Bradford-White Corp D4504S*F(BN, D4403S*F(BN, SX) Abnormal Operation cont’d Flame Sensing Fault

Page 12

Sequence of Operation

Abnormal Operation (cont’d)

5.Flame Sensing Fault:

A)Flame Lost During Run: The gas control turns off pilot and main valves. The gas control increments the recycle count, if the recycle count has not reached its limit (4), another trial for ignition begins. If the recycle count has been reached, the gas control LED flashes 6 times then 3 times with a 3 second pause. The gas control waits 5 minutes before repeating the ignition sequence.

B)Flame Sensed Out of Sequence: The gas control only looks for pilot flame when the damper is in the open position. If flame is present when the pilot valve is not open, the gas control proceeds to wait for flame loss and flashes 5 times with 3 second pause. This continues until flame is lost. Once the flame signal is lost, the control flashes 6 times then 4 times with a 3 second pause. The control waits 5 minutes before repeating the ignition sequence.

Page 12

12

Image 12
Contents Service Manual Table of Contents Page Page Bradford White Defender Safety System How the Safety System WorksIntroduction IntroductionHow to Use this Manual How to Use this ManualSpecifications Wiring Diagram Power Up Sequence Damper Powered OpenSequence of Operation Normal Heating SequenceNormal Heating Sequence cont’d Abnormal Operation cont’d Temperature Sensor Fault Damper Safety Circuit FaultTrial for Ignition Fault Abnormal Operation cont’d Flame Sensing Fault Troubleshooting Probable Cause Service ProcedureLED Status Control Status Probable Cause Service Procedure Burner Maintenance Burner Cleaning ProcedureBurner Inspection Right side inner door Main burner Orifice Pilot Maintenance Burner Cleaning Procedure cont’dPilot Inspection, Testing and Replacement Pilot Inspection, Testing and Replacement cont’d Damper Replacement Damper Removal & InstallationDamper Removal & Installation cont’d Thermal Well Testing Thermal Well TestingDetermine Tank Temperature Thermal Well Testing cont’dDetermine Water Temperature Inside Tank Component Disassembly Sensor Resistance at Various TemperaturesGas Control & Thermal Well Removal From Water Heater Gas Control Removal Gas Control & Thermal Well Removal From Water Heater cont’dGas Control Removal From Thermal Well Gas Control Assembly Gas Control Assembly to the Thermal WellGas Control Removal From Thermal Well cont’d Gas Control Assembly to the Thermal Well cont’d Flammable Vapor Sensor Testing Flammable Vapor Sensor TestingVAC Circuit Trace Dip Tube Inspection and Replacement Dip Tube InspectionAnode Inspection and Replacement Anode InspectionRemove the Damper to Gain Access to the Flue Baffle Damper RemovalRemove the Damper to Gain Access to the Flue Baffle cont’d Inner Door Removal Procedure Inner Door RemovalInner Door Gasket Replacement Inner Door Removal Procedure cont’dInner Door Gasket Replacement Procedure Inner Door Installation Inner Door Installation with GasketArrestor Cleaning ScreenLok Flame Arrestor Cleaning ProcedureDamper Relay Installation Damper Relay Installation Damper Relay Installation cont’dConnect the other ends of the relay harness, as shown Common Terms Common TermsParts List Part Name and DescriptionParts@bradfordwhite.com Techserv@bradfordwhite.com

SX), D4504S*F(BN, D4403S*F(BN specifications

Bradford-White Corp has long been a pioneering name in the water heating industry, and their D4403S*F(BN, D4504S*F(BN, and SX models represent the company’s commitment to delivering high-quality, efficient solutions for residential and commercial applications. These water heaters are designed with various user needs in mind, ensuring that homeowners and businesses can enjoy a reliable hot water supply whenever needed.

One of the core features of these models is their advanced water heating technology. Utilizing power venting systems, these units ensure efficient heat transfer while minimizing heat loss. This technology promotes energy efficiency and helps users save on their energy bills. The power vent system also allows for flexible installation options, accommodating different types of venting configurations, which is especially useful in homes with unique designs or limited space.

The Bradford-White D4403S*F(BN and D4504S*F(BN models are equipped with their state-of-the-art Hydrojet Total Performance System. This feature not only enhances the heater's overall performance but also reduces sediment buildup within the tank, which can significantly extend the unit's lifespan and maintain efficiency over time. Moreover, the patented Vitraglas® lining protects the inner tank from corrosion, further prolonging the life of the appliance.

Safety is a paramount consideration in Bradford-White's design philosophy. Each model includes a robust Flammable Vapor Ignition Resistance (FVIR) system, which helps prevent the ignition of flammable vapors that may be present in the vicinity of the water heater. This feature meets stringent safety standards and provides peace of mind to users.

In terms of energy specifications, both the D4403S*F(BN and D4504S*F(BN models are designed to meet or exceed efficiency standards, contributing to lower energy consumption and environmental impact. The SX model is particularly notable for its user-friendly digital display and controls, allowing for easy temperature adjustments and efficient operation monitoring.

In conclusion, Bradford-White Corp's D4403S*F(BN, D4504S*F(BN, and SX models are a testament to the company’s dedication to quality, safety, and efficiency in water heating technology. With their innovative features, user-friendly design, and long-lasting durability, these water heaters are well-suited to meet the ever-evolving demands of modern households and commercial settings alike. As homeowners and businesses continue seeking reliable hot water solutions, Bradford-White stands out as a trusted choice in the industry.