Echo WP-1000 T1E manual Exhaust Port Cleaning

Page 20

20

Exhaust Port Cleaning

Level 2.

Parts Required: As needed: Heat Shield

1.Remove engine cover. See “Cleaning Cooling System” for step by step instructions..

2.Place piston at top dead center. Remove muffler (A) and heat shield (B).

3.Use a wood or plastic scraping tool to clean deposits from cylinder exhaust port.

IMPORTANT

Never use a metal tool to scrape carbon from the exhaust port. Do not scratch the cylinder or piston when cleaning the exhaust port. Do not allow carbon particles to enter the cylinder.

4.Inspect heat shield, and replace if damaged.

5.Install heat shield and muffler.

6.Tighten muffler mounting bolts (or nuts) to 50-55 in•lbf

(55-65 kgf•cm).

7.Install engine cover and attach spark plug lead and throttle cable.

8.Start engine, and warm to operating temperature.

9.Stop engine, and re-tighten mounting bolts (or nuts) to specifica- tions.

BA

Image 20
Contents Water Pump Operators manual Table of ContentsIntroduction Safety Manual Safety Symbols and Important Information Water Pump Operators ManualTypical pump applications International symbolsPersonal condition and safety equipment Physical Condition Proper ClothingEye Protection Hand ProtectionEmission Control exhaust & evaporative EPA 2010 and Later and/or C.A.R.B. TierEquipment Hot Decal near muffler DescriptionPage Contents Assembly suction hoseDischarge hose Garden HoseFuel Fuel RequirementsOperation Handling Fuel Mixing InstructionsPriming the pump Starting cold engine Cold weather operation Starting warm engineStopping engine Maintenace intervals MaintenanceSkill levels Air filter Fuel filterSpark plug Cooling systemSpark Arrestor Screen Exhaust systemExhaust Port Cleaning Carburetor adjustment Engine Break-InHigh Altitude Operation Emission models with limiter capsIdle Speed Adjustment Basic SettingFine Tuning Requires Accurate Tachometer Non Emissions Models Without Limiter CapsPump casing Troubleshooting Engine Problem Troubleshooting ChartStorage Troubleshooting pump endLong Term Storage over 30 days Removing Pump from Storage Specifications Water Pump Operator s ManualWarranty Statements Exceptions99922201032 11/18/2011 Page Water Pump Operators Manual Service Warranty registration Additional or replacement manualsServicing Information parts/serial number Echo consumer product support