Bradford-White Corp TG237E-N(X), TG-237E-N(X)A, TG-150E-N(X), TG-180E-N(X) State Regulations

Page 12

State Regulations

NOTICE BEFORE INSTALLATION

Bradford White direct-vent appliance must be installed by a state qualified or licensed contractor. If you are not properly trained, you must not install this unit.

IMPORTANT: In the State of Massachusetts (248CMR 4.00 & 5.00)

For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of venting, including but not limited to decks and porches, the following requirements must be satisfied:

1.INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter must observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter must observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by side wall horizontal vented gas fueled equipment. It is the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors.

a.In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

b.In the event that the requirements of this subdivision cannot be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm must be installed.

2.APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.

3.SIGNAGE. A metal or plastic identification plate must be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign must read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.

4.INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5308(2)(a)1 through 4.

12

Image 12
Contents TG-150E-NX, TG-180E-NX, TG-199E-NX, TG237E-NX & TG-237E-NXA Table of Contents Page Page If YOU Smell GAS Section II Specifications ModelDimensions TG-150E TG-180E TG-199E Section III Installation Instructions Unpacking Water Heater LocationRemove Carton Mount Water Heater on the WallState Regulations Important In the State of Massachusetts 248CMR 4.00Installation Clearances Description Canadian Installations Inside Corner High Altitude Installations Section IV Water Connections Water QualityInstructions for Connections Page Approximate TIME/TEMPERATURE Relationships in Scalds Recommended Piping for a Basic Installation Recommended Piping for a Circulation Systems Recommended Piping for Power Failure Freeze Protection Recommended Piping for Freeze ProtectionPressure Relief Valve Page Page Section V GAS Connections GAS Meter Size Natural GAS only GAS Pressure RegulationGas Specific CorrectionInitial Operation and Testing Installer only Section VI Electrical Connections CPU Page Wiring Diagram for TG-237E-NXand TG-237E-NXAModels Temperature Controls Page Temperature Display Use Indicator Installation of ControlsInitial Operation and Testing of Controls Installer only Illustration Showing Where to Connect Remote Control HarnessTroubleshooting Electrical Wire ColorResistance Connector Pin Nos Heat Exchanger and Outgoing Water Temperature Thermistors Flame RodFrost Protection Amp FusesSection VII Operating Instructions General Instructions To Fill the Water HeaterSequence of Operation Lighting Instructions For Your Safety Read Before Operating Property damage, personal injury or loss of lifeWhat to do if YOU Smell GAS Operation InstructionsTemperature Adjustment Turning OFF the Water Heater for AN Extended Period of TimeTemperature Display Use Indicator Approximate TIME/TEMPERATURE Relationships in Scalds ScaldingFirst AID for Scalds Diagnostic Codes on the Temperature Control Display Code Code DescriptionCode Section Viii Maintenance Burner Flame AppearancePage Circulating Pump Water HeaterPage Section IX Parts List Description Quantity Page Description Quantity Page Description Quantity Page Description Quantity TG-237E Models TG-237E-N TG-237E-X TG-237E-NA TG-237E-XA Page Description Quantity Page Description Quantity Page Description Quantity Section X Warranty What will we do to correct problems? How do you get warranty assistance?What should you do to keep the warranty in effect? What will we not do?Page Page Page Fax/215-641-1670 Parts Fax/215-641-2180