Maintenance: Clean the filters

CAUTION: Turn off the water to the shower, either at the main or with the service stops, before open- ing the valve.

Remove the handle and escutcheon.

Grasp the wrench flats on the cartridge stop unit with an adjustable wrench.

While holding the stop unit still, use a second ad- justable wrench or a 17mm deep socket wrench to unscrew and remove the thermostatic cartridge.

Failure to hold the stop unit steady while unscrewing or replacing the thermostat cartridge will result in damage to the stop unit.

Rinse any debris from the filters on the thermostatic cartridge. Use a soft toothbrush, if necessary.

Do not attempt to remove the screens.

Lubricate the o-rings with white plumbers grease. Reinstall the thermostatic cartridge in the stop unit.

Justify and reinstall the handle.

wrench flat stop unit

12

Image 12
Contents Installation Instructions / Warranty Service Isolation Stops Technical SpecificationsEnglish English Installation Considerations English Install the ThermoBalance II Rough Both outlets must be plumbed. Do not plug any portFlush the supply lines using the flushing plug Do not remove the installation boxThese instructions cover these models English Installation NotchTab Stop unit Justify the Handle This is the safety stop English User InstructionsEnglish Set the High Temperature Limit Stop optional Tools RequiredEnglish Maintenance Clean the filters Justify and reinstall the handle Wrench flat stop unitDo not attempt to remove the screens Français Données techniquesFrançais Prendre en considération pour l’installation Le robinet doit être de niveau sur tous les plans Le i-box doit demeurer sur la valve Ces jeux de garniture Scroll 06065XX0 06083XX0 06627000 Cross 06066XX0 06084XX0Français Installation CocheDispositif Réglez la poignée Fermez l’eauFrançais Instructions à l’intention de l’utilisateur Le bouton de contrôle de laFrançais Réglage de la butée limite d’eau chaude en option Entretien Nettoyage des tamis de filtreProblème Cause possible Solution DépannageOu remplacez la cartouche thermostatique Troubleshooting Problem Possible Cause SolutionReplacement Parts Cleaning Recommendation for Hansgrohe Products Recommandations pour le nettoyage des produits HansgroheLimited Lifetime Consumer Warranty Instructions de nettoyage pour robinetteries et douchesTo Obtain Warranty Parts or Information