Avalon Stoves Cedar EF manual Safety Label, Minimum Clearances to Combustibles, Dec.0398

Page 31

Safety Label

29

The listing label is shown below for your records. It can be found inside the left side panel.

Cedar DVS FS

Report No. 028-S-38-5

Listed Vented

Gas Fireplace Heater

Tested and certified by OMNI-Test Laboratories, Inc. to the combustion performance and construction requirements of ANSI Z21.88b-1999, and applicable sections of UL 307b.

The Cedar is equipped from the factory only for use with Natural Gas. For conversion to LP (Propane) use kit supplied by the manufacturer. This appliance must be installed in accordance with all local codes, if any; if not, in USA follow ANSI Z223.1-1992 and NFPA 54(88). Installation in Manufactured or Mobile Homes must conform with: In USA, Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280. This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See owner’s manual for details. This appliance is not convertible for use with other gases, unless a certified kit supplied by the manufacturer is used. See owner’s manual for information on making these changes. This appliance uses a millivolt- type control system consisting of a gas control valve/regulator, a standing pilot burner assembly, a thermopile, a thermocouple, a piezo ignitor, and the ON/OFF switch. THIS UNIT DOES NOT REQUIRE 110 VOLT POWER TO OPERATE. All exhaust gases must be vented outside the structure of the living-area. Combustion air is drawn from outside the living-area structure.

This appliance is a Vented Gas Fireplace Heater. Not for use with Solid Fuel.

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier.

WARNING: Operation of this appliance when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death.

Installation and repair should be performed by a qualified service person. The appliance should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required where excessive lint from material like carpeting and bedding is present. The control compartment, the burner compartment and all circulating air passageways of the appliance must be kept clean and clear at all times.

This appliance must be properly connected to a venting system in accordance with the manufacturer’s installation instructions. This vented gas fireplace heater is not for use with air filters.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid flesh burns or clothing ignition. Young children should be carefully supervised at all times when they are in the same room as the appliance.

CAUTION:Hot while in operation. Do not touch. Keep children, clothing, furniture, gasoline and other liquids having flammable vapors away.

CAUTION:Do not operate this appliance with glass removed, cracked or broken. Replacement of the panel(s) should be done by a licensed or qualified service person.

Use direct vent systems listed in owner’s manual to vent this appliance to the exterior.

Minimum Clearances to Combustibles

Unit to Sidewall

10” / 255mm

Alcove Min. Height

60” / 1520mm

 

Unit to Backwall

5” / 125mm

Alcove Max. Depth

48” / 1220mm

 

Unit to Cornerwall

5” / 125mm

Alcove Min Width

42.5” / 1080mm

 

Front of Unit

36” / 910mm

 

 

 

 

 

 

 

 

 

 

FAN TYPE VENTED CIRCULATOR

 

 

 

 

Blower Electrical Rating: 115V., 1.5 Amps, 60 Hz, 150 Watts

 

 

 

 

 

 

 

 

 

 

 

L.P.

N.G.

 

 

L.P.

N.G.

Input Rate on “HI” (BTU/Hr) . . .

. . . . 31,000

31,000

Minimum Inlet Pressure (inches W.C.)

. . . . . . . .

11.5”

5.5”

Input Rate on “LO” (BTU/Hr) . .

. . . . 18,500

23,276

Maximum Inlet Pressure (inches W.C.)

. . . . . . . .

13”

7”

 

 

 

Manifold Pressure on “HI” (inches W.C.)

11”

3.5”

In USA, this appliance is equipped for installation from 0-2000 ft. (0-610 m). For altitudes above 2,000 feet, the vent configuration, orifice, or combination of both may need to be changed. See owner’s manual for information on making these changes.

Manufacture Date:

2000

2001

2002

Jan.

Feb.

Mar.

Apr.

May

Jun.

Jul.

Aug.

Sep.

Oct.

Nov.

10850 117th Pl. N.E. Kirkland, WA 98033

Dec.0398

Travis Industries

4 1 2 2 1 0 4

9 3 5 0 8 1 1 7

Image 31
Contents Cedar Manual Page Introduction Important Information Introduction1Travis Industries 2 2 1 0 5 0 8 1 1 Safety Precautions This Manual Table of Contents Specifications5 Stove Clearances Installation WarningsInstallation Preparation Packing ListGas Inlet Pressure Heater Placement RequirementsGas Line Installation Floor Protection RequirementsManuafacturer R i e s Vent RequirementsT E Approved Vent ConfigurationsRestrictor Position Measuring Vent LengthsPosition # Vertical Terminations with 0, 2, or 4 45 OffsetsOffset Length Hor. Offset Vert. Rise RestrictorHorizontal Terminations with One 90 Elbow Restrictor Restrictor Position # 5feet 10feet 15feet 20feet Restrictor Position # Vertical Terminations with Two 90 ElbowsRise every 12 of travel PositionTermination Requirements see the illustration below Finalizing the Installation Correct Opening the Door Log Set and Coal Installation Gas Control Valve Safety NoticeOperation21 LocationStarting The Pilot Flame 22OperationTurning the Heater On and Off Adjusting the Flame HeightOperation23 Starting the Heater for the First TimeNormal Operating Odors Optional Blower Adjusting the Speed24Operation Normal Operating SoundsCleaning Your Heater Maintenance25Yearly Service Procedure Troubleshooting Steps 26MaintenanceWhat Prevents Gas Buildup Maintenance27How this Heater Works What Turns the Main Burners On and OffWiring Diagram 28MaintenanceReplacement Parts Dec.0398 Safety LabelMinimum Clearances to Combustibles 2000 2001 2002 Jan Feb Mar Apr May Jun Jul Aug Sep Oct NovYears 6 & 7 Coverage Parts only Limited 7 Year WarrantyYears 1 & 2 Coverage Parts & Labor Years 3 Through 5 Coverage Parts & LaborLP Conversion Instructions Optional EquipmentSliding it to the left 32Optional EquipmentPlace Nutdriver From the air shutter byOff the pilot Fireback 34Optional EquipmentBack Stove Blower36Optional Equipment Gold Trivet Before installing the ventGold Door Gold GrillAddendum #1 Class a Chimney Conversion Kit 38Installation AddendaStandard Masonry Fireplace Installation AddendaAddendum #2 Interior Masonry Chimney Conversions Interior Masonry Chimney40Index

Cedar EF specifications

The Avalon Stoves Cedar EF is a stunning example of modern wood burning technology, designed to combine efficiency, performance, and aesthetic appeal. This stove is perfect for anyone looking to enhance their home with both heat and style, bringing the warmth of a real fire to living spaces while keeping energy costs in check.

At the heart of the Cedar EF is its advanced combustion technology. The stove features a clean-burning design that ensures maximum efficiency and minimal emissions. With an EPA-certified efficiency rating, the Cedar EF produces a remarkable amount of heat from a small amount of wood, making it an environmentally friendly choice as well. This is particularly vital in today’s eco-conscious market, where reduced emissions are paramount.

One of the main features of the Avalon Cedar EF is its large viewing window, which is framed with elegant cast iron. This window not only provides a beautiful view of the flames but also allows for great heat output. The high-efficiency design ensures that heat is radiated effectively into the room. Additionally, the stove’s unique air wash system keeps the glass clean, ensuring an unobstructed view of the fire.

The Cedar EF is equipped with a simple and convenient operation. The user-friendly air control lever allows for easy adjustments to regulate the burn rate and heat output. This feature not only enhances comfort but also contributes to fuel efficiency by allowing users to tailor the fire’s intensity to their needs.

In terms of size, the Cedar EF is compact yet powerful, making it a great fit for a variety of spaces. It is designed to be installed in both traditional and contemporary homes, blending seamlessly with various decor styles. The stove’s sleek design is complemented by a variety of options for finishes, including classic black, strapping it into a modern aesthetic.

For added versatility, the Avalon Cedar EF is designed to be a versatile heating solution and can be installed as a freestanding model or in an alcove. This flexibility allows homeowners to configure their heating sources according to their space.

Durability is also a key characteristic of the Cedar EF. Constructed from high-quality materials, this stove ensures longevity and consistent performance over time. Its robust design means that it can withstand the rigors of consistent use, delivering reliable warmth for years to come.

In summary, the Avalon Cedar EF combines cutting-edge technology with elegance and efficiency, making it a top choice for homeowners looking to add a cozy and stylish heating solution to their home. From its advanced clean-burning technology to its stunning design, the Cedar EF stands out as a leader in the wood stove market.