IMPORTANT INSTALLATION INSTRUCTIONS! |
| 5 |
| ||
| ||
|
|
|
WARNING
TO REDUCE THE RISK OF SEVERE INJURY OR DEATH:
READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS!
•Install only on a properly operating and balanced garage door. A door that is operating improperly could cause severe injury. Have qualified service personnel make repairs to cables, spring assemblies and other hardware before installing the opener.
•Remove all pull ropes and remove, or make inoperative, all locks (unless mechanically and/or electrically interlocked to the power unit) that are connected to the garage door before installing the opener.
•Lightweight doors (fiberglass, aluminum etc.) must be reinforced to avoid door damage. Check the door manufacturer’s instruction manual for a bracing procedure or the availability or a Reinforcement Kit.
•Model AUJ and AUH are Commercial Vehicular Door Operators and as such ARE NOT recommended for pedestrian traffic. In installations where it is known that pedestrians will be nearby ensure a pedestrian door is available for entrance and exit to the building. In addition YOU MUST install an auxiliary entrapment protection device (reversing door edge or photoelectric beam device).
•Connect an auxiliary entrapment protection device (reversing edge or photoelectric device across the door opening). A device of this type is STRONGLY ADVISED FOR ALL commercial operator installations. An auxiliary entrapment protection device is REQUIRED when the three button control station is out of sight of the door or any other automatic or manual control is used.
•Install the door operator at least 8 feet or more above the floor if the operator has exposed moving parts.
•Do not connect the opener to the source of power until instructed to do so.
•Locate the control station:
a)within sight of the door,
b)at a minimum height of five feet above the floor so small children cannot reach it,
c)away from all moving parts of the door, and
d)far enough away from the door, or positioned
such that the user is prevented from coming in contact with the door while operating the controls.
Do not overtighten the clutch adjustment to compensate for a poorly working door.
Install the Entrapment Warning Placard next to the control station in a prominent location.
All warning signs and placards must be installed so they are visible in the area of the door.
After installing the opener, all safety features must be tested for proper operation (see page 22).
For products having a manual release, instruct the end user on the operation of the manual release.
COMPONENT IDENTIFICATION LISTING
ITEM # | PART# | DESCRIPTION | QUAN. | ITEM # | PART# | DESCRIPTION | QUAN | ||
| 1 |
| Operator Power Head | 1 | 6 | 100413 | 1/4” Square Key | 2 | |
2 | 005031 | 3 Button St ation | 1 | 7 | 006119 | 4 | |||
3 |
| 30 | Tooth Sprocket, 1” Bore, 1/4 Key | 1 | 8 | 105323 | Steel #80 Release Chain | AR | |
4 |
| 20 | Tooth Sprocket, 1” Bore, 1/4 key | 1 | 9 | 100315 | #3 Hand Chain - Precut to 26 Ft. | 1 | |
5 | 105193 | Release/Hand Chain Wall Bracket | 1 | 10 |
| Drive Chain to Door Shaft, 4 Ft. | 1 | ||
|
|
|
|
|
| 11 |
| 3 Piece Chain Connecting Link | 1 |
——AR - As Required