Desa PROPANE GAS LOG HEATER installation manual Trouble Shooting, Statement at top

Page 28

TROUBLE-

SHOOTING

Continued

28

WARNING

WARNING ICON

G 001

If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED

POSSIBLE

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

Heater produces a

1.

Metal expanding while

1.

This is common with

clicking/ticking noise

 

heating or contracting

 

most heaters. If noise is

just after burners are lit

 

while cooling

 

excessive, contact

or shut off

 

 

 

qualified service person

 

 

 

 

 

Heater produces

1.

Heater burning vapors

1.

Open window to ventilate

unwanted odors

 

from paint, hair spray,

 

room. Stop using odor

 

 

glues, cleaners, chemi-

 

causing products while

 

 

cals, new carpet, etc.

 

heater is running

 

 

(See IMPORTANT

 

 

 

 

statement above)

 

 

 

2.

Low fuel supply

2.

Refill supply tank

 

3.

Gas leak. See Warning

3.

Locate and correct all leaks

 

 

statement at top of

 

(see Checking Gas Con-

 

 

page

 

nections, page 17)

 

 

 

 

 

Heater shuts off in use

1.

Not enough fresh air is

1.

Open window and/or door

(ODS operates)

 

available

 

for ventilation

 

2.

Low line pressure

2.

Contact local propane gas

 

 

 

 

company

 

3.

ODS/pilot is partially

3.

Clean ODS/pilot (see

 

 

clogged

 

Cleaning and Mainte-

 

 

 

 

nance, page 25)

 

 

 

 

 

Gas odor even when

1.

Gas leak. See Warning

1.

Locate and correct all leaks

control knob is in OFF

 

statement at top of

 

(see Checking Gas Con-

position

 

page

 

nections, page 17)

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

Gas odor during

1.

Foreign matter between

1.

Take apart gas tubing and

combustion

 

control valve and burner

 

remove foreign matter

 

2.

Gas leak. See Warning

2.

Locate and correct all leaks

 

 

statement at top of

 

(see Checking Gas Con-

 

 

page

 

nections, page 17)

102318

Image 28
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information 001 Local Codes Unpacking Product Features Safety DeviceOperation Piezo Ignition SystemAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Unconfined SpaceDetermining AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallingHigh traffic areas Windy or drafty areas LOG Sizing Requirements Minimum Fireplace Clearance To Combustible MaterialsMinimum Wall and Ceiling Clearances see Figure Minimum Non Combustible Material Clearances If Using Mantel Floor Clearances Installing Damper Clamp Accessory for Vented Operation Attaching Damper ClampInstalling Heater Base Assembly Installation Items NeededConnecting to GAS Supply Attaching Mounting Brackets to HeaterExternal Regulator With Vent Pointing Down Pressure Testing gas Supply Piping system Checking GAS ConnectionsPressure Testing Heater Gas Connections Test Pressures Equal To or Less Than 1/2 PsigInstalling Logs Notch Front Log #1R Grate Prongs Metal Grate BarInstalling Rear Log #3 Installing Crossover Log #5 Operating Heater Operating Heater To Turn OFF GAS to AppliancePilot Flame Pattern Inspecting BurnersFront Burner Flame Pattern Cleaning and Maintenance Trouble Shooting Turn off heater and let cool before cleaningODS/PILOT and Burners LogsCleaning and Mainte TROUBLE- ShootingRefer to Air for Com Trouble Shooting Statement at topTechnical Service Service HintsParts Under Warranty Replacement PartsParts Not Under Warranty Accessories Valve GA5010Hood GA6050 Hood GA6052Illustrated Parts Breakdown Parts List KEY Part Number Description QTY102318 102318 Warranty Information Keep this Warranty