INSERT INSTALLATION (CONT.) - For qualified installers only! PAGE 11
Insert Placement
Min.
Min.
The insert must be in place with the gas line and vent attached prior to installing the panels.
The Insert Must be
Placed 13" into the
Fireplace.
See the section "Gas Line Installation" for details on the location of the gas inlet.
Use the leveling bolts for fireplaces with recessed floors (included with the stove).
Run the power cord to either side of the insert along the facing.
¥Insert must be placed so no combustibles are within, or can swing within 36" of the front of the heater (e.g. drapes, doors)
¥The insert may be placed inside a masonry fireplace or listed
¥The insert must be installed in a level, undamaged fireplace (damage must be repaired prior to installation). Use the included leveling bolts to level the insert in fireplaces with recessed floors.
¥The insert must maintain 10" clearance to sidewalls (measure from the upper top)
¥
¥Combustible mantles must be a minimum
Floor Protection
¥The heater must be installed on a
Zero-Clearance (Metal) Fireplace Requirements:
¥The damper ("A") and grate (with logset) ("B") must be removed (see the illustration below)
¥The smoke shelf ("C"), internal baffles ("D"), screen ("E"), masonry lining or refractory ("G" & "I"), and metal or glass doors ("F") may be removed (if applicable)
¥The insulation ("H"), and any structured rigid frame members (metal sides, floor, door frame, face of the fireplace, etc.) may not be removed or altered
|