Fireplace Insert Installation (for qualified installers only)

Block-Off Plate Installation

Whenever this appliance is installed with a direct connection a block-off plate, or other non-combustible seal-off device (e.g. damper adapter), will need to be installed. This device is used to seal the chimney, insuring no smoke enters the home and providing the chimney system with a seal to promote draft. The directions below detail the steps for construction and installation of a block-off plate.

Determine a location for the block-off plate at the top of the firebox below the damper area (make it high enough to allow installation of the connection pipe). The location should be level and in an area where it can be mounted easily. Measure the width at the rear ("A") and front ("B") of the firebox at the height where the block-off plate will be installed (see Figure 19). Then measure the depth of the location where the block-off plate will be installed ("C").

Make a cardboard template of the measurements, but add a 2" flange to each side. This flange will be used to mount the block-off plate to the inside of the firebox. Bend the flanges downwards on the template and place it inside the fireplace. If the template fits correctly in its planned location, go to the next step. If it does not, make a new template with the appropriate corrections until it fits correctly.

With the template in place, mark the location of the flue (see “Dimensions” on page 6). This location approximates the center of the flue when the insert is in place (a slight offset may occur based upon insert and block-off plate placement). Remove the template and cut a 6 1/4" diameter hole centered on this mark.

Make the block-off plate of 24 gage or thicker steel to match the template. Drill two holes in each flange for mounting the plate.

Mount the block-off plate using masonry screws.

Insulate the block-off plate using high-temperature fiberglass insulation (Kaowool® or equivalent) and furnace cement (allow the cement to dry for at least 24 hours before burning).

After placing the appliance and installing the pipe through the block-off plate, use high-temperature fiberglass insulation and furnace cement to seal any cracks between the pipe and block-off plate.

See the

dimensions to

determine the

location of the

center of the

flue.

 

Damper

B

 

C

A

Firebox

Block-Off Plate Template

2" Flanges

Measurement

(for attaching

"A"

the block-off

 

plate)

 

Measurement

"C"

Measurement "B"

See the dimensions to determine the location of the center of the flue.

Figure 19

© Travis Industries

93508061

4050526

Image 22
Contents Olympic Introduction Important Information 2IntroductionSave Your Bill of Sale Table of Contents Safety Precautions AshesTravis Industries, Inc. grants no warranty, implied or MobileFeatures & Specifications Additional Accessories Needed for Installation Planning The InstallationPreparation for Installation Stove Installation ConsiderationsFloor Protection Requirements Stove Placement RequirementsMinimum Clearance Singlewall Reduced Connector ClearancesTop View Straight Installation Top View Corner InstallationDrafting Chimney RequirementsPerformance Chimney Termination Requirements Outside Air RequirementsAlcove Installation Requirements Not the connector manufacturers clearance Mobile Home RequirementsStandard Ceiling with a Factory Built Chimney Cathedral Ceiling with a Factory Built ChimneyExterior Factory Built Chimney Hearth Stove Positive ConnectionHearth Stove Direct Connection Interior or Exterior Masonry ChimneyStandard vs. Cook-Top Installations Installation ConsiderationsTop Air Chamber Extension Fireplace Size Fireplace RequirementsHearth Requirements Insert Placement RequirementsMasonry Fireplace Requirements Leveling Bolt Installation Drafting PerformanceBlock-Off Plate Installation Block-Off Plate TemplateInsert with Positive Connection Insert with Direct Connection Masonry FireplaceInsert with Face Seal Connection Before Your First Fire Safety NoticeOperating Your Appliance Opening the DoorBypass Operation Starting a Fire Approximate Air Control Settings Adjusting the Burn RateAsh Removal Overnight Burn Optional Blower OperationRe-Loading the Stove Normal Operating SoundsSelecting Wood Why Dry Wood is KeyHints for Burning Wood Cutting and StorageTroubleshooting Maintaining Your Appliance Daily Maintenance while stove is in useClean the Glass if necessary Remove Ash if necessaryDoor and Glass Inspection Monthly Maintenance while appliance is in useCreosote Formation and Need for Removal Touch Up Paint Yearly MaintenanceCleaning the Air Duct and Blower if applicable Firebrick and Baffle InspectionReplacing the Door Gasket Door PartsReplacing the Glass Replacing the Door HandleFloor and Side Firebrick Removal & Replacement Firebox PartsBaffle Removal & Replacement Air Tube Removal & ReplacementYears 3 Through 5 Coverage Parts & Labor Limited 7 Year WarrantyYears 1 & 2 Coverage Parts & Labor Years 6 & 7 Coverage Parts onlyListing Information Listing LabelOptional Equipment PedestalOutside Air Installation for wood stoves only Outside AIR EquipmentRear Blower Installation Part number Install the wire clip following the directions belowOutside Air Boot Installation Part number Surround Panels see s below Z e Size on Insert w trimTo Switch the Power Cord to the Left Side Front BlowerIndex

1190 specifications

Avalon Stoves has long been recognized for its commitment to quality, efficiency, and performance in the realm of home heating. Among its stellar offerings, the Avalon Stoves 1190 stands out as a testament to modern innovation and classic design. This wood-burning stove caters to both functionality and aesthetics, making it an ideal addition to any home.

One of the main features of the Avalon 1190 is its impressive heating capacity. With the ability to produce up to 70,000 BTUs, this stove is capable of heating large spaces, making it perfect for open-concept layouts or larger living areas. The stove's firebox is designed to accommodate logs up to 18 inches, allowing for longer burn times and less frequent reloading.

In addition to its heating capabilities, the Avalon 1190 incorporates advanced technologies that enhance its efficiency. One notable feature is the clean-burn technology, which significantly reduces emissions while maximizing heat output. This technology not only promotes a healthier environment but also aligns with eco-friendly practices, creating a more sustainable heating option for homeowners.

The Avalon 1190 is also equipped with a secondary combustion system, which ensures that more of the wood’s energy is utilized during the burn process. This results in hotter fires and minimal smoke production, further contributing to its efficient performance. The stove's design also includes a built-in air wash system that helps keep the glass clean, allowing for a clear view of the mesmerizing flames.

Another characteristic that sets the Avalon 1190 apart is its aesthetic appeal. With a sleek and contemporary design, the stove is available in several finishes, including classic black, cast iron, and even a stylish porcelain enamel. This versatility ensures that it can seamlessly integrate into any home décor, from rustic to modern settings.

Moreover, the Avalon 1190 comes with a reliable warranty, underscoring the manufacturer's confidence in the product’s durability. Constructed with high-quality materials, this wood stove is built to last, providing warmth and comfort for years to come.

In conclusion, the Avalon Stoves 1190 is a perfect blend of high performance, innovative technology, and elegant design. Whether it’s for heating a cozy living room or creating an inviting ambiance, the Avalon 1190 remains a top choice for discerning homeowners seeking a dependable wood-burning solution. Its efficient heating capabilities, coupled with eco-friendly features, make it a model of contemporary living that respects both comfort and the environment.