Burnham BH, BV manual Field Installed Options for Vertical Models only, Description

Page 22

D.FIELD INSTALLED OPTIONS FOR VERTICAL MODELS ONLY

Cone-Jet

The cone-jet allows the unit's discharged air to be adjusted from a direct high velocity stream to a broadened

stream that can cover a larger area.

 

Part No

Description

 

 

BVCJ-01

Cone Jet RV-42, 59

BVCJ-02

Cone Jet RV-78, 95

BVCJ-03

Cone Jet RV-139, 161

BVCJ-04

Cone Jet RV-193, 212

BVCJ-05

Cone Jet RV-247, 279

BVCJ-06

Cone Jet RV-333, 385

BVCJ-07

Cone Jet RV-500

BVCJ-08

Cone Jet RV-610

 

 

Truncone

The truncone allows for a broad air stream covering a larger area than possible with a cone-jet.

Part No

Description

 

 

BVTC-01

Truncone RV-42, 59, 78, 95

BVTC-02

Truncone RV-139, 161, 193, 212

BVTC-03

Truncone RV-247, 279, 333, 385

BVTC-04

Truncone RV-500, 610

 

 

One-Way Louver

The one-way louver allows for a one directional discharge of air.

Part No

Description

 

 

BV1L-01

One-Way Louver RV-42, 59

BV1L-02

One-Way Louver RV-78, 95

BV1L-03

One-Way Louver RV-139, 161

BV1L-04

One-Way Louver RV-193, 212

BV1L-05

One-Way Louver RV-247, 279

BV1L-06

One-Way Louver RV-333, 385

BV1L-07

One-Way Louver RV-500

BV1L-08

One-Way Louver RV-610

 

 

Two-Way Louver

The two-way louver allows for a one directional discharge of air.

Part No

Description

 

 

BV2L-01

Two-Way Louver RV-42, 59

BV2L-02

Two-Way Louver RV-78, 95

BV2L-03

Two-Way Louver RV-139, 161

BV2L-04

Two-Way Louver RV-193, 212

BV2L-05

Two-Way Louver RV-247, 279

BV2L-06

Two-Way Louver RV-333, 385

BV2L-07

Two-Way Louver RV-500

BV2L-08

Two-Way Louver RV-610

 

 

3-Cone Anemostat

The 3-cone anemostat allows for an even air stream covering a larger area than possible with the truncone.

Part No

Description

 

 

BV3A-01

3-Cone Anemostat RV-42, 59

BV3A-02

3-Cone Anemostat RV-78, 95

BV3A-03

3-Cone Anemostat RV-139, 161

BV3A-04

3-Cone Anemostat RV-193, 212

BV3A-05

3-Cone Anemostat RV-247, 279

BV3A-06

3-Cone Anemostat RV-333, 385

BV3A-07

3-Cone Anemostat RV-500

BV3A-08

3-Cone Anemostat RV-610

4-Cone Anemostat

The 4-cone anemostat allows for an even air stream covering a larger area than possible with the 3-cone

anemosat.

 

Part No

Description

 

 

BV4A-01

4-Cone Anemostat RV-42, 59

BV4A-02

4-Cone Anemostat RV-78, 95

BV4A-03

4-Cone Anemostat RV-139, 161

BV4A-04

4-Cone Anemostat RV-193, 212

BV4A-05

4-Cone Anemostat RV-247, 279

BV4A-06

4-Cone Anemostat RV-333, 385

BV4A-07

4-Cone Anemostat RV-500

BV4A-08

4-Cone Anemostat RV-610

 

 

22

Image 22
Contents BH and BV Unit Heaters 8144A001R4-2/07Table of Contents Important Information Read Carefully Before Installation III. Installation II. General InformationWiring Instructions Unit Heater Mounting Height115V / 60Hz / 1PH Wiring Schematic Recommended Maximum Mounting Height Hot Water System PipingPrior to Operation IV. OperationInitial START-UP Motors MaintenanceInspect Regularly CasingsTypical BH Unit Arrangement Sound Class Ratings VI. Application GuidelinesGeneral Guidelines Large Factories, Fabrication ShopsSteam Performance Data -- High Motor Speed Steam Performance DataSteam Performance Data -- Reduced Motor Speed Application Procedure Selection Procedure Steam ApplicationGiven Design Conditions Steam Calculation Formulas Fata = Eata + AtraUnit Entering Steam Correction FactorsSteam Heating Capacity Conversion Factors Heater Air Temp Types 100 125 150Steam Pressure Psig Air Temperature Rise Conversion FactorsSteam Unit Heater Mounting Height Correction Factors Correction FactorGauge Temp Latent Heat Properties of SteamBtu/lb Hot Water Performance Data -- High Motor Speed Hot Water Performance Data -- Reduced Motor SpeedWater Flow Rate Selection Procedure HOT Water ApplicationWater Temperature 125,020 Btu/hr Final AirHOT Water Calculation Formulas BtuAG = BtuS or BtuA x Glycol Correction FactorEthylene Glycol Correction Factors HOT Water Correction FactorsHot Water Heating Capacity Conversion Factors Hot Water Unit Heater Mounting Height Correction FactorsField Installed Options for Horizontal Models only VII. OPTIONS, Accessories and Control SequencesField Installed Options for Horizontal and Vertical Models Control SequencesField Installed Options for Vertical Models only DescriptionVertical Air Outlet Accessory Dimensions Vertical Air Outlet Accessory Maximum Height and Spread123 Cone-JetLou Truncone No Deflector AnemoBH Dimensional Data VIII. Dimensional DataModel BH Dimensions Model BV Dimensions BV Dimensional DataMale NPT Fan Ship Model IX. Motor Data Motor/Power CodesMotor/Power Description Code Voltage and Motor TypeLimited Warranty