WARNING

Water heaters are heat producing appliances. To avoid damage or injury, do not store materials against the water heater or any of its components. Use proper care to avoid un- necessary contact, especially by children, with the water heater and its components. Un- der no circumstances must flammable materials, such as gasoline or paint thinner be used or stored in the vicinity of this water heater or in any location in which the fumes could reach the water heater.

Hydrogen gas can be produced in an operating water heater that has not had water drawn from the tank for a long period of time (generally two weeks or more). Hydrogen gas is extremely flammable. To prevent the possibility of injury under these conditions, we rec- ommend a hot water faucet to be open for several minutes at the kitchen sink before you use any electrical appliance which is connected to the hot water system. If hydrogen is present, there will be an unusual sound such as air escaping through the pipes as hot wa- ter begins to flow. Do not smoke or have open flame near the faucet at the time it is open.

DO NOT ATTEMPT TO LIGHT ANY GAS APPLIANCE IF YOU ARE NOT CERTAIN OF THE FOL- LOWING:

Liquefied petroleum gases/propane gas and natural gas have an odorant added by the gas supplier that aids in the detection of the gas. Most people recognize this odor as a “sulfur” or “rotten egg” smell. Other conditions, such as “odorant fade” can cause the odorant to diminish in intensity, or ”fade,” and not be as readily detectable. If you have a diminished sense of smell, or are in any way unsure of the presence of gas, immediately contact your gas supplier from a neighbor's telephone. Gas detectors are available. Contact your gas supplier, or plumbing professional for more information.

FAILURE TO INSTALL AND MAINTAIN A NEW, LISTED 3/4” X 3/4” TEMPERATURE AND PRESSURE RELIEF VALVE WILL RELEASE THE MANUFACTURER FROM ANY CLAIM THAT MIGHT RESULT FROM EXCESSIVE TEMPERATURE AND PRESSURES.

Page 4

4

Image 4
Contents Service Manual Table of Contents Page Page Bradford White Defender Safety System How the Safety System WorksIntroduction IntroductionHow to Use this Manual How to Use this ManualSpecifications Wiring Diagram Power Up Sequence Damper Powered OpenSequence of Operation Normal Heating SequenceNormal Heating Sequence cont’d Damper Safety Circuit Fault Abnormal Operation cont’d Temperature Sensor FaultTrial for Ignition Fault Abnormal Operation cont’d Flame Sensing Fault Troubleshooting Probable Cause Service ProcedureLED Status Control Status Probable Cause Service Procedure Burner Cleaning Procedure Burner MaintenanceBurner Inspection Right side inner door Main burner Orifice Burner Cleaning Procedure cont’d Pilot MaintenancePilot Inspection, Testing and Replacement Pilot Inspection, Testing and Replacement cont’d Damper Replacement Damper Removal & InstallationDamper Removal & Installation cont’d Thermal Well Testing Thermal Well TestingThermal Well Testing cont’d Determine Tank TemperatureDetermine Water Temperature Inside Tank Sensor Resistance at Various Temperatures Component DisassemblyGas Control & Thermal Well Removal From Water Heater Gas Control & Thermal Well Removal From Water Heater cont’d Gas Control RemovalGas Control Removal From Thermal Well Gas Control Assembly to the Thermal Well Gas Control AssemblyGas Control Removal From Thermal Well cont’d Gas Control Assembly to the Thermal Well cont’d Flammable Vapor Sensor Testing Flammable Vapor Sensor TestingVAC Circuit Trace Dip Tube Inspection and Replacement Dip Tube InspectionAnode Inspection and Replacement Anode InspectionRemove the Damper to Gain Access to the Flue Baffle Damper RemovalRemove the Damper to Gain Access to the Flue Baffle cont’d Inner Door Removal Procedure Inner Door RemovalInner Door Removal Procedure cont’d Inner Door Gasket ReplacementInner Door Gasket Replacement Procedure Inner Door Installation Inner Door Installation with GasketScreenLok Flame Arrestor Cleaning Procedure Arrestor CleaningDamper Relay Installation Damper Relay Installation Damper Relay Installation cont’dConnect the other ends of the relay harness, as shown Common Terms Common TermsParts List Part Name and DescriptionParts@bradfordwhite.com Techserv@bradfordwhite.com

SX), D4504S*F(BN, D4403S*F(BN specifications

Bradford-White Corp has long been a pioneering name in the water heating industry, and their D4403S*F(BN, D4504S*F(BN, and SX models represent the company’s commitment to delivering high-quality, efficient solutions for residential and commercial applications. These water heaters are designed with various user needs in mind, ensuring that homeowners and businesses can enjoy a reliable hot water supply whenever needed.

One of the core features of these models is their advanced water heating technology. Utilizing power venting systems, these units ensure efficient heat transfer while minimizing heat loss. This technology promotes energy efficiency and helps users save on their energy bills. The power vent system also allows for flexible installation options, accommodating different types of venting configurations, which is especially useful in homes with unique designs or limited space.

The Bradford-White D4403S*F(BN and D4504S*F(BN models are equipped with their state-of-the-art Hydrojet Total Performance System. This feature not only enhances the heater's overall performance but also reduces sediment buildup within the tank, which can significantly extend the unit's lifespan and maintain efficiency over time. Moreover, the patented Vitraglas® lining protects the inner tank from corrosion, further prolonging the life of the appliance.

Safety is a paramount consideration in Bradford-White's design philosophy. Each model includes a robust Flammable Vapor Ignition Resistance (FVIR) system, which helps prevent the ignition of flammable vapors that may be present in the vicinity of the water heater. This feature meets stringent safety standards and provides peace of mind to users.

In terms of energy specifications, both the D4403S*F(BN and D4504S*F(BN models are designed to meet or exceed efficiency standards, contributing to lower energy consumption and environmental impact. The SX model is particularly notable for its user-friendly digital display and controls, allowing for easy temperature adjustments and efficient operation monitoring.

In conclusion, Bradford-White Corp's D4403S*F(BN, D4504S*F(BN, and SX models are a testament to the company’s dedication to quality, safety, and efficiency in water heating technology. With their innovative features, user-friendly design, and long-lasting durability, these water heaters are well-suited to meet the ever-evolving demands of modern households and commercial settings alike. As homeowners and businesses continue seeking reliable hot water solutions, Bradford-White stands out as a trusted choice in the industry.