Bradford-White Corp EFR-1-60T1206EN, EFR160T120 warranty Canadian US Installations2 Installations1

Page 21

Figure 12a. Vent Terminal Clearances (Other than Direct Vent or “Power Vented” Installations)

 

 

Canadian

US

 

 

Canadian

US Installations2

 

 

Installations1

Installations2

 

 

Installations1

 

 

 

 

 

 

 

3 feet (.9 m) within a

 

A=

Clearance above

12 inches

12 inches

H=

Clearance to each side

*b

 

grade, veranda, porch,

(30.5 cm)

(30.5 cm)

 

of center line extended

height 15 feet (4.6 m)

 

 

deck or balcony

 

 

 

above meter/regulator

above the

 

 

 

 

 

 

assembly

meter/regulator

 

 

 

 

 

 

 

assembly

 

B=

Clearance to widow or

36 inches

4 feet (1.2 m)

I=

Clearance to service

36 inches

*b

 

door that may be

(91.4 cm)

below or to the

 

regulator vent outlet or

(91.4 cm)

 

 

opened

 

side of opening;

 

oil tank vent

 

 

 

 

 

12 inches

 

 

 

 

 

 

 

(30.5 cm)

 

 

 

 

 

 

 

above opening

 

 

36 inches

 

C=

Clearance to

*b

*b

J=

Clearance to non-

4 feet (1.2 m)

 

permanently closed

 

 

 

mechanical air supply

(91.4 cm)

below or to side

 

window

 

 

 

inlet to building or the

 

of opening; 12

 

 

 

 

 

combustion air inlet to

 

inches (30.5 cm)

 

 

 

 

 

any other appliance

6 feet

above opening.

D=

Vertical clearance to

*b

*b

K=

Clearance to a

3 feet (.9 m)

 

ventilated soffit

 

 

 

mechanical air supply

(1.8 m)

above if within

 

located above the

 

 

 

inlet

 

10 feet (3 m)

 

terminal within a

 

 

 

 

 

horizontally

 

horizontal distance of

 

 

 

 

 

 

 

2 feet (.61 m) from the

 

 

 

 

 

 

 

center line of the

 

 

 

 

 

 

 

terminal

 

 

 

 

7 feet

 

E=

Clearance to

*b

*b

L=

Clearance above paved

7 feet

 

unventilated soffit

 

 

 

sidewalk or paved

(2.1 m)

(2.1 m)

 

 

 

 

 

driveway located on

 

 

 

 

 

 

 

public property

12 inches (30.5 cm)

 

F=

Clearance to outside

*b

*b

M=

Clearance under a

*b

 

corner

 

 

 

veranda, porch, deck, or

 

 

 

 

 

 

 

balcony

 

 

G=

Clearance to inside

36 inches

36 inches

 

 

 

 

 

corner

(91.4 cm)*a

(91.4 cm)*a

 

 

 

 

1In accordance with the current CAN/CGA-B149 Installation Codes.

2In accordance with the current ANSI Z223.1-(Latest Edition)/NFPA 54 National Fuel Gas Code.

A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single-family dwellings and serves both dwellings.

‡ Permitted only if a veranda, porch, deck or balcony is fully open on a minimum of two sides beneath the floor. *a) A minimum clearance value determined by testing in accordance with section 2.20.

*b) “Clearance in accordance with local installation codes and the requirements of the gas supplier”.

21

Image 21
Contents What to do if YOU Smell GAS With Troubleshooting GuideTable of Contents Page Do not Operate the Appliance Until the Leakage is Corrected Dimensions Inches Section II SpecificationsSection III General Information FeaturesTemperature and Pressure Relief Valve Condensate Elbow With Trap Do not Operate the Appliance Until the Leakage is Corrected Section IV Installation InstructionsUnpacking Minimum Clearance To Combustible Material Location Remove CrateAIR Requirements Mechanical Exhausting of Room AIR Typical Installation IllustrationUnconfined Space Confined SpaceTypical Front Inlet Connection Typical Two Water Heater Connection Section V Water Connections Instructions for ConnectionsScalding Alternate Space Heating Water Connections Approximate TIME/TEMPERATURE Relationships in ScaldsSection VI Venting Page Venting Direct Vent InstallationCanadian US Installations2 Installations1 Direct Vent Terminal Clearances Page Typical Horizontal Direct Vent System Typical Vertical Direct Vent System Installation Cm PVC, Cpvc Power Vent InstallationPage Typical Horizontal Power Vent System Typical Vertical Power Vent System Installation Power Vent Maximum Vent Length Multiple INTAKE/EXHAUST Terminal Separation Distances Concentric Vent Terminal Installation Procedure Vertical InstallationRain Cap to Small Vent Pipe Assembly Vent Pipe Preparation Horizontal InstallationSection VII GAS Connections Initial PreparationSelection of Materials GAS Pressure Regulation GAS Meter Size Natural Gases onlySection Viii Electrical Connections Wiring Diagram and SchematicGeneral Instructions Section IX Operating InstructionsTo Fill the Water Heater Sequence of OperationLighting and SHUT-DOWN Instructions For Your Safety Read Before LightingTemperature Adjustment Or Service Needed Status IndicatorReads Idle or Heating Read OperationalSetpoint flashes for 10 seconds Press SET Button for setting to take effect immediatelyTo Decrease Setpoint Temperature Changes to C Press selectPress Set Symbol F/C Stops FlashingSetpoint shown in F Press select StepSection X Maintenance GeneralBurner Flame Check Sight Glass Location Maintenance ScheduleDraining Water Heater Flushing Water HeaterFilling Water Heater Sediment and Lime Scale RemovalAnode Inspection and Replacement Drain Valve and Tank Access PanelRelief Valve Combustion System Inspection Vent and AIR Intake SystemSection XI Diagnostic and Troubleshooting Guide Max Setpoint Next to Temperature Setpoint value Max Setpoint value Water Heater Display Water Heater DisplayHeating No current error codes Max Setpoint Flashes Max Setpoint stops flashing Max Setpoint continues to flashTo Display Flame Sense Current of the Pilot Flame Sensor Display of Water TemperatureSetpoint Flashes To Display and Change Temperature SetpointSetpoint Stops Flashing Flashes Changes to C F/C FlashesSymbol Stops Flashing Resetting Error Codes in Soft Lockout Condition How to reset the control from Lockout ConditionsResetting Error Codes in Hard Lockout Condition Press for 3 seconds to reset control in service modeError Code History To view previous error codesNo Current Error Code No Error Code Shown for Code Index Error Code IndexStored Error Code For Code Index #9 ExitingSELECTServiceSETMode Page Procedure for Checking Thermostat Sensors EF Series Water Heater Section XII Parts ListCombustion Surround Assembly Ignition Control Assembly Combustion Assembly pictured previous
Related manuals
Manual 76 pages 32.48 Kb

EFR-1-60T1206EN, EFR160T120 specifications

Bradford-White Corporation is a leading manufacturer of residential and commercial water heating solutions, and one of its standout products is the EFR160T120, also known as the EFR-1-60T1206EN. This innovative electric water heater is designed for those seeking reliable performance, energy efficiency, and long-lasting durability.

The EFR160T120 has an impressive capacity of 60 gallons, making it suitable for households with higher hot water demands. This model features a compact design, allowing it to fit into various installation spaces, such as utility rooms or small basements, without compromising on performance. Its vertical configuration and dimensions ensure that it occupies minimal floor space while delivering optimal hot water supply.

One of the most notable features of the EFR160T120 is its high-efficiency electric heating elements. This water heater is equipped with multiple heating elements that provide quick recovery rates, ensuring that hot water is readily available when it is needed most. The intelligent design employs a top-mounted thermostat that allows for accurate temperature control, promoting consistent hot water delivery for showers, baths, and household chores.

In terms of technology, the EFR160T120 incorporates advanced insulation technology that minimizes heat loss, enhancing energy efficiency. This feature not only contributes to reduced energy bills but also lowers carbon emissions, aligning with modern eco-conscious standards. The unit features an integrated temperature and pressure relief valve, which enhances safety by preventing excessive pressure build-up and protecting the tank from potential damage.

Durability is another strong suit of the EFR160T120, as it is constructed from high-quality materials. The tank is coated with a glass lining that protects against corrosion, extending the overall life of the unit. The heater is also backed by Bradford-White's reputation for quality craftsmanship, providing peace of mind for consumers.

Furthermore, the EFR160T120 is designed with user convenience in mind. Maintenance is straightforward, and replacement parts are readily available, which facilitates easy repairs and servicing. Overall, the Bradford-White EFR160T120 water heater stands out as a reliable and efficient choice for homes that require ample hot water supply without sacrificing space or energy efficiency.