Burnham BH, BV manual Properties of Steam, Gauge Temp Latent Heat, Btu/lb

Page 16

Table 8: Properties of Steam

Gauge

Temp

Latent Heat

Gauge

Temp

Latent Heat

Gauge

Temp

Latent Heat

Gauge

Temp

Latent Heat

Pressure

Pressure

Pressure

Pressure

(PSIG)

(°F)

(Btu/lb.)

(PSIG)

(°F)

(Btu/lb.)

(PSIG)

(°F)

(Btu/lb.)

(PSIG)

(°F)

(Btu/lb.)

 

 

 

 

 

 

 

 

0

212.0

970.3

34

279.4

924.7

70

316.0

897.3

109

343.6

875.4

2

218.5

966.2

36

281.9

922.9

72

317.7

896.0

112

345.4

873.9

4

224.4

962.4

38

284.3

921.1

74

319.3

894.8

115

347.2

872.5

5

227.2

960.6

40

286.7

919.3

76

320.9

893.5

118

348.9

871.0

6

229.8

958.8

42

289.0

917.6

78

322.4

892.3

121

350.7

869.6

8

234.8

955.6

44

291.3

915.9

80

323.9

891.1

124

352.4

868.2

10

239.4

952.5

46

293.5

914.3

82

325.4

889.9

125

352.9

867.8

12

243.7

949.6

48

295.6

912.7

84

326.9

888.8

127

354.0

866.9

14

247.8

946.8

50

297.7

911.2

86

328.4

887.6

130

355.7

865.5

16

251.6

944.2

52

299.7

909.7

88

329.8

886.5

133

357.3

864.1

18

255.3

941.7

54

301.7

908.2

90

331.2

885.4

136

358.9

862.9

20

258.8

939.3

56

303.6

906.7

92

332.5

884.3

139

360.4

861.5

22

262.1

936.9

58

305.5

905.3

94

333.9

883.2

142

362.0

860.3

24

265.3

934.7

60

307.3

903.9

96

335.2

882.1

145

363.5

859.0

26

268.3

932.5

62

309.1

902.5

98

336.6

881.1

150

365.9

856.9

28

271.3

930.5

64

310.9

901.2

100

337.9

880.0

175

377.4

846.8

30

274.1

928.5

66

312.6

899.9

103

339.8

878.5

200

387.9

837.2

32

276.8

926.6

68

314.4

898.6

106

341.7

876.9

225

397.3

828.5

 

 

 

 

 

 

 

 

 

 

 

 

16

Image 16
Contents BH and BV Unit Heaters 8144A001R4-2/07Table of Contents Important Information Read Carefully Before Installation III. Installation II. General InformationWiring Instructions Unit Heater Mounting Height115V / 60Hz / 1PH Wiring Schematic Recommended Maximum Mounting Height Hot Water System PipingPrior to Operation IV. OperationInitial START-UP Maintenance Inspect RegularlyMotors CasingsVI. Application Guidelines General GuidelinesTypical BH Unit Arrangement Sound Class Ratings Large Factories, Fabrication ShopsSteam Performance Data -- High Motor Speed Steam Performance DataSteam Performance Data -- Reduced Motor Speed Application Procedure Selection Procedure Steam ApplicationGiven Design Conditions Steam Calculation Formulas Fata = Eata + AtraSteam Correction Factors Steam Heating Capacity Conversion FactorsUnit Entering Heater Air Temp Types 100 125 150Air Temperature Rise Conversion Factors Steam Unit Heater Mounting Height Correction FactorsSteam Pressure Psig Correction FactorGauge Temp Latent Heat Properties of SteamBtu/lb Hot Water Performance Data -- High Motor Speed Hot Water Performance Data -- Reduced Motor SpeedSelection Procedure HOT Water Application Water TemperatureWater Flow Rate 125,020 Btu/hr Final AirHOT Water Calculation Formulas BtuAG = BtuS or BtuA x Glycol Correction FactorHOT Water Correction Factors Hot Water Heating Capacity Conversion FactorsEthylene Glycol Correction Factors Hot Water Unit Heater Mounting Height Correction FactorsVII. OPTIONS, Accessories and Control Sequences Field Installed Options for Horizontal and Vertical ModelsField Installed Options for Horizontal Models only Control SequencesField Installed Options for Vertical Models only DescriptionVertical Air Outlet Accessory Dimensions Vertical Air Outlet Accessory Maximum Height and Spread123 Cone-JetLou Truncone No Deflector AnemoBH Dimensional Data VIII. Dimensional DataModel BH Dimensions Model BV Dimensions BV Dimensional DataMale NPT Fan Ship Model Motor/Power Codes Motor/Power Description CodeIX. Motor Data Voltage and Motor TypeLimited Warranty