, DE 152 mm DES CÔTÉS ET D 25 mm DE L'ARRIÈRE.

SORTE D'ÉCHAPPEMENT: VENTILATEUR DE TYPE L OU PL INSTALLÉ SELON LES INSTRUCTIONS DU FABRICANT ET SELON LES CODES LOCAUX DE LA CONSTRUCTION.

PUISSANCE ÉLECTRIqUE: 6 AMPS, 120 VOLTES, 60 HERTZ

COMBUSTIBLE: DE BOULETTES COMBUSTIBLES OU BIOMASSES.

INSTALLER ET UTILISER SELON LES INSTRUCTIONS D'INSTALLATION ET D'OPÉRATION DE FABRICANT. CONTACTER LE BUREAU DE LACONSTRUCTION OU LE BUREAU DES POMPIERS AU SUJET DES RESTRICTIONS ET DES INSPECTIONS D'INSTALLATION DANS VOTRE VOISINAGE.

EXEMPTION EPA PAR 40 CFR 60.534, DE MÉTHODE 28a APPROUVÉ POUR L'USAGE DANS LES MAISONS MOBILES PUISSANCE ESTIMÉE: .75 À 5.5 LBS PAR HEURE.

MADE IN USA

P.N. 3-90-04300

Image 2
Contents Installation & Operating Manual Safety NoticeWHI Table of Contents IntroductionImportant Notes Removing rear cover panels Assembly and InstallationUnpacking FirebrickInstallation InstallingAddition, the following must be observed With outside air installed, 6 feetVenting Venting Vent PipeDirect Vent Wall Passthrough Kit Outside Air#1 Preferred method #2 Preferred methodFireplace chimney #4 Installing into an existing chimney#5 Installing into an existing #6 Installing into an existing fireplace chimney #7 Installing into an existing chimneyMinimum flue vent configuration #8 Installing through the ceilingStatus light error messages P43 Automatic Ignition ESP ControlRoom Temperature Mode P43 Automatic IGNITION/OPERATIONShut Down Procedure Stove Temperature ModeFeed Adjuster Knob P43 Automatic Start UP Flame Guide SeeHint #7Manual Stove Temperature Mode P43 Manual IGNITION/OperationIgniter Switch toMANUAL down position P43 Manual Start UPP43 Low Draft Voltage Adjustment Low Draft Voltage AdjustmentRear Shields Room Sensor and Rear Shield InstallationRoom Sensor Installation Cleaning MaintenanceCleaning the Door Glass Removing AshesSoot and Fly Ash P43 Maintenance Burn Pot Burn Pot Cleaning and MaintenanceP43 Maintenance Cleaning the Feeder Body Pellet Fines will build up in this areaP43 Trouble-Shooting Cleaning Burn PotP43 Feeder 28.5 P43 Specifications12.375 Options P43 Wiring Diagram P43 Parts List Description Part NumberHarman Gold Warranty

P43 specifications

The Harman Stove Company P43 is a sophisticated pellet stove renowned for its efficiency, versatility, and modern design. Tailored for homeowners who seek both functionality and aesthetic appeal, the P43 offers a compelling option for heating spaces while contributing to an environmentally friendly lifestyle.

At the heart of the P43 is its impressive heating capacity. It can warm areas up to 1,200 square feet, making it suitable for a variety of home sizes. Its heat output ranges from a low of 8,200 BTUs to a maximum of 43,000 BTUs, allowing users to customize heating levels according to their needs. This adaptability is further enhanced by the unit's easy-to-use control settings that enable precise adjustments for different heating requirements and comfort levels.

One standout feature of the P43 is its efficient heat exchanger system. This technology promotes optimal combustion, ensuring that the maximum amount of heat is produced while minimizing waste. As a result, not only does this contribute to cost-effective heating, but it also enhances the stove's environmental performance by reducing emissions. The P43 is certified by the EPA, confirming its compliance with stringent environmental standards.

The P43 also integrates advanced automation technologies, such as Touch Control Technology, which simplifies the operation of the stove. Users can easily manage settings through a digital interface, allowing for setting timers, adjusting burn rates, and monitoring fuel levels. This level of automation makes it particularly appealing for tech-savvy homeowners who appreciate convenience in their heating solutions.

Another defining characteristic of the P43 is its design. With a sleek, modern look, the pellet stove is available in different finishes, allowing it to seamlessly blend into various home decors. The window remains large and unobstructed, providing a clear view of the fire and enhancing the ambiance of any room.

Additionally, Harman’s renowned build quality ensures that the P43 is not only functional but also durable. Constructed from high-quality materials, the stove is designed to offer long-lasting performance. The unit's efficient fuel feeding system minimizes the need for constant refueling, further enhancing its usability.

Overall, the Harman Stove Company P43 represents a perfect fusion of technology, efficiency, and design. Its strong performance, user-friendly interface, and aesthetic appeal make it a leading choice for those who prioritize comfort and sustainability in their home heating solutions.