INSERT INSTALLATION (CONT.) - For qualified installers only! PAGE 11

Insert Placement

Min. 29-3/4" WIde (includes 6" for gas line installation)

Min. 22-1/8" Tall (includes 2" for vent installation)

The insert must be in place with the gas line and vent attached prior to installing the panels.

The Insert Must be

Placed 13" into the

Fireplace.

See the section "Gas Line Installation" for details on the location of the gas inlet.

Use the leveling bolts for fireplaces with recessed floors (included with the stove).

Run the power cord to either side of the insert along the facing.

¥Insert must be placed so no combustibles are within, or can swing within 36" of the front of the heater (e.g. drapes, doors)

¥The insert may be placed inside a masonry fireplace or listed zero-clearance (metal) fireplace

¥The insert must be installed in a level, undamaged fireplace (damage must be repaired prior to installation). Use the included leveling bolts to level the insert in fireplaces with recessed floors.

¥The insert must maintain 10" clearance to sidewalls (measure from the upper top)

¥Non-combustible facing (e.g. brick, tile) must extend 8" minimum from the side and 8" to the top of the insert (measure from the upper top)

¥Combustible mantles must be a minimum 17-1/2" above the top of the insert (measure from the upper top)

Floor Protection

¥The heater must be installed on a non-combustible hearth and may not extend over combustible flooring

Zero-Clearance (Metal) Fireplace Requirements:

¥The damper ("A") and grate (with logset) ("B") must be removed (see the illustration below)

¥The smoke shelf ("C"), internal baffles ("D"), screen ("E"), masonry lining or refractory ("G" & "I"), and metal or glass doors ("F") may be removed (if applicable)

¥The insulation ("H"), and any structured rigid frame members (metal sides, floor, door frame, face of the fireplace, etc.) may not be removed or altered

 

 

H

 

F

 

C

A

 

 

 

 

 

D

 

E

 

I

 

 

 

 

 

B

G

 

 

 

Image 11
Contents Chelan B-Vent ¥ if YOU Smell GAS 2 Safety PrecautionsSafety Precautions 4 Table of Contents Dimensions Features and SpecificationsInstallation Options Features Heating SpecificationsItems Packed with the Chelan 700 B-Vent Installation PreparationItems Required for Installation Order of InstallationGas Inlet Pressure Heater Placement RequirementsGas Line Installation Floor ProtectionElectrical Connection Vent RequirementsVent Termination Requirements Items Packed with the Heater Re-Routing the Power Cord to the Front10 Insert Installation CONT. For qualified installers only Insert Must be Placed 13 into Fireplace Insert PlacementFuel Gas Line InstallGas Line Connection Zero Clearance Ember Installation 14 Finalizing the InstallationLog Installation Twig InstallationHeater. Leak test all Finalizing the Installation CONT.Gas Control Valve 16 Operating Your HeaterBefore You Begin Location of Controls See explanation belowStarting The Pilot Flame Operating Your HeaterTurning the Heater On and Off Adjusting the Flame Height18 Operating Your Heater Starting the Heater for the First TimePilot Flame Adjusting the Blower SpeedNormal Operating Sounds BlowerMaintaining Your Stoves Appearance Yearly Service Procedure20 Maintaining Your Heater Until You TroubleshootingProblem Possible Cause What Prevents Gas Buildup 22 TroubleshootingHow this Heater Works What Turns the Main Burners On and OffWiring Diagram Why Nothing Should Be Placed Against the HeaterYears 1 & 2 Coverage Parts & Labor 24 WarrantyTM B-VENT Listing Information26 Optional Equipment Pedestal InstallationTelescoping Leg Installation Part number Optional Equipment Surround Panel InstallationRobertshaw 28 Optional EquipmentOutside Air Kit Remote ThermostatPropane Conversion Kit Items Needed For AssemblyInstallation Instructions 30 Optional EquipmentOptional Equipment Orifice Identification 32 Optional EquipmentOFF 34 Index