Desa PROPANE GAS LOG HEATER installation manual If Using Mantel

Page 11

INSTALLING

Continued

Minimum Non Combustible Material Clearances

If Using Mantel

You must have non combustible material(s) above the fireplace opening. Non combustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have non combustible material behind it. Non combustible material must extend at least 8 inches up. If combustible material is less than 12", you must install the fireplace hood accessory. Even if non combus- tible material is more than 12", you may need the hood accessory to deflect heat away from your mantel shelf. See chart below and Figures 6 and 7 for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Installing Damper Clamp Accessory for Vented Operation, page 13.

Non Combustible

Requirements for

Material Distance (A)

Safe Installation

 

 

12" or more

Non combustible material OK.

Between 8" and 12"

Install fireplace hood acessory (GA6050

 

or GA6052, see Accessories, page 31).

Less than 8"

Non combustible material must be

 

extended to at least 8". See Between 8"

 

and 12", above. If you cannot extend

 

material, you must operate heater with

 

flue damper open.

 

 

Mantel Clearances

If you meet minimum clearance between mantel shelf and top of fireplace opening, a hood is not required (see Figure 6).

 

10"

 

Mantel Shelf

Underside of

 

8"

 

 

 

 

 

 

 

 

 

 

 

 

 

Mantel Shelf

 

 

 

 

 

 

 

 

 

 

6"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 1/2"

 

 

 

 

 

 

All minimum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

distances are

Minimum Non-

 

 

(A)

 

 

 

 

 

 

in inches

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Combustible

 

 

 

 

 

 

 

 

Log Set

 

 

 

 

 

 

 

 

 

Material

 

 

 

 

 

 

 

 

 

 

 

12"

20"

 

241/2"

271/2"

30"

 

24"/30" Models

 

 

 

 

 

 

 

 

8"

14"

 

163/4"

181/2"

20"

 

18" Model

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top of Fireplace

Opening

Minimum Non-

Distances to

Combustible

Underside of

Material Height

Mantel

Figure 6 - Minimum Mantel Clearances Without Using Hood

If above minimum clearances are not met, you must have a hood. Follow minimum clearances shown in Figure 7 when using hood.

Continued 11

102318

Image 11
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information 001 Piezo Ignition System Local Codes Unpacking Product FeaturesSafety Device OperationUnconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space Determining AIR Flow for Heater LocationVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building High traffic areas Windy or drafty areas InstallingCheck GAS Type Minimum Wall and Ceiling Clearances see Figure Minimum Fireplace Clearance To Combustible MaterialsLOG Sizing Requirements Minimum Non Combustible Material Clearances If Using Mantel Floor Clearances Attaching Damper Clamp Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Installing Heater Base AssemblyAttaching Mounting Brackets to Heater Connecting to GAS SupplyExternal Regulator With Vent Pointing Down Checking GAS Connections Pressure Testing gas Supply Piping systemTest Pressures Equal To or Less Than 1/2 Psig Pressure Testing Heater Gas ConnectionsNotch Front Log #1R Grate Prongs Metal Grate Bar Installing LogsInstalling Rear Log #3 Installing Crossover Log #5 Operating Heater To Turn OFF GAS to Appliance Operating HeaterFront Burner Flame Pattern Inspecting BurnersPilot Flame Pattern Logs Cleaning and Maintenance Trouble ShootingTurn off heater and let cool before cleaning ODS/PILOT and BurnersTROUBLE- Shooting Cleaning and MainteRefer to Air for Com Statement at top Trouble ShootingService Hints Technical ServiceParts Not Under Warranty Replacement PartsParts Under Warranty Hood GA6052 AccessoriesValve GA5010 Hood GA6050Illustrated Parts Breakdown KEY Part Number Description QTY Parts List102318 102318 Keep this Warranty Warranty Information