PAGE 32 OPTIONAL EQUIPMENT (CONTINUED)

4Follow the directions below to remove the natural gas orifice. Apply thread sealant to the LP orifice (#49 - it has "49" stamped on it) and tighten in place with a 1/2" open end wrench. Replace the spring. Slide the adjustable shutter back in place.

a

b

Push the adjustable shutter to the

Slide the adjustable shutter

left, off the orifice (be careful not

down, away from the orifice.

to bend the shutter linkage).

 

Adjustable

 

Shutter

 

Orifice

 

c

Remove the spring

Shutter Linkage

d

Use a 1/2Ó open end wrench to unscrew the orifice.

1/2" Wrench

ef

 

The new LP orifice has

 

Ò49Ó stamped on it.

 

Apply thread

49

sealant to the

new orifice

prior to installation.

The old NG orifice has Ò31Ó stamped on it.

31

5Re-attach the burner pan and burner box front to the burner pan box following the instructions in step 3 in reverse order.

6Remove the pilot orifice following the instructions below. Replace with the propane pilot orifice. The propane conversion kit includes a .016Ó (labeled LP 16) or .011Ó (labeled LP 11) pilot orifice. The .016Ó orifice is preferred because it allows for greater pilot adjustment.

Remove the pilot

hood assembly by unscrewing the two attachment screws.

Phillips

Screwdriver

Pull the pilot orifice

retainer and pilot orifice

upwards to remove.

Pilot Hood

Assembly

Orifice Identification:

Pilot Orifice

LP (Propane) Orifices

 

 

 

 

 

Retainer

 

L

 

L

 

1

1

1

6

 

 

P

 

P

Pilot Orifice

 

 

 

 

 

 

 

(preferred)

 

NG (Natural Gas) Orifices

 

1

8

2

1

 

 

N

 

N

(preferred)

Image 32
Contents Chelan B-Vent 2 Safety Precautions ¥ if YOU Smell GASSafety Precautions 4 Table of Contents Features and Specifications Installation Options FeaturesHeating Specifications DimensionsInstallation Preparation Items Required for InstallationOrder of Installation Items Packed with the Chelan 700 B-VentHeater Placement Requirements Gas Line InstallationFloor Protection Gas Inlet PressureElectrical Connection Vent RequirementsVent Termination Requirements Re-Routing the Power Cord to the Front Items Packed with the Heater10 Insert Installation CONT. For qualified installers only Insert Placement Insert Must be Placed 13 into FireplaceFuel Gas Line InstallGas Line Connection Zero Clearance 14 Finalizing the Installation Log InstallationTwig Installation Ember InstallationFinalizing the Installation CONT. Heater. Leak test all16 Operating Your Heater Before You BeginLocation of Controls See explanation below Gas Control ValveOperating Your Heater Starting The Pilot FlameAdjusting the Flame Height 18 Operating Your HeaterStarting the Heater for the First Time Turning the Heater On and OffAdjusting the Blower Speed Normal Operating SoundsBlower Pilot FlameMaintaining Your Stoves Appearance Yearly Service Procedure20 Maintaining Your Heater Until You TroubleshootingProblem Possible Cause 22 Troubleshooting How this Heater WorksWhat Turns the Main Burners On and Off What Prevents Gas BuildupWhy Nothing Should Be Placed Against the Heater Wiring Diagram24 Warranty Years 1 & 2 Coverage Parts & LaborListing Information TM B-VENT26 Optional Equipment Pedestal InstallationTelescoping Leg Installation Part number Surround Panel Installation Optional Equipment28 Optional Equipment RobertshawRemote Thermostat Outside Air KitItems Needed For Assembly Installation Instructions30 Optional Equipment Propane Conversion KitOptional Equipment 32 Optional Equipment Orifice IdentificationOFF 34 Index