Care and cleaning of the water softening system.

Checking the Salt Storage Level and Refilling

Brine (salt dissolved in water) is needed for each and every regeneration. The water for making brine is metered into the salt storage area by the water softening system valve and control. However, you must keep the tank supplied with salt.

When to refill with salt: Check the salt level a few weeks after you install the water softening system and every week after that. Refill when the brine tank is from 1/3 to 1/2 full. Never allow the water softening system to use all the salt before you refill it. Without salt, you will soon have hard water.

Use clean water softening salts only, at least 99.5% pure. NUGGET, PELLET or coarse SOLAR salts are recommended. Do not use rock, block, granulated or ice cream making salts. They contain dirt and sediments, or mush and cake, and will create maintenance problems.

CAUTION: Water softening salt with iron removing additives: Some salts may have an additive to help the water softening system handle iron in the water supply. Although this additive may help to keep the water softening system resin clean, it may also release corrosive fumes that weaken and shorten the life of some water softening system parts. GE recommends using only Diamond Crystal ® Red•Out ® brand salt.

Cleaning Iron Out of the Water Softening System

Your water softening system takes hardness minerals (calcium and magnesium) out of the water. Also, it can control some (see Specification Guidelines section) “clear water” iron. With clear water iron, water from a faucet is clear when first put into a glass. After 15 to 30 minutes, the water begins to cloud or turn rust colored.

A water softening system will not remove any iron that makes the water cloudy or rusty as it comes from the faucet (called red water iron). To take red water iron out of water, or over the maximum of clear water iron, an iron filter or other equipment is needed.

GE recommends using only Diamond Crystal® Red•Out® brand salts with Iron Fighter® additive to help keep the resin bed clean of clear iron. If your water supply has clear water iron, periodic resin bed cleaning is needed. GE recommends using Super Iron Out® brand resin bed cleaner to thoroughly clean your resin bed if your iron content is high. Clean the bed at least every six months, or more often if iron appears in the soft water between cleanings.

IMPORTANT: It is important to mix the resin bed cleaner with water (following the manufacturer’s instructions), pour it into the brine well (see page 6) and regenerate the softener immediately. Do not pour the resin bed cleaner in with the salt, as it will not be as effective in cleaning the resin, and can cause damage to the softener if it is left in the brine tank for an extended period due to the corrosive gases that are formed.

22

Image 22
Contents Water Softening system 7221039GE & You, a Service Partnership Two easy ways to register your applianceSafety Precautions Important Installation Recommendations Installation instructionsUnpacking and Inspection Where to Install the Softener Plan How You Will Install the SoftenerTools and Materials Required for Installation Optional 3-Valve Bypass Installation Illustration Typical Installation IllustrationMove the softener assembly into installation position Step-by-step installation instructionsInstall bypass valve Plumb in and OUT pipes to and from softenerInstallation for water leaks Install the brine tank overflow fittings and hoseInstall grounding clamps and wire Connect to electrical powerSet present time of day Programming the ControlSet water hardness number Sanitizing Procedures GNSF39A GNSF48A About the water softener system Breaking a Salt Bridge Cleaning the Nozzle and Venturi Assembly Feature Optional Recharge Controls Normal Operation, Timer DisplayFeature Program Memory To remove an error code 1 Unplug transformer Feature/Service Automatic Electronic DiagnosticsFeature Other Data Displays ERRTimer/Softener, Service Checkout Procedure No Soft WaterOpen a Nearby Soft Water Faucet If the water softening system does not draw brine, check SET Time Cleaning Iron Out of the Water Softening System Care and cleaning of the water softening systemChecking the Salt Storage Level and Refilling Before you call for service… Problem Possible Causes What To Do No soft waterWater feels slippery After installation Water softening systemNot using any salt Water is blue colorSalty tasting water After installationIs cloudy Error Code on control Resin beads showingParts list 999 Parts catalog PLUG, Fill FLOW, .3 GPM Page Page Page We’ll Cover Any Appliance. Anywhere. Anytime Consumer Product Ownership Registration What GE Will Not Cover GE Water Softening System WarrantyFor The Period GE Will Replace Warrantor General Electric Company. Louisville, KYService Telephone Numbers GE Answer Center