Problem | Possible Causes | What To Do |
Salty tasting water | Insufficient backwash and | •Increase backwash time. See the Service: Regeneration and |
after installation | rinse time | Heavy Duty Backwash section. |
|
|
|
| Low water pressure | •Check pressure; should be minimum 20 psi. |
|
|
|
| Restricted drain hose | •Clean and reconnect hose. |
|
|
|
Resin beads showing | Cracked distributor | •Call for service. |
up in drinking water |
|
|
and sink |
|
|
|
|
|
Sounds you might hear | Running water from the unit into | •This is normal. |
| a drain |
|
|
|
|
Water has air bubbles | Air in system after installation | •Will go away after it runs for a while. |
and is cloudy |
|
|
|
|
|
Error Code on control | Wiring may have worked loose | •Unplug transformer. |
| in control | •Remove control cover, release clips on side. |
|
| |
|
| •Check for loose/incorrect wiring connections to electronic |
|
| board or switch. Reconnect as required. |
|
| •Reassemble control cover. |
|
| •Plug in Transformer. |
|
| •Wait six minutes for Error Code to reappear. |
|
| •If Error Code reappears call for service. |
25