Parts List

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

3

 

 

 

 

 

7

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

9

 

 

 

4

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

11

 

 

 

17

 

 

 

 

 

 

 

 

 

18

 

 

 

 

 

 

 

 

 

19

 

 

 

 

14

12

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21

16

 

15

 

 

 

 

 

 

 

 

 

 

 

 

 

23

22

24

 

 

 

13

 

 

 

 

25

 

 

 

 

 

 

 

27

26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15A

 

 

 

 

 

 

 

 

PART NAME AND DESCRIPTION

 

 

 

1.

Draft Hood

 

 

 

15.

Inner Door (Right)

 

 

 

2.

Damper

 

 

 

15A. Resettable Thermal Switch

 

 

 

3.

Jacket Head Pan

 

 

 

16.

Inner Door (Left)

 

 

 

4.

Jacket

 

 

 

17.

Damper Wire Harness

 

 

 

5.

Heat Trap—Cold Water Inlet

 

18.

Thermal Well

 

 

 

6.

Magnesium Anode–Hot Water Outlet

 

19.

Gas Control Valve

 

 

 

7.

Heat Trap—Cold Water

 

 

20.

Wire Harness (FVS / RTS)

 

 

 

8.

Flue Baffle Assembly

 

 

 

21.

FVS Sensor Clip

 

 

 

9.

Dip Tube–Cold Water Inlet

 

 

22.

Flammable Vapor Sensor (FVS)

 

 

 

10. Temperature and Pressure Relief Valve

 

23.

Outer Door

 

 

 

11. Glass Lined Tank

 

 

 

24.

Steel Burner

 

 

 

12. Combustion Chamber Assembly

 

25.

Orifice

 

 

 

13. Jacket Base Pan

 

 

 

26.

Pilot Assembly

 

 

 

14. Drain Valve

 

 

 

27.

Feedline

 

 

Page 39

39

Image 39
Contents Service Manual Table of Contents Page Page Introduction Bradford White Defender Safety SystemHow the Safety System Works IntroductionHow to Use this Manual How to Use this ManualSpecifications Wiring Diagram Normal Heating Sequence Power Up SequenceDamper Powered Open Sequence of OperationNormal Heating Sequence cont’d Abnormal Operation cont’d Temperature Sensor Fault Damper Safety Circuit FaultTrial for Ignition Fault Abnormal Operation cont’d Flame Sensing Fault Probable Cause Service Procedure TroubleshootingLED Status Control Status Probable Cause Service Procedure Burner Maintenance Burner Cleaning ProcedureBurner Inspection Right side inner door Main burner Orifice Pilot Maintenance Burner Cleaning Procedure cont’dPilot Inspection, Testing and Replacement Pilot Inspection, Testing and Replacement cont’d Damper Removal & Installation Damper ReplacementDamper Removal & Installation cont’d Thermal Well Testing Thermal Well TestingDetermine Tank Temperature Thermal Well Testing cont’dDetermine Water Temperature Inside Tank Component Disassembly Sensor Resistance at Various TemperaturesGas Control & Thermal Well Removal From Water Heater Gas Control Removal Gas Control & Thermal Well Removal From Water Heater cont’dGas Control Removal From Thermal Well Gas Control Assembly Gas Control Assembly to the Thermal WellGas Control Removal From Thermal Well cont’d Gas Control Assembly to the Thermal Well cont’d Flammable Vapor Sensor Testing Flammable Vapor Sensor TestingVAC Circuit Trace Dip Tube Inspection Dip Tube Inspection and ReplacementAnode Inspection Anode Inspection and ReplacementDamper Removal Remove the Damper to Gain Access to the Flue BaffleRemove the Damper to Gain Access to the Flue Baffle cont’d Inner Door Removal Inner Door Removal ProcedureInner Door Gasket Replacement Inner Door Removal Procedure cont’dInner Door Gasket Replacement Procedure Inner Door Installation with Gasket Inner Door InstallationArrestor Cleaning ScreenLok Flame Arrestor Cleaning ProcedureDamper Relay Installation Damper Relay Installation cont’d Damper Relay InstallationConnect the other ends of the relay harness, as shown Common Terms Common TermsPart Name and Description Parts ListParts@bradfordwhite.com Techserv@bradfordwhite.com

SX), D4504S*F(BN, D4403S*F(BN specifications

Bradford-White Corp has long been a pioneering name in the water heating industry, and their D4403S*F(BN, D4504S*F(BN, and SX models represent the company’s commitment to delivering high-quality, efficient solutions for residential and commercial applications. These water heaters are designed with various user needs in mind, ensuring that homeowners and businesses can enjoy a reliable hot water supply whenever needed.

One of the core features of these models is their advanced water heating technology. Utilizing power venting systems, these units ensure efficient heat transfer while minimizing heat loss. This technology promotes energy efficiency and helps users save on their energy bills. The power vent system also allows for flexible installation options, accommodating different types of venting configurations, which is especially useful in homes with unique designs or limited space.

The Bradford-White D4403S*F(BN and D4504S*F(BN models are equipped with their state-of-the-art Hydrojet Total Performance System. This feature not only enhances the heater's overall performance but also reduces sediment buildup within the tank, which can significantly extend the unit's lifespan and maintain efficiency over time. Moreover, the patented Vitraglas® lining protects the inner tank from corrosion, further prolonging the life of the appliance.

Safety is a paramount consideration in Bradford-White's design philosophy. Each model includes a robust Flammable Vapor Ignition Resistance (FVIR) system, which helps prevent the ignition of flammable vapors that may be present in the vicinity of the water heater. This feature meets stringent safety standards and provides peace of mind to users.

In terms of energy specifications, both the D4403S*F(BN and D4504S*F(BN models are designed to meet or exceed efficiency standards, contributing to lower energy consumption and environmental impact. The SX model is particularly notable for its user-friendly digital display and controls, allowing for easy temperature adjustments and efficient operation monitoring.

In conclusion, Bradford-White Corp's D4403S*F(BN, D4504S*F(BN, and SX models are a testament to the company’s dedication to quality, safety, and efficiency in water heating technology. With their innovative features, user-friendly design, and long-lasting durability, these water heaters are well-suited to meet the ever-evolving demands of modern households and commercial settings alike. As homeowners and businesses continue seeking reliable hot water solutions, Bradford-White stands out as a trusted choice in the industry.