| Specifications | |
|
|
|
|
|
|
|
|
| Power Supply | Dedicated 120VAC, 60 Hz, 15A |
|
|
|
|
|
| Gas Supply Pipe | Minimum 1/2” NPT (Schedule 40 black iron pipe |
|
| recommended) |
| |
|
|
| |
|
|
|
|
| Approved Gas Type | Natural or Propane; unit must match gas type supplied |
|
|
|
|
|
| Gas Pressure | 5” w.c. minimum for Natural Gas; 11” w.c. for Propane; |
|
| 14” w.c. maximum for Natural Gas / Propane |
| |
|
|
| |
|
|
|
|
| Approved Vent Materials | Single or Double Wall Metal Vent Pipe |
|
|
|
|
|
| Minimum Clearance for | 18” from top; 24” from front; 4” from sides and rear |
|
| Servicing |
| |
|
|
| |
|
|
|
|
| Water Supply Pressure | 150 psi maximum allowable working pressure; check local |
|
| codes for supply pressure |
| |
|
|
| |
|
|
|
|
| ECO Limit | 188°F (87°C) |
|
|
|
|
|
| Temperature Setpoint Range | 60°F (16°C) to 160°F (71°C); approximate temperatures |
|
|
|
|
|
Page 7
7