About the water softener system.
On
LAST RECHARGE
WATER MANAGEMENT SYSTEM
Turbine
Switch Turbine count
Valve | Minutes of cycle |
position | remaining |
Fill
TIME
WATER MANAGEMENT SYSTEM |
Turbine |
RECHARGE
WATER MANAGEMENT SYSTEM
x 10
DAY
Service: Manually Initiated Electronic Diagnostics
1 To enter diagnostics, press and hold the DATA button until the display appears as shown.
NOTE: If the softener is in the middle of a regeneration, top part of the display shows the cycle of regeneration and minutes of the cycle remaining. If two cycle names are flashing, the valve is in transition between the cycles.
AThe three digits under WATER MANAGEMENT SYSTEM indicate water meter operation as follows:
■000 (steady) = soft water not in use…no flow through the meter.
—OPEN A NEARBY SOFT WATER FAUCET—
■000 to 140 (continual) = repeats display for each gallon of water passing through the meter.
| Motor |
Position |
|
switch |
|
| Sensor |
| housing |
| Turbine |
Valve | Turbine |
support | |
outlet | & shaft |
If you don’t get a reading in the display, with faucet open, pull the sensor from the valve outlet port. Pass a small magnet back and forth in front of the sensor. You should get a reading in the display. If you get a reading, shut off water supply, unhook the in and out plumbing and check the turbine for binding.
B This display segment ( ), in the following chart, indicates an open POSITION switch. Use the TOUCH or HOLD button to manually advance the valve into each cycle and check correct switch operation.
CORRECT SWITCH |
| ||||
| DISPLAYS | VALVE CYCLE STATUS | |||
|
|
|
|
| Valve in service, fill, brining, backwash |
|
|
|
|
| or fast rinse position. |
|
|
|
|
| Valve rotating from one position to another. |
|
|
|
|
|
|
|
|
|
|
|
|
2 Press the DATA button again. This diagnostic display shows the total number of recharges (top) since the timer was connected to electrical power.
The number of days since the timer was connected to electrical power is shown in the bottom part of the display. If over 1999 days, a (x10) indicator shows, meaning you must multiply the number shown by 10.
3 Press DATA once again to return the present time to the display.