Bradford-White Corp EFR160T120, EFR-1-60T1206EN warranty Typical Horizontal Direct Vent System

Page 24

2.Use the proper PVC cement to secure the exhaust vent and air intake terminals provided with the water heater to the plastic pipes. The distance between the back edge of the exhaust vent terminal and the exterior wall (see Figure 13) must be 6 inches (12.7 cm) more for the exhaust vent terminal than the air intake terminal. Use the proper cement or sealant and assembly procedures to secure the vent connector joints between the terminal and the blower outlet.

Provide support brackets for every 3 feet (.9 m) of horizontal vent beyond the intake terminal.

Figure 13. Typical Horizontal Direct Vent System

Vertical Installation:

Vertical venting system must be supported every 5 feet (1.5 m) of vertical run and every 3 feet (.9 m) of horizontal run of vent pipe length.

CAUTION

Failure to properly support the vent piping with hangers and clamps may result in damage to the water heater or venting system.

Stress levels in the pipe and fittings can be significantly increased by improper installation. If rigid pipe clamps are used to hold the pipe in place, or if the pipe cannot move freely through a wall penetration, the pipe may be directly stressed, or high thermal stresses may be formed when the pipe heats up and expands. Install accordingly to minimize such stresses.

Follow the following procedure to vent through the roof:

1.Cut the necessary holes through the roof and ceiling.

2.Install the exhaust vent and air intake plastic pipes as shown in Figure 14. Make sure that the installation meets the local codes and/or The National Fuel Gas Code ANSI Z223.1 (Latest Edition) or CGA/CAN B149 Installation Code (Latest Edition).

24

Image 24
Contents With Troubleshooting Guide What to do if YOU Smell GASTable of Contents Page Do not Operate the Appliance Until the Leakage is Corrected Section II Specifications Dimensions InchesFeatures Section III General InformationTemperature and Pressure Relief Valve Condensate Elbow With Trap Section IV Installation Instructions Do not Operate the Appliance Until the Leakage is CorrectedUnpacking Minimum Clearance To Combustible Material Location Remove CrateAIR Requirements Typical Installation Illustration Mechanical Exhausting of Room AIRUnconfined Space Confined SpaceTypical Front Inlet Connection Typical Two Water Heater Connection Section V Water Connections Instructions for ConnectionsScalding Approximate TIME/TEMPERATURE Relationships in Scalds Alternate Space Heating Water ConnectionsSection VI Venting Page Direct Vent Installation VentingCanadian US Installations2 Installations1 Direct Vent Terminal Clearances Page Typical Horizontal Direct Vent System Typical Vertical Direct Vent System Installation Power Vent Installation Cm PVC, CpvcPage Typical Horizontal Power Vent System Typical Vertical Power Vent System Installation Power Vent Maximum Vent Length Multiple INTAKE/EXHAUST Terminal Separation Distances Vertical Installation Concentric Vent Terminal Installation ProcedureRain Cap to Small Vent Pipe Assembly Horizontal Installation Vent Pipe PreparationSection VII GAS Connections Initial PreparationSelection of Materials GAS Meter Size Natural Gases only GAS Pressure RegulationWiring Diagram and Schematic Section Viii Electrical ConnectionsSection IX Operating Instructions General InstructionsTo Fill the Water Heater Sequence of OperationFor Your Safety Read Before Lighting Lighting and SHUT-DOWN InstructionsTemperature Adjustment Status Indicator Or Service NeededReads Idle or Heating Read OperationalPress SET Button for setting to take effect immediately Setpoint flashes for 10 secondsTo Decrease Setpoint Temperature Press select Changes to CSymbol F/C Stops Flashing Press SetSetpoint shown in F Press select StepSection X Maintenance GeneralBurner Flame Check Maintenance Schedule Sight Glass LocationFlushing Water Heater Draining Water HeaterFilling Water Heater Sediment and Lime Scale RemovalAnode Inspection and Replacement Drain Valve and Tank Access PanelRelief Valve Vent and AIR Intake System Combustion System InspectionSection XI Diagnostic and Troubleshooting Guide Max Setpoint Next to Temperature Setpoint value Water Heater Display Max Setpoint value Water Heater DisplayHeating No current error codes Max Setpoint Flashes Max Setpoint continues to flash Max Setpoint stops flashingDisplay of Water Temperature To Display Flame Sense Current of the Pilot Flame SensorTo Display and Change Temperature Setpoint Setpoint FlashesSetpoint Stops Flashing Changes to C F/C Flashes FlashesSymbol Stops Flashing How to reset the control from Lockout Conditions Resetting Error Codes in Soft Lockout ConditionResetting Error Codes in Hard Lockout Condition Press for 3 seconds to reset control in service modeError Code History To view previous error codesNo Current Error Code Error Code Index No Error Code Shown for Code IndexStored Error Code For Code Index #9 ExitingSELECTServiceSETMode Page Procedure for Checking Thermostat Sensors Section XII Parts List EF Series Water HeaterCombustion Surround Assembly Combustion Assembly pictured previous Ignition Control Assembly
Related manuals
Manual 76 pages 32.48 Kb

EFR-1-60T1206EN, EFR160T120 specifications

Bradford-White Corporation is a leading manufacturer of residential and commercial water heating solutions, and one of its standout products is the EFR160T120, also known as the EFR-1-60T1206EN. This innovative electric water heater is designed for those seeking reliable performance, energy efficiency, and long-lasting durability.

The EFR160T120 has an impressive capacity of 60 gallons, making it suitable for households with higher hot water demands. This model features a compact design, allowing it to fit into various installation spaces, such as utility rooms or small basements, without compromising on performance. Its vertical configuration and dimensions ensure that it occupies minimal floor space while delivering optimal hot water supply.

One of the most notable features of the EFR160T120 is its high-efficiency electric heating elements. This water heater is equipped with multiple heating elements that provide quick recovery rates, ensuring that hot water is readily available when it is needed most. The intelligent design employs a top-mounted thermostat that allows for accurate temperature control, promoting consistent hot water delivery for showers, baths, and household chores.

In terms of technology, the EFR160T120 incorporates advanced insulation technology that minimizes heat loss, enhancing energy efficiency. This feature not only contributes to reduced energy bills but also lowers carbon emissions, aligning with modern eco-conscious standards. The unit features an integrated temperature and pressure relief valve, which enhances safety by preventing excessive pressure build-up and protecting the tank from potential damage.

Durability is another strong suit of the EFR160T120, as it is constructed from high-quality materials. The tank is coated with a glass lining that protects against corrosion, extending the overall life of the unit. The heater is also backed by Bradford-White's reputation for quality craftsmanship, providing peace of mind for consumers.

Furthermore, the EFR160T120 is designed with user convenience in mind. Maintenance is straightforward, and replacement parts are readily available, which facilitates easy repairs and servicing. Overall, the Bradford-White EFR160T120 water heater stands out as a reliable and efficient choice for homes that require ample hot water supply without sacrificing space or energy efficiency.