IX. MOTOR DATA

HORIZONTAL AIR DELIVERY UNIT HEATER MOTOR DATA

 

 

 

 

 

 

 

Voltage and Motor Type

 

Motor Data

 

115/60/1

 

230/60/1

230/460/60/3

 

 

115/208 - 230/60/1

 

Totally Enclosed w/ Thermal Overload

Totally Enclosed

 

Explosion Proof

 

 

 

 

 

 

 

 

w/Thermal Overload

 

 

 

 

 

 

 

 

 

 

 

Model No.

Motor HP

 

 

 

 

 

Full Load Amps

 

BH-18

1/30

 

0.70

 

 

0.35

N/A

 

4.8/2.3-2.4

BH-24

1/30

 

0.70

 

 

0.35

N/A

 

4.8/2.3-2.4

BH-33

1/15

 

0.72

 

 

0.40

N/A

 

4.8/2.3-2.4

BH-47

1/15

 

0.72

 

 

0.40

N/A

 

4.8/2.3-2.4

BH-63

1/10

 

1.30

 

 

0.80

1.4/0.7

 

 

4.8/2.3-2.4

BH-86

1/10

 

1.30

 

 

0.80

1.4/0.7

 

 

4.8/2.3-2.4

BH-108

1/8

 

1.58

 

 

0.90

2.2/1.1

 

 

6.8/3.1-3.4

BH-121

1/8

 

1.58

 

 

0.90

2.2/1.1

 

 

6.8/3.1-3.4

BH-165

1/4

 

2.70

 

 

1.40

2.2/1.1

 

 

6.8/3.1-3.4

BH-193

1/4

 

2.80

 

 

1.40

2.2/1.1

 

 

6.8/3.1-3.4

BH-258

1/3

 

3.60

 

 

1.90

2.2/1.1

 

 

7.8/3.6-3.9

BH-290

1/2

 

4.70

 

 

2.40

2.2/1.1

 

 

9.6/4.7-4.8

BH-340

1/2

 

4.70

 

 

2.40

2.2/1.1

 

 

9.6/4.7-4.8

 

VERTICAL AIR DELIVERY UNIT HEATER MOTOR DATA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage and Motor Type

 

Motor Data

 

115/60/1

 

230/60/1

230/460/60/3

 

 

115/208 - 230/60/1

 

Totally Enclosed w/ Thermal Overload

Totally Enclosed

 

Explosion Proof

 

 

 

 

 

 

 

 

w/Thermal Overload

 

 

 

 

 

 

 

 

 

 

 

Model No.

Motor HP

 

 

 

 

 

 

Amps

 

BV-42

1/20

 

1.30

 

 

0.70

1.4/0.7

 

 

4.8/2.3-2.4

BV-59

1/20

 

1.30

 

 

0.70

1.4/0.7

 

 

4.8/2.3-2.4

BV-78

1/8

 

2.70

 

 

1.40

1.4/0.7

 

 

4.8/2.3-2.4

BV-95

1/8

 

2.70

 

 

1.40

1.4/0.7

 

 

4.8/2.3-2.4

BV-139

1/4

 

2.80

 

 

1.40

2.2/1.1

 

 

6.6/3.1-3.3

BV-161

1/4

 

2.80

 

 

1.40

2.2/1.1

 

 

6.6/3.1-3.3

BV-193

1/2

 

4.70

 

 

2.40

2.2/1.1

 

 

9.6/4.7-4.8

BV-212

1/2

 

4.70

 

 

2.40

2.2/1.1

 

 

9.6/4.7-4.8

BV-247

5/8

 

5.90

 

 

3.00

4.2/2.1

 

 

9.6/4.7-4.8

BV-279

5/8

 

5.90

 

 

3.00

4.2/2.1

 

 

9.6/4.7-4.8

BV-333

1

 

9.00

 

 

4.50

4.2/2.1

 

 

N/A

BV-385

1

 

N/A

 

 

 

N/A

4.2/2.1

 

 

N/A

BV-500

1-1/2

 

N/A

 

 

 

N/A

5.0/2.5

 

 

N/A

BV-610

1-1/2

 

N/A

 

 

 

N/A

5.0/2.5

 

 

N/A

 

 

 

 

 

Motor/Power Codes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor/Power

 

 

 

Description

 

 

 

 

 

 

Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01

115V, 60 HZ, 1PH

 

 

 

 

 

 

02

230V, 60HZ, 1PH

 

 

 

 

 

 

05

230V/460V, 60HZ, 3PH

 

 

 

 

 

 

06

115V/208-230V, 60HZ, 1PH, Explosion Proof

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27

Image 27
Contents 8144A001R4-2/07 BH and BV Unit HeatersTable of Contents Important Information Read Carefully Before Installation II. General Information III. InstallationUnit Heater Mounting Height Wiring Instructions115V / 60Hz / 1PH Wiring Schematic Hot Water System Piping Recommended Maximum Mounting HeightIV. Operation Prior to OperationInitial START-UP Casings MaintenanceInspect Regularly MotorsLarge Factories, Fabrication Shops VI. Application GuidelinesGeneral Guidelines Typical BH Unit Arrangement Sound Class RatingsSteam Performance Data Steam Performance Data -- High Motor SpeedSteam Performance Data -- Reduced Motor Speed Selection Procedure Steam Application Application ProcedureGiven Design Conditions Fata = Eata + Atra Steam Calculation FormulasHeater Air Temp Types 100 125 150 Steam Correction FactorsSteam Heating Capacity Conversion Factors Unit EnteringCorrection Factor Air Temperature Rise Conversion FactorsSteam Unit Heater Mounting Height Correction Factors Steam Pressure PsigProperties of Steam Gauge Temp Latent HeatBtu/lb Hot Water Performance Data -- Reduced Motor Speed Hot Water Performance Data -- High Motor Speed125,020 Btu/hr Final Air Selection Procedure HOT Water ApplicationWater Temperature Water Flow RateBtuAG = BtuS or BtuA x Glycol Correction Factor HOT Water Calculation FormulasHot Water Unit Heater Mounting Height Correction Factors HOT Water Correction FactorsHot Water Heating Capacity Conversion Factors Ethylene Glycol Correction FactorsControl Sequences VII. OPTIONS, Accessories and Control SequencesField Installed Options for Horizontal and Vertical Models Field Installed Options for Horizontal Models onlyDescription Field Installed Options for Vertical Models onlyVertical Air Outlet Accessory Dimensions Cone-JetLou Truncone No Deflector Anemo Vertical Air Outlet Accessory Maximum Height and Spread123VIII. Dimensional Data BH Dimensional DataModel BH Dimensions BV Dimensional Data Model BV DimensionsMale NPT Fan Ship Model Voltage and Motor Type Motor/Power CodesMotor/Power Description Code IX. Motor DataLimited Warranty