Step-by-step installation instructions.

Turn off the gas or electric supply to the water heater, in

Fig. 3

Clips

the possibility that the water heater may be drained while

 

 

draining pipes.

 

 

Turn off the water supply to pipes to be cut and drain the

 

O-rings

house water pipes.

 

 

 

Open both hot and cold faucets.

1

Install bypass valve:

Remove plastic shipping plug and retainer from valve outlet.

Turbine

Valve outlet

Turbine support and shaft

NOTE: Be sure the turbine and support are firmly in place, in the valve outlet. Blow into the valve port and observe the turbine for free rotation.

Push the bypass valve (lubricate o-ring seals with silicone grease) into both ports of the valve as shown in Fig. 3.

IMPORTANT:

Snap the 2 large plastic clips in place, as shown in Fig. 3. Be sure they snap into place. Pull on the bypass valve to make sure it is held securely in place.

Fig. 4

Valve drain hose (female garden hose fitting)

Drain fitting on valve (Male garden hose fitting)

Tie or wire hose in place

STANDPIPE

LAUNDRY TUB

SUMP

2 Move the softener assembly into installation position:

CAUTION:

Secure the resin tank to a stable structure to prevent it from falling over.

Locate the brine tank directly next to the resin tank.

Be sure the installation surface is level and smooth. Sharp

objects under the brine tank may puncture it. If needed, place the brine tank on a section of 3/4″ thick (minimum) plywood. Then, place shims under the plywood as needed to level the softener.

Connect the black brine valve tube from the brinewell to the venturi assembly on the valve, using the plastic nut provided as shown in Fig. 5.

3 Plumb IN and OUT pipes to and from softener:

CAUTION: Observe all of the following cautions as you connect inlet and outlet plumbing.

Be sure incoming hard water supply is directed to the softener valve inlet port. If house water flow is from the left, use a plumbing cross-over as shown in Fig. 1.

Do all sweat soldering before connecting pipes to the bypass valve. Torch heat will damage plastic parts.

When turning threaded pipe fittings onto plastic fittings, use care not to cross-thread.

Use pipe joint compound on all external pipe threads.

FLOOR DRAIN 112air gap

Support inlet and outlet plumbing in some manner (use pipe hangers) to keep the weight off of the valve fittings.

4 Connect and run the valve drain hose:

Take a length of garden hose with female fitting and attach to the valve drain fitting, as shown in Fig. 4.

IMPORTANT: Make sure the garden hose fitting fits securely onto the threaded drain port.

Locate the other end of the hose at a suitable drain point (floor drain, sump, laundry tub, etc.) that terminates at the sewer drain. Check and comply with local codes.

IMPORTANT: Use a high quality, thick-walled hose that will not easily kink or collapse. The water softener will not work if water cannot exit this hose during regenerations.

Tie or wire the hose in place at the drain point. High water pressure will cause it to whip during the back-wash and fast

rinse cycles of regeneration. Also provide an air gap of at least 1–1/2between the end of the hose and the drain point. An air gap prevents possible siphoning of sewer water into the softener, if the sewer should back-up.

If raising the drain hose overhead is required to get to the drain point, do not raise higher than 8´ above the floor.

Elevating the hose may cause a back-pressure that could reduce brine draw during regenerations.

7

Image 7
Contents 7221039 Water Softening systemTwo easy ways to register your appliance GE & You, a Service PartnershipSafety Precautions Important Installation Recommendations Installation instructionsUnpacking and Inspection Where to Install the Softener Plan How You Will Install the SoftenerTools and Materials Required for Installation Typical Installation Illustration Optional 3-Valve Bypass Installation IllustrationPlumb in and OUT pipes to and from softener Step-by-step installation instructionsInstall bypass valve Move the softener assembly into installation positionConnect to electrical power Install the brine tank overflow fittings and hoseInstall grounding clamps and wire Installation for water leaksSet present time of day Programming the ControlSet water hardness number Sanitizing Procedures GNSF39A GNSF48A About the water softener system Breaking a Salt Bridge Cleaning the Nozzle and Venturi Assembly Feature Optional Recharge Controls Normal Operation, Timer DisplayFeature Program Memory ERR Feature/Service Automatic Electronic DiagnosticsFeature Other Data Displays To remove an error code 1 Unplug transformerNo Soft Water Timer/Softener, Service Checkout ProcedureOpen a Nearby Soft Water Faucet If the water softening system does not draw brine, check SET Time Cleaning Iron Out of the Water Softening System Care and cleaning of the water softening systemChecking the Salt Storage Level and Refilling Problem Possible Causes What To Do No soft water Before you call for service…Water is blue color After installation Water softening systemNot using any salt Water feels slipperyResin beads showing After installationIs cloudy Error Code on control Salty tasting waterParts list 999 Parts catalog PLUG, Fill FLOW, .3 GPM Page Page Page We’ll Cover Any Appliance. Anywhere. Anytime Consumer Product Ownership Registration Warrantor General Electric Company. Louisville, KY GE Water Softening System WarrantyFor The Period GE Will Replace What GE Will Not CoverGE Answer Center Service Telephone Numbers