Plan How You Will Install the Softener

You must first decide how to run in and out pipes to the softener. Look at the house main water pipe at the point where you will connect the softener. Is the pipe soldered copper, glued plastic, or threaded galvanized? What is the pipe size?

WARNING: Use only lead-free solder and flux to prevent lead poisoning.

See Typical Installation Illustration, Fig.1. Use this as a guide when planning your particular installation.

Be sure to direct the incoming hard water supply to the softener valve inlet fitting. The valve is marked IN and OUT. See below to help you prepare.

Where to Install the Softener

Place the softener as close as possible to a sewer drain, or other acceptable drain point or standpipe.

It is recommended to keep outside faucets on hard water to save soft water and salt.

Do not install the softener in a place where it could freeze. Freeze damage is not covered by the warranty.

Do not install the softener where it would block access to the water heater or access to the main water shutoff.

Do not locate the brine tank more than 10 feet away from the resin tank.

Put the softener in a place where water damage is least likely to occur if a leak develops. The manufacturer will not repair or pay for water damage.

A 120 volt electric outlet is needed to plug in the included transformer. The softener has a 10 foot power cable. If the outlet is remote (up to 100 feet), use 18 gauge wire to connect. Be sure the electric outlet and transformer are in an inside location, to protect from wet weather. Be sure the outlet is unswitched to prevent accidental shutoff.

If installing in an outside location, you must take the steps necessary to assure the softener, installation plumbing, wiring, etc., are as well protected from the elements (sunlight, rain, wind, heat, cold), contamination, vandalism, etc., as when installed indoors.

Keep the softener out of direct sunlight. The sun’s heat may distort non-metallic parts and may damage the electronics.

Tools and Materials Required for Installation

In and out fittings included with the softener are 1″ (nominal) copper sweat tubes. To maintain full valve flow, 1″ pipes to and from the softener fittings are recommended. You should maintain the same, or larger, pipe size as the water supply pipe, up to the softener inlet and outlet.

Use the included bypass valve to install the softener. The bypass valve allows you to turn off water to the softener for servicing, but still have water in the house pipes. The in and out fittings referred to above connect to the bypass valve with the included nuts and washers.

Use copper, brass or galvanized pipe and fittings. Some codes may also allow CPVC plastic pipes.

If additional drain hose is needed for salt tank drains, it can be ordered from GE Parts at 800.626.2002.

Garden hose with female fitting is needed for valve drain (sufficiently long to reach suitable drain).

If a rigid valve drain is needed to comply with plumbing codes, you can buy the parts needed to connect a 1/2″ copper tubing or plastic drain.

Clean nugget or pellet water softener salt is needed to fill the brine tank, see Step 8 in the Step-by-Step Installation Instructions.

5

Image 5
Contents 7221039 Water Softening systemTwo easy ways to register your appliance GE & You, a Service PartnershipSafety Precautions Unpacking and Inspection Installation instructionsImportant Installation Recommendations Tools and Materials Required for Installation Plan How You Will Install the SoftenerWhere to Install the Softener Typical Installation Illustration Optional 3-Valve Bypass Installation IllustrationInstall bypass valve Step-by-step installation instructionsMove the softener assembly into installation position Plumb in and OUT pipes to and from softenerInstall grounding clamps and wire Install the brine tank overflow fittings and hoseInstallation for water leaks Connect to electrical powerSet water hardness number Programming the ControlSet present time of day Sanitizing Procedures GNSF39A GNSF48A About the water softener system Breaking a Salt Bridge Cleaning the Nozzle and Venturi Assembly Feature Program Memory Normal Operation, Timer DisplayFeature Optional Recharge Controls Feature Other Data Displays Feature/Service Automatic Electronic DiagnosticsTo remove an error code 1 Unplug transformer ERRNo Soft Water Timer/Softener, Service Checkout ProcedureOpen a Nearby Soft Water Faucet If the water softening system does not draw brine, check SET Time Checking the Salt Storage Level and Refilling Care and cleaning of the water softening systemCleaning Iron Out of the Water Softening System Problem Possible Causes What To Do No soft water Before you call for service…Not using any salt After installation Water softening systemWater feels slippery Water is blue colorIs cloudy Error Code on control After installationSalty tasting water Resin beads showingParts list 999 Parts catalog PLUG, Fill FLOW, .3 GPM Page Page Page We’ll Cover Any Appliance. Anywhere. Anytime Consumer Product Ownership Registration For The Period GE Will Replace GE Water Softening System WarrantyWhat GE Will Not Cover Warrantor General Electric Company. Louisville, KYGE Answer Center Service Telephone Numbers