Desa PROPANE GAS LOG HEATER Cleaning and Maintenance Trouble Shooting, ODS/PILOT and Burners

Page 25

CLEANING AND MAINTENANCE

TROUBLE-

SHOOTING

Note: All trouble- shooting items are listed in order of operation.

WARNING

WARNING ICON

G 001

Turn off heater and let cool before cleaning.

CAUTION

WARNING ICON

G 001

You must keep control areas, burners, and circulating air passage- ways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, etc.

ODS/PILOT AND BURNERS

• Use a vacuum cleaner or small, soft bristled brush to clean.

LOGS

If you remove logs for cleaning, refer to Installing Logs, page 19, to properly replace logs.

Replace log(s) if broken or chipped (dime-sized or larger).

WARNING

WARNING ICON

G 001

Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair heater.

CAUTION

WARNING ICON

G 001

Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit.

OBSERVED

POSSIBLE

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

When ignitor button

1.

Ignitor electrode not con-

1.

Reconnect ignitor cable

is pressed, there is no

 

nected to ignitor cable

 

 

spark at ODS/pilot

2.

Ignitor cable pinched or

2.

Free ignitor cable if

 

 

wet

 

pinched by any metal or

 

 

 

 

tubing. Keep ignitor

 

 

 

 

cable dry

 

3.

Piezo ignitor nut is loose

3.

Tighten nut holding

 

 

 

 

piezo ignitor to base

 

 

 

 

panel of log set. Nut is

 

 

 

 

located behind base

 

 

 

 

panel.

 

4.

Broken ignitor cable

4.

Replace ignitor cable

 

5.

Bad piezo ignitor

5.

Replace piezo ignitor

 

6.

Ignitor electrode broken

6.

Replace piezo ignitor

 

7.

Ignitor electrode posi-

7.

Replace piezo ignitor

 

 

tioned wrong

 

 

Continued 25

102318

Image 25
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information 001 Safety Device Local Codes Unpacking Product FeaturesOperation Piezo Ignition SystemProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Determining AIR Flow for Heater LocationVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallingHigh traffic areas Windy or drafty areas LOG Sizing Requirements Minimum Fireplace Clearance To Combustible MaterialsMinimum Wall and Ceiling Clearances see Figure Minimum Non Combustible Material Clearances If Using Mantel Floor Clearances Attaching Damper Clamp Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Installing Heater Base AssemblyAttaching Mounting Brackets to Heater Connecting to GAS SupplyExternal Regulator With Vent Pointing Down Checking GAS Connections Pressure Testing gas Supply Piping systemTest Pressures Equal To or Less Than 1/2 Psig Pressure Testing Heater Gas ConnectionsNotch Front Log #1R Grate Prongs Metal Grate Bar Installing LogsInstalling Rear Log #3 Installing Crossover Log #5 Operating Heater To Turn OFF GAS to Appliance Operating HeaterPilot Flame Pattern Inspecting BurnersFront Burner Flame Pattern Turn off heater and let cool before cleaning Cleaning and Maintenance Trouble ShootingODS/PILOT and Burners LogsTROUBLE- Shooting Cleaning and MainteRefer to Air for Com Statement at top Trouble ShootingService Hints Technical ServiceParts Under Warranty Replacement PartsParts Not Under Warranty Valve GA5010 AccessoriesHood GA6050 Hood GA6052Illustrated Parts Breakdown KEY Part Number Description QTY Parts List102318 102318 Keep this Warranty Warranty Information