Echo WP-1000 T1E manual Starting cold engine

Page 14

14

warning

Water can be conductor of electric current when exposed to live electrical wiring. Electrocution will result.

Do not operate pump in flooded basements without first shutting off electricity from outside the house. Pump should be located outside in a vented area.

Do not operate pump in flooded areas near power lines unless electric service has been disconnected.

IMPORTANT

Prolonged pumping of water containing sludge mud and gravel will cause rapid wear to impeller or internal pump parts. Pump only clear water.

Pump suction lift is affected by water temperatures. Maximum temperature of water should be 60o C (140o F), or lower.

Internal pump body components will corrode if the pump is used to pump liquids high in acidity or alkaline.

starting cold engine

warning

Do not run engine in an enclosed area. Exhaust gas contains carbon monoxide, an odorless and deadly poison.

IMPORTANT

Do not start or run the pump without priming the pump with wa- ter. Serious damage to the pump seals will occur when the pump is run dry.

1.Place suction intake and strainer in the water to be pumped prior to starting engine.

2.Place ignition switch (A) in Start/Run position.

3.Move choke (B) to Cold Start ( ) Position.

4.Pump primer bulb (C) until fuel is visible and flows freely in the clear fuel tank return line. Pump bulb an additional 4 or 5 times.

5.Move throttle lever (D) towards engine to idle position.

6.Pull starter handle (E) until engine fires (5 ~ 6 pulls maximum).

7.After engine fires (or 5 ~ 6 pulls), move choke lever (B) to Run

( ) position and pull recoil starter handle/rope until engine starts and runs. Allow unit to warm up at idle for several minutes.

NOTE

If engine does not start with choke in “Run” position after 5 pulls, repeat instructions.

8.Place throttle lever (D) in half throttle position until pump begins to pump water. Then move lever to full throttle.

B

A

E

C

D

Image 14
Contents Water Pump Operators manual Table of ContentsIntroduction Safety Manual Safety Symbols and Important Information Water Pump Operators ManualTypical pump applications International symbolsPersonal condition and safety equipment Eye Protection Physical ConditionProper Clothing Hand ProtectionEmission Control exhaust & evaporative EPA 2010 and Later and/or C.A.R.B. TierEquipment Hot Decal near muffler DescriptionPage Contents Assembly suction hoseDischarge hose Garden HoseFuel Fuel RequirementsOperation Handling Fuel Mixing InstructionsPriming the pump Starting cold engine Cold weather operation Starting warm engineStopping engine Maintenace intervals MaintenanceSkill levels Air filter Fuel filterSpark plug Cooling systemSpark Arrestor Screen Exhaust systemExhaust Port Cleaning High Altitude Operation Carburetor adjustmentEngine Break-In Emission models with limiter capsFine Tuning Requires Accurate Tachometer Idle Speed AdjustmentBasic Setting Non Emissions Models Without Limiter CapsPump casing Troubleshooting Engine Problem Troubleshooting ChartStorage Troubleshooting pump endLong Term Storage over 30 days Removing Pump from Storage Specifications Water Pump Operator s ManualWarranty Statements Exceptions99922201032 11/18/2011 Page Water Pump Operators Manual Servicing Information parts/serial number ServiceWarranty registration Additional or replacement manuals Echo consumer product support