Step-by-step installation instructions.
• Turn off the gas or electric supply to the water heater, in | Fig. 3 | Clips |
the possibility that the water heater may be drained while |
|
|
draining pipes. |
|
|
• Turn off the water supply to pipes to be cut and drain the |
| |
house water pipes. |
| |
|
|
• Open both hot and cold faucets.
1
Install bypass valve:
•Remove plastic shipping plug and retainer from valve outlet.
Turbine
Valve outlet
Turbine support and shaft
NOTE: Be sure the turbine and support are firmly in place, in the valve outlet. Blow into the valve port and observe the turbine for free rotation.
•Push the bypass valve (lubricate
IMPORTANT:
•Snap the 2 large plastic clips in place, as shown in Fig. 3. Be sure they snap into place. Pull on the bypass valve to make sure it is held securely in place.
Fig. 4
Valve drain hose (female garden hose fitting)
Drain fitting on valve (Male garden hose fitting)
Tie or wire hose in place
STANDPIPE |
LAUNDRY TUB |
SUMP |
2 Move the softener assembly into installation position:
CAUTION:
•Secure the resin tank to a stable structure to prevent it from falling over.
•Locate the brine tank directly next to the resin tank.
•Be sure the installation surface is level and smooth. Sharp
objects under the brine tank may puncture it. If needed, place the brine tank on a section of 3/4″ thick (minimum) plywood. Then, place shims under the plywood as needed to level the softener.
•Connect the black brine valve tube from the brinewell to the venturi assembly on the valve, using the plastic nut provided as shown in Fig. 5.
3 Plumb IN and OUT pipes to and from softener:
CAUTION: Observe all of the following cautions as you connect inlet and outlet plumbing.
•Be sure incoming hard water supply is directed to the softener valve inlet port. If house water flow is from the left, use a plumbing
•Do all sweat soldering before connecting pipes to the bypass valve. Torch heat will damage plastic parts.
•When turning threaded pipe fittings onto plastic fittings, use care not to
•Use pipe joint compound on all external pipe threads.
FLOOR DRAIN 11⁄2″ air gap
•Support inlet and outlet plumbing in some manner (use pipe hangers) to keep the weight off of the valve fittings.
4 Connect and run the valve drain hose:
•Take a length of garden hose with female fitting and attach to the valve drain fitting, as shown in Fig. 4.
IMPORTANT: Make sure the garden hose fitting fits securely onto the threaded drain port.
•Locate the other end of the hose at a suitable drain point (floor drain, sump, laundry tub, etc.) that terminates at the sewer drain. Check and comply with local codes.
IMPORTANT: Use a high quality,
•Tie or wire the hose in place at the drain point. High water pressure will cause it to whip during the
rinse cycles of regeneration. Also provide an air gap of at least
•If raising the drain hose overhead is required to get to the drain point, do not raise higher than 8´ above the floor.
Elevating the hose may cause a
7