Avalon Stoves 1190 Hearth Stove Direct Connection, Interior or Exterior Masonry Chimney

Page 16

16

Stove Installation (for qualified installers only)

Hearth Stove Direct Connection

NOTE:

Direct connections require installation of an airtight, non-combustible block-off plate or damper adapter

Interior or Exterior Masonry Chimney

NOTE:

This type of installation requires a UBC approved masonry connector or a factory built (U.L. Listed) wall thimble.

NOTE: The chimney must have a clay tile liner. If it does not, the installation must use a positive connection (full reline). The entire fireplace and chimney must be clean, undamaged, and meet all local building codes (UBC, etc.). Damage must be repaired prior to installation. The chimney must be 15' to 33' tall.

Max. 8”

Combustible Mantle

Min. 18"

Floor Protection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(See the section "Floor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Protection Requirements"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for more details)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: The chimney must have a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

clay tile liner. If it does not, the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

installation must use a positive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

connection (full reline). The

 

 

 

 

 

 

 

 

 

 

 

 

 

 

entire fireplace and chimney must

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

be clean, undamaged, and meet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

all local building codes (UBC,

 

 

Min. 18"

 

 

 

 

 

 

etc.). Damage must be repaired

 

 

 

 

 

 

 

 

 

clearance

 

 

 

 

 

 

prior to installation. The chimney

 

 

 

 

 

 

 

 

 

to ceiling

 

 

 

 

 

 

must be 15' to 33' tall.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

See the section "Stove

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Placement Requirements" for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

minimum clearances required.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Chimney connector sections

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clay

Liner

Stainless steel chimney connector must Extend 1' past the block-off plate or to the flue liner

Airtight

Insulated

Clean-Out

Remove damper or wire it open

Block-off plate or damper adapter

See the section "Stove Placement Requirements" for minimum clearances required.

Figure 14

Clay Liner

This type of installation requires a UBC approved masonry connector or a factory built (U.L. Listed) wall thimble.

See the section

"Floor Protection

Requirements"

Make sure the clean-out seals in place.

Figure 15

© Travis Industries

93508061

4050526

Image 16
Contents Olympic Introduction Important Information 2IntroductionSave Your Bill of Sale Table of Contents Safety Precautions AshesTravis Industries, Inc. grants no warranty, implied or MobileFeatures & Specifications Planning The Installation Preparation for InstallationAdditional Accessories Needed for Installation Stove Installation ConsiderationsStove Placement Requirements Minimum Clearance Singlewall Reduced ConnectorFloor Protection Requirements ClearancesTop View Straight Installation Top View Corner InstallationDrafting Chimney RequirementsPerformance Chimney Termination Requirements Outside Air RequirementsAlcove Installation Requirements Not the connector manufacturers clearance Mobile Home RequirementsStandard Ceiling with a Factory Built Chimney Cathedral Ceiling with a Factory Built ChimneyExterior Factory Built Chimney Hearth Stove Positive ConnectionHearth Stove Direct Connection Interior or Exterior Masonry ChimneyStandard vs. Cook-Top Installations Installation ConsiderationsTop Air Chamber Extension Fireplace Size Fireplace RequirementsHearth Requirements Insert Placement RequirementsMasonry Fireplace Requirements Leveling Bolt Installation Drafting PerformanceBlock-Off Plate Installation Block-Off Plate TemplateInsert with Positive Connection Insert with Direct Connection Masonry FireplaceInsert with Face Seal Connection Safety Notice Operating Your ApplianceBefore Your First Fire Opening the DoorBypass Operation Starting a Fire Approximate Air Control Settings Adjusting the Burn RateAsh Removal Optional Blower Operation Re-Loading the StoveOvernight Burn Normal Operating SoundsWhy Dry Wood is Key Hints for BurningSelecting Wood Wood Cutting and StorageTroubleshooting Daily Maintenance while stove is in use Clean the Glass if necessaryMaintaining Your Appliance Remove Ash if necessaryDoor and Glass Inspection Monthly Maintenance while appliance is in useCreosote Formation and Need for Removal Yearly Maintenance Cleaning the Air Duct and Blower if applicableTouch Up Paint Firebrick and Baffle InspectionDoor Parts Replacing the GlassReplacing the Door Gasket Replacing the Door HandleFloor and Side Firebrick Removal & Replacement Firebox PartsBaffle Removal & Replacement Air Tube Removal & ReplacementLimited 7 Year Warranty Years 1 & 2 Coverage Parts & LaborYears 3 Through 5 Coverage Parts & Labor Years 6 & 7 Coverage Parts onlyListing Information Listing LabelOptional Equipment PedestalOutside Air Installation for wood stoves only Outside AIR EquipmentRear Blower Installation Part number Install the wire clip following the directions belowOutside Air Boot Installation Part number Surround Panels see s below Z e Size on Insert w trimTo Switch the Power Cord to the Left Side Front BlowerIndex

1190 specifications

Avalon Stoves has long been recognized for its commitment to quality, efficiency, and performance in the realm of home heating. Among its stellar offerings, the Avalon Stoves 1190 stands out as a testament to modern innovation and classic design. This wood-burning stove caters to both functionality and aesthetics, making it an ideal addition to any home.

One of the main features of the Avalon 1190 is its impressive heating capacity. With the ability to produce up to 70,000 BTUs, this stove is capable of heating large spaces, making it perfect for open-concept layouts or larger living areas. The stove's firebox is designed to accommodate logs up to 18 inches, allowing for longer burn times and less frequent reloading.

In addition to its heating capabilities, the Avalon 1190 incorporates advanced technologies that enhance its efficiency. One notable feature is the clean-burn technology, which significantly reduces emissions while maximizing heat output. This technology not only promotes a healthier environment but also aligns with eco-friendly practices, creating a more sustainable heating option for homeowners.

The Avalon 1190 is also equipped with a secondary combustion system, which ensures that more of the wood’s energy is utilized during the burn process. This results in hotter fires and minimal smoke production, further contributing to its efficient performance. The stove's design also includes a built-in air wash system that helps keep the glass clean, allowing for a clear view of the mesmerizing flames.

Another characteristic that sets the Avalon 1190 apart is its aesthetic appeal. With a sleek and contemporary design, the stove is available in several finishes, including classic black, cast iron, and even a stylish porcelain enamel. This versatility ensures that it can seamlessly integrate into any home décor, from rustic to modern settings.

Moreover, the Avalon 1190 comes with a reliable warranty, underscoring the manufacturer's confidence in the product’s durability. Constructed with high-quality materials, this wood stove is built to last, providing warmth and comfort for years to come.

In conclusion, the Avalon Stoves 1190 is a perfect blend of high performance, innovative technology, and elegant design. Whether it’s for heating a cozy living room or creating an inviting ambiance, the Avalon 1190 remains a top choice for discerning homeowners seeking a dependable wood-burning solution. Its efficient heating capabilities, coupled with eco-friendly features, make it a model of contemporary living that respects both comfort and the environment.