18 |
| OPERATION & ADJUSTMENT INSTRUCTIONS |
| ||
| ||
|
|
|
Auto Close Timer: N/A
TS Operation
Open Button: Momentary activation; open override of closing door.
Close Button: Momentary activation.
Stop Button: Momentary activation; stops open, close or reverse action.
Single Button: Momentary activation to open; open override of closing door, closes door from
EP Reverse (Photo Input): Momentary activation will reverse a closing door, reverse to full open (ignores
Auto Close Timer: Closes door from
will reactivate the auto close timer or reset the auto close timer when the door is at the
T Operation, Dip-Switch Setting
Open Button: Momentary activation; open override of closing door.
Close Button: Momentary activation.
Stop Button: Momentary activation; stops open, close or reverse action.
Single Button: Momentary activation to open; open override of closing door, closes door from
EP Reverse (Photo Input): Momentary activation will reverse a closing door, reverse to full open (ignores
Auto Close Timer: Closes door from
SETUP MODES
Setup Modes
Various operating characteristics can be modified via the setup modes. The operator is moved to the close limit position and the
These values are set to factory defaults that should be satisfactory for many applications. ALL VALUES AS
DESCRIBED HERE CAN BE RESET TO THE FACTORY DEFAULTS AS FOLLOWS:
Remove 24 VAC power from the control board. Press and hold the
Delay on Reverse Setup
To help prevent stress on the door components, this feature allows for a delay time between the door stopping and reversing when a command to reverse is received as the door is closing. The factory default time is 0.75 seconds; the minimum time is 0.4 seconds; the maximum time is 2 seconds.
After moving the door to the close position and temporarily setting the switches to the appropriate settings in the table, pressing STOP will reset the time to the minimum setting. Every time OPEN is pressed, 200 mS is added to the time (up to the maximum).
Setup Mode | Switch | Switch | Switch | Switch |
| 1 | 2 | 3 | 4 |
|
|
|
|
|
Delay on Reverse | ON | ON | ON | ON |
|
|
|
|
|
Close Limit Delay | OFF | ON | ON | ON |
|
|
|
|
|
ON | OFF | ON | ON | |
|
|
|
|
|
Auto Close Timer | OFF | OFF | ON | ON |
|
|
|
|
|
Maximum Run | OFF | ON | OFF | ON |
Time |
|
|
|
|
|
|
|
|
|
Changing the
Close Limit Delay Setup
To provide for irregularities in the floor, this feature allows for the door to continue to travel down after the Reverse Cutout Limit is activated. The factory default time is 0.32 seconds; the minimum time is 0.12 seconds; the maximum time is 0.66 seconds.
After moving the door to the close position and temporarily setting the switches to the appropriate settings in the table, pressing STOP will reset the time to the minimum setting. Every time OPEN is pressed, 0.02 seconds are added to the time (up to the maximum).
Changing the