12 |
| INSTALLATION INSTRUCTIONS - ELECTRICAL WIRING |
| ||
| ||
|
|
|
WARNING
TO PREVENT THE RISK OF PERSONAL INJURY OR DEATH :
•DISCONNECT POWER AT THE FUSE BOX BEFORE PROCEEDING.
•ELECTRICAL CONNECTIONS MUST BE MADE BY A QUALIFIED INDIVIDUAL.
•OBSERVE LOCAL ELECTRICAL CODES WHEN WIRING THE OPERATOR.
WARNING: The
Observe local electrical codes when wiring the operator.
When hard wiring, observe state and local electrical codes. A wiring diagram is attached to the inside of the control box cover. Connect the appropriate voltage and phase power leads to the appropriate terminals as per the wiring diagram and connect a ground wire to the grounding screw. On three phase units, incorrect phasing of the power supply will cause the motor to rotate in the wrong direction (open when CLOSE button is pushed and vice versa). To correct this, interchange any two of the incoming three phase conductors.
The wiring diagram attached inside the cover of the control box details all of the field wiring terminal connections for the operator. Always connect the wires to the
Warning: Control voltage of the opener is 5 volts DC, Class 2. Do not run the power leads and control circuit wiring in the same electrical conduit.
WARNING
TO PREVENT THE RISK OF PERSONAL INJURY AND/OR DAMAGE TO DOOR OR PROPERTY, ONLY OPERATE DOOR CONTROL WHEN DOOR IS IN CLEAR VIEW. IF CONTROL STATION CANNOT BE LOCATED WHERE THE DOOR IS VISIBLE OR IF ANY OTHER DEVICE IS USED TO CONTROL THE DOOR AN AUXILIARY ENTRAPMENT DEVICE (DOOR EDGE OR PHOTOELECTRIC) MUST BE CONNECTED.
WARNING |
RISK OF ENTRAPMENT THAT MAY |
RESULT IN SERIOUS PERSONAL INJURY OR |
DEATH. DISCONNECT POWER TO THE |
OPENER BEFORE AND DURING |
INSTALLATION OF AN ACCESSORY |
REVERSING DOOR EDGE OR |
PHOTOELECTRIC DEVICE. DO NOT |
RECONNECT POWER TO OPENER UNTIL |
INSTRUCTED TO DO SO. ENSURE DOORWAY |
IS CLEAR BEFORE STARTING TESTING OF |
Note:
If the external entrapment protection device is connected, the selector switches are set properly (Page 17) and the device detects an obstruction or becomes inactive, an opening door continues to open and a closing door stops, pauses and starts open. While in this mode, if a problem is detected while the operator is stopped, a close will require constant activation of the control Close button. If an entrapment protection device as described above is attached and is properly working for 1 second, it will be auto detected and the monitored function will be turned on. Once the monitoring function is active, it will remain active even if the power is removed and the entrapment protection device is disconnected and power is restored. While in this mode, if a problem is detected while the operator is stopped, a close will require constant activation .
Operators which have an operational entrapment protection device as described above may have one or more additional means of control which should be wired in accordance with the diagram supplied in the opener and also illustrated on Pages 23 & 24. To add a second three button station, refer to Figure 11.
Number 22 gauge wire or heavier must be used for wiring the control stations and auxiliary control devices to the operator. Smaller gauge wire will cause operational problems, especially when multiple