Allstar Products Group LT 50 owner manual Optional Safe Finish Photosystem Installation

Page 11

C:INSTALLING THE OPERATOR

OPTIONAL SAFE FINISH PHOTOSYSTEM INSTALLATION

NOTE: Skip to Step 15 on Page 13 if not installing a Safe Finish Photosystem at this time.

Identify which side of the garage door opening (if any) the sun is “likely” to shine into. As sunlight may cause undesirable operation, mount the sending unit (black button below the window) on the side of the door opening exposed most to the sun.

12 Inches From Door Opening

#8 Hex

110052-1

Head

Screw

STEP 10: Mounting the Photosystem Wall Brackets Select a mounting

position 5 inches above the floor to the center line wall bracket. The sending and

 

 

 

receiving units should be mounted inside

the door opening to minimize any

 

 

1/4” x 1-1/2”

5 Inches

 

interference

by the sun. However, the sensors

Above the Floor

 

Lag Screw

104382

should be mounted as close to the door track or

 

 

 

 

 

 

 

 

 

 

 

inside edge of the door as possible to offer maximum entrapment protection. The brackets

may be temporarily mounted to the wall (or jamb) with the 1” flathead nail provided. Leave this nail in place after installation of the lag screw below to prevent accidental rotation of the bracket NOTE:

It is very important that the wall brackets be mounted at exactly the same height so they will be

aligned.

Using the 1/4” x 1-1/2” lag screw provided, attach the wall bracket securely to the wall. In some installations it may be necessary to attach wooden spacers to the wall to achieve the required clearance. Expansion bolts (not supplied) may be required to attach brackets to walls constructed of

materials other than wood or gypsum. Repeat for the wall bracket on the other side of the opening.

STEP 11: Wire Connect the Photosystem

Refer to page 20 for wiring diagrams of the Safe Finish™ Photosystem and garage door opener. The following outlines the “PHOTOCELL SERIES CONNECTION (RECEIVER FIRST)” wiring diagram.

A.Run a wire pair (not supplied) around the garage door jamb between the transmitter and receiver "L" mounting brackets. NOTE: Leave about 12” of extra wire at each end. Use a minimum 22 gauge solid "trace" wire (one wire in set should be marked to identify it at each end) for interconnect.

B.Run a wire pair (20 or 22 gage solid wire) from the receiver position (unit with "LED" light in the front, may be either side of the door) back to the rear bulkhead of the garage door opener. NOTE: Leave about 12” of extra wire at the receiver end and about 24” of extra wire at the opener end. Use a minimum 22 gauge solid "trace" wire (one wire in set should be marked to identify it at each end) for interconnect.

C.Strip approximately 5/16” from each wire end at the photosystem units and at the opener.

D.Using two (2) wire nuts (supplied), connect the wire ends at the Safe Finish™ Photosystem transmitter to the pigtail wire ends coming out of the transmitter unit. Observe polarity, connect the trace wire ends (with black stripe) together and the unmarked wire ends together. See wiring diagrams on page 20 .

Using two (2) wire nuts (supplied), connect the wire ends at the SAFE FINISH™ Photosystem receiver to the pigtail wire ends coming out of the receiver unit. Observe polarity, connect the trace wire ends (with black stripe) together and the unmarked wire

ends together.

STEP 12 : Final Installation of Photosystem Units

104383

 

A.Attach the"U" brackets to the "L" brackets with a 1/4-20 carriage bolt, washer and hex nut (provided). Insert the bolt from the inside of the "U" bracket and hand tighten only at this time.

B.Place the transmitter and receiver units into their respective "U"

brackets. NOTE: It is easier to slip the photosystem units in from the side of the bracket than forcing them in from the front of the bracket. See Illustration, at right.

C.Connect the interconnect wire pair to the garage door opener terminals.

Connect the trace wire (black stripe) to the operator terminal marked “4” and the solid color wire to the operator terminal marked “5”. See Wiring Diagrams on page 20 .

11

Image 11 Contents
Allstar LT Table of Contents Optional Features Product FeaturesStandard Features Tools Required Component IdentificationAssembly Instructions Page Reinforce the Header Wall Installing the OperatorSectional Doors and ONE-PIECE Doors With Track Door Bracket Installation Mount Power Head to CeilingProvided to Terminals 1 & 0 on the Openers rear Install a Rough Service lamp bulb 75 WattConnecting The Electrical Power Connect the standard wall Push ButtonMounting the Photosystem Wall Brackets Select a mounting Optional Safe Finish Photosystem InstallationWire Connect the Photosystem Final Installation of Photosystem UnitsAlignment and Initial Test of Safe Finish Photosystem AT this Point Plug Connect the Power to the OperatorConnecting the Door Arm to the Door Connecting Door Arm to TrolleyPhotoelectric Obstruction Test Important Test Opener Obstruction Sensing FeatureTance is inadequate Try moving Adjustment #3 Obstruction Sensing at Close Limit Position AdjustmentsAdjustment #1 Opening Travel Adjustment #2 Opening and Closing ForceChecking the Travel Timer Adjustments / Important Safety InstructionsAdjustment #3 Obstruction Sensing Closing Direction Adjustment #4 Positive Mechanical Lock AdjustmentOperation of Your Opener Operating InstructionsOptional Three Function Wall Station HOW to Operate the Door Manually Manual Release DisconnectOptional Pneumatic Door Edge Installation Safe Finish Wiring Diagram / Door Edge InstallationInstallation Checklist Maintenance Schedule / Installation ChecklistMaintenance of Your Opener Symptom Probable CAUSE/SOLUTION Troubleshooting GuideParts Breakdown & Listing Allstar Corporation Downingtown, PA Manufacturer’s Limited Warranty