LISTING INFORMATION PAGE 25
The safety label can be found on the rear panel. A copy is shown below.
Tested & |
| Beaverton, | 700 |
| |||
Listed by |
| OR. USA | TM |
|
Listed Gas-Fired Vented Room Heater
Tested to ANSI
By OMNI Environmental Services (Report
Must be installed in accordance with all local codes, if any; if not, follow ANSI Z223.1 in USA, CAN B149 in Canada, and the requirements listed in the accompanying owner's manual.
Electrical connections and grounding must be installed in accordance with local codes, if any; if not, follow ANSI/NFPA 70 in USA or CSAC 2.21 in Canada.
Controls: Robertshaw Model
This room heater is equipped at the factory for use with natural gas, if conversion to propane (LP) fuel is desired, the optional factory conversion kit #98900745 must be used.
Input and Orifice Specifications: | L.P. | N.G. |
Maximum Input Rating (BTU/Hr) | 38,000 | 40,000 |
Minimum Input Rating (BTU/Hr) | 20,000 | 23,000 |
Front Burner Orifice (DMS) | #49 | #31 |
Pressure Specifications: | L.P. | N.G. |
|
|
|
Manifold Pressure HI Setting (in W.C.) | 10Ó | 3.5Ó |
Manifold Pressure LO Setting (in W.C.) | 2.7Ó | 1.0Ó |
Minimum Inlet Pressure (in W.C.) | 11Ó | 5.5Ó |
Minimum Clearance to Combustibles |
|
|
Unit to Sidewall | 10 | " |
Unit to Backwall | 4 | " |
Unit to Cornerwall | 4 | " |
Side Facing to Unit | 8 | " |
Top Facing to Unit | 8 | " |
Alcove Minimum Width | 44 | " |
Alcove Minimum Height | 58 | " |
Alcove Maximum Depth | 45 | " |
Front of Unit | 36 | " |
Mantle Height Above Unit | 17.5 | " |
Hearth Extension Front | 0 | " |
Hearth Extension Sides | 0 | " |
Use only with ÒBÓ vent listed chimney
Blower Electrical Rating: 115 Volts, 1.5 Amps, 60 Hz. | FAN TYPE VENTED CIRCULATOR |
WARNING:
Operation of this heater when not connected to a properly installed and maintained venting system of tampering with the vent safety shutoff system can result in carbon monoxide (CO) poisoning and possible death.
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the information in the owner's manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
Risk of electrical shock. Disconnect power before servicing unit.
This room heater needs fresh air for safe operation and must be installed with provisions for adequate combustion and ventilation air. See ownerÕs installation and operating instructions.
Manufacture |
|
| 1997 |
|
|
| Jan. |
|
|
| Apr. |
|
|
| Jul. |
|
|
| Oct. |
|
Date: |
|
| 1998 |
|
|
| Feb. |
|
|
| May |
|
|
| Aug. |
|
|
| Nov. | 10850 117th Pl. N.E. Kirkland, WA 98033 |
|
|
|
|
| ||||||||||||||||
|
|
| 1999 |
|
|
| Mar. |
|
|
| Jun. |
|
|
| Sep. |
|
|
| Dec. | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| DO NOT REMOVE THIS LABEL |
|
|
| MADE IN U.S.A. |