C:INSTALLING THE OPERATOR
OPTIONAL SAFE FINISH PHOTOSYSTEM INSTALLATION
NOTE: Skip to Step 15 on Page 13 if not installing a Safe Finish Photosystem at this time.
Identify which side of the garage door opening (if any) the sun is “likely” to shine into. As sunlight may cause undesirable operation, mount the sending unit (black button below the window) on the side of the door opening exposed most to the sun.
12 Inches From Door Opening
#8 Hex |
Head
Screw
STEP 10: Mounting the Photosystem Wall Brackets Select a mounting
position 5 inches above the floor to the center line wall bracket. The sending and |
|
|
| |||
receiving units should be mounted inside | the door opening to minimize any |
|
| 1/4” x | ||
5 Inches | ||||||
| interference | by the sun. However, the sensors | Above the Floor |
| Lag Screw | |
104382 | ||||||
should be mounted as close to the door track or |
|
|
| |||
|
|
|
| |||
|
|
|
|
inside edge of the door as possible to offer maximum entrapment protection. The brackets
may be temporarily mounted to the wall (or jamb) with the 1” flathead nail provided. Leave this nail in place after installation of the lag screw below to prevent accidental rotation of the bracket NOTE:
It is very important that the wall brackets be mounted at exactly the same height so they will be
aligned.
Using the 1/4” x
materials other than wood or gypsum. Repeat for the wall bracket on the other side of the opening.
STEP 11: Wire Connect the Photosystem
Refer to page 20 for wiring diagrams of the Safe Finish™ Photosystem and garage door opener. The following outlines the “PHOTOCELL SERIES CONNECTION (RECEIVER FIRST)” wiring diagram.
A.Run a wire pair (not supplied) around the garage door jamb between the transmitter and receiver "L" mounting brackets. NOTE: Leave about 12” of extra wire at each end. Use a minimum 22 gauge solid "trace" wire (one wire in set should be marked to identify it at each end) for interconnect.
B.Run a wire pair (20 or 22 gage solid wire) from the receiver position (unit with "LED" light in the front, may be either side of the door) back to the rear bulkhead of the garage door opener. NOTE: Leave about 12” of extra wire at the receiver end and about 24” of extra wire at the opener end. Use a minimum 22 gauge solid "trace" wire (one wire in set should be marked to identify it at each end) for interconnect.
C.Strip approximately 5/16” from each wire end at the photosystem units and at the opener.
D.Using two (2) wire nuts (supplied), connect the wire ends at the Safe Finish™ Photosystem transmitter to the pigtail wire ends coming out of the transmitter unit. Observe polarity, connect the trace wire ends (with black stripe) together and the unmarked wire ends together. See wiring diagrams on page 20 .
Using two (2) wire nuts (supplied), connect the wire ends at the SAFE FINISH™ Photosystem receiver to the pigtail wire ends coming out of the receiver unit. Observe polarity, connect the trace wire ends (with black stripe) together and the unmarked wire
ends together.
STEP 12 : Final Installation of Photosystem Units | 104383 |
|
A.Attach the"U" brackets to the "L" brackets with a
B.Place the transmitter and receiver units into their respective "U"
brackets. NOTE: It is easier to slip the photosystem units in from the side of the bracket than forcing them in from the front of the bracket. See Illustration, at right.
C.Connect the interconnect wire pair to the garage door opener terminals.
Connect the trace wire (black stripe) to the operator terminal marked “4” and the solid color wire to the operator terminal marked “5”. See Wiring Diagrams on page 20 .