Harman Stove Company Conquest Gas Stove manual Changing to Natural Gas, Natural Gas Conversion Kit

Page 14

Only For Qualified Installers

INSTALLATION

14

Changing to Natural Gas

1

Remove four bolts and remove burner module from stove.

2

Use a 1/2” deep well socket to remove the LP #53 orifice and replace with the #37 Natural gas orifice from the kit.

3

Remove pilot tower with a 7/16” wrench. Replace

LP orifice with Natural Gas orifice. See instructions in kit.

Natural Gas Conversion Kit

NG Pilot Orifice

NG Orifice #37

NG Conversion label

NG Valve

Conversion

Module

NG Conversion

Instructions

Natural Gas Kit

Part No. 1-00-09112

This kit is only for use in the Conquest direct vent gas stove.

4

Remove the three screws that hold the LP knob module in place. Remove the module and replace with the Natural gas module from the kit. See kit instructions.

Image 14 Contents
Safety Notice Harman Conquest Gas StoveFor Your Safety What to do if YOU Smell GAS Table of Contents Introduction4 OPERATION5 OperationOPERATION6 Pilot FlamesSPECIFICATIONS7 Ratings NaturalAlcove Clearances SpecificationsCorner Clearances Installation 8 x Description Use Only Approved VentingPart Numbers for SimpsonDura-Vent Pipe and Fittings Conquest Rear VentRequirements for Terminating the Venting Feet INSTALLATION13Damper Settings Natural Gas Kit Changing to Natural GasNatural Gas Conversion Kit INSTALLATION15 Ember Placement INSTALLATION16Log Placement Deflector plateInstalling Tiles Tile KitRemote Control Kit Installation OptionsConnecting the Optional Thermostat Optional Blower Removing the Glass Front MaintenanceCleaning the Glass Replacing the GasketCleaning the Burners MAINTENANCE21Cleaning the Log Set and Firebox Inspecting the VentingDiagram 120 Volt MAINTENANCE22Optional Blower Wiring Model Conquest WHI #Parts Glass gasket 7’/unitMAINTENANCE25 Burner PartsReplace Piezo Ignitor Turn on gas valve Replenish supply YesBad ReplaceCheck inlet pressure Trouble ShootingGood Replace ValveBad Is Pilot lit11 WC Optional Blower LabelOrifice Size Input Btu/h 27,500 Converted ByDateYear Transferable Limited Warranty Residential Harman Gold WarrantyHarman Gold Warranty Year Limited Warranty Commercial