Harman Stove Company Conquest Gas Stove manual OPERATION5, Operation

Page 5

OPERATION5

Piezo Ignitor

Button

High-Low

Gas Control

PILOT

Operation

HOW TO LIGHT THE FIRE

1.STOP! Read the safety information on the front cover of this manual.

2.If using the optional thermostat, set thermostat to the lowest setting.

3.Turn off electric power to the optional blower.

4.Turn the ON-OFF switch to the OFF position.

5.Push in the gas control knob slightly and turn it clockwise to "OFF." NOTE: THE KNOB CANNOT BE TURNED FROM "PILOT" TO "OFF" UNLESS IT IS PUSHED IN SLIGHTLY. DO NOT FORCE IT.

6.Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow "B" in the safety information on the front cover. If you don't smell gas, go to the next step.

7.Set the High-Low Regulator to High by turning it fully counterclockwise.

8.Press in the gas control knob slightly and turn counterclockwise to "PILOT."

9.Find the pilot by looking down between the logs as shown at lower left.

10.Push the control knob fully down and hold. Immediately push the red piezo ignitor button to light the pilot. It is normal to have to push the red button several times before the pilot ignites. Continue to hold the control knob in for about

one (1) minute after the pilot is lit. Release the knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5

through 10.

•If the knob does not pop up when re- leased, stop and immediately call your service

technician or gas supplier.

•If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service technician or gas supplier.

11.Turn the gas control knob counterclockwise to "ON."

12.Place the ON-OFF switch in the ON position or turn up the thermostat setting if the optional thermostat is used.

13.Turn on the electric power to the optional blower if installed.

14.Set the optional thermostat to the desired room temperature.

Image 5 Contents
Harman Conquest Gas Stove Safety NoticeFor Your Safety What to do if YOU Smell GAS Table of Contents Introduction4 Operation OPERATION5Pilot Flames OPERATION6Ratings Natural SPECIFICATIONS7Alcove Clearances SpecificationsCorner Clearances Installation 8 x Description Use Only Approved VentingPart Numbers for SimpsonDura-Vent Pipe and Fittings Rear Vent ConquestRequirements for Terminating the Venting Feet INSTALLATION13Damper Settings Natural Gas Kit Changing to Natural GasNatural Gas Conversion Kit INSTALLATION15 Log Placement INSTALLATION16Ember Placement Deflector plateTile Kit Installing TilesRemote Control Kit Installation OptionsConnecting the Optional Thermostat Optional Blower Cleaning the Glass MaintenanceRemoving the Glass Front Replacing the GasketCleaning the Log Set and Firebox MAINTENANCE21Cleaning the Burners Inspecting the VentingDiagram 120 Volt MAINTENANCE22Optional Blower Wiring WHI # Model ConquestGlass gasket 7’/unit PartsBurner Parts MAINTENANCE25Bad YesReplace Piezo Ignitor Turn on gas valve Replenish supply ReplaceGood Trouble ShootingCheck inlet pressure Replace ValveIs Pilot lit BadOrifice Size Optional Blower Label11 WC Input Btu/h 27,500 Converted ByDateHarman Gold Warranty Harman Gold WarrantyYear Transferable Limited Warranty Residential Year Limited Warranty Commercial