Timer/Softener, Service Checkout Procedure
If you are not getting soft water, and an error code is not displayed, use the procedures below to find the problem. First make the following visual checks.
VISUAL CHECKS:
1
2
3
4
Is there electrical power to the outlet the water softening system transformer is plugged into?
Is there sufficient salt in the storage tank?
Is the plumbing bypass valve directing water for soft water service?
Is the valve drain hose open to the drain, not elevated too high, and unobstructed?
If you do not find a problem with the visual checks, continue below.
NO SOFT
WATER
TIMER SHOWS WRONG TIME AND DAY, AND/OR IS FLASHING.
Electrical power was off. Reset the correct time of day.
Investigate reason for power loss.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Check electrical |
|
|
| ||||
|
| TIMER |
|
|
|
| power to control |
|
|
| ||||
|
| DISPLAY |
|
|
|
| (outlet, transformer, |
|
|
| ||||
|
| BLANK. |
|
|
|
| power cable, all |
|
|
| ||||
|
|
|
|
|
|
| connections). |
|
|
| ||||
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
TIMER DISPLAY SHOWS |
|
|
|
|
|
|
|
| ||||||
|
|
|
| Do manual |
| |||||||||
CORRECT TIME AND DAY |
|
|
|
| ||||||||||
|
|
|
| |||||||||||
AND IS STEADY. |
|
|
|
| diagnostics. |
| ||||||||
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NO POWER POWER OK
REPAIR AS NEEDED
TIMER DEFECTIVE
Do manual diagnostics to verify proper function.