Harman Stove Company Conquest Gas Stove Installation Options, Connecting the Optional Thermostat

Page 18

Only For Qualified Installers

Thermostat

INSTALLATION (Options)

18

 

Connecting the Optional Thermostat

 

 

If the optional thermostat is used, it must be

 

plugged into the TH terminals located on the

 

 

valve.

 

 

 

When installing a millivolt control system, use

 

only a special low resistance thermostat. DO NOT

 

USE A REGULAR HEATING THERMOSTAT.

 

 

Be sure that all electrical connections are clean,

 

free from corrosion, and tight. Inspect connections

 

periodically to confirm that no corrosion has built

 

up over time.

 

 

 

When properly installed and maintained, a mil-

 

livolt control system should give many years of

 

trouble-free service.

 

 

 

It is important to use wire of a gauge proper

 

for the length of the wire:

 

 

RECOMMENDED WIRE GAUGES

 

 

Maximum

Wire

 

 

Length

Gauge

 

 

100'

14

 

Burner Button

60'

16

 

40'

18

 

 

25'

20

 

 

15'

22

 

Remote Control Kit

The button on the remote control can be used to turn the fire on and off.

This remote uses the ultrasonic control method and does not need to be pointed directly at the fire- place.

The kit includes installation instructions, a hand held sending unit, receiving unit, mounting bracket, and all wiring.

Note: The ON/OFF switch must be “OFF” when using the remote. If the switch is in the “ON”

position, the fire will stay on even when the set tem- perature on the thermostat is reached.

Glass Grill

To install the glass grill remove the door and slide the top of the vertical bars up into the slots at the top of the firebox opening. Lower the grill down so the bottom of the vertical bars rest just inside the lip at the bottom of the firebox opening.

Reinstall door.

Glass Grill

Image 18 Contents
Safety Notice Harman Conquest Gas StoveFor Your Safety What to do if YOU Smell GAS Table of Contents Introduction4 OPERATION5 OperationOPERATION6 Pilot FlamesSPECIFICATIONS7 Ratings NaturalSpecifications Corner ClearancesAlcove Clearances Installation Use Only Approved Venting Part Numbers for SimpsonDura-Vent Pipe and Fittings8 x Description Conquest Rear VentRequirements for Terminating the Venting INSTALLATION13 Damper SettingsFeet Changing to Natural Gas Natural Gas Conversion KitNatural Gas Kit INSTALLATION15 Ember Placement INSTALLATION16Log Placement Deflector plateInstalling Tiles Tile KitInstallation Options Connecting the Optional ThermostatRemote Control Kit Optional Blower Removing the Glass Front MaintenanceCleaning the Glass Replacing the GasketCleaning the Burners MAINTENANCE21Cleaning the Log Set and Firebox Inspecting the VentingMAINTENANCE22 Optional Blower WiringDiagram 120 Volt Model Conquest WHI #Parts Glass gasket 7’/unitMAINTENANCE25 Burner PartsReplace Piezo Ignitor Turn on gas valve Replenish supply YesBad ReplaceCheck inlet pressure Trouble ShootingGood Replace ValveBad Is Pilot lit11 WC Optional Blower LabelOrifice Size Input Btu/h 27,500 Converted ByDateYear Transferable Limited Warranty Residential Harman Gold WarrantyHarman Gold Warranty Year Limited Warranty Commercial