Axor 06064XX0 installation instructions Justify the Handle

Page 9

Install the carrier plate gasket and carrier plate with the carrier plate screws.

Press the escutcheon very firmly over the carrier plate, so that the strips of Duotec interlock, produc- ing a very firm hold.

Install the handle: Tighten the handle screw, using a 3 mm Allen wrench. For proper operation of the valve, the handle screw must engage the slot milled into the brass on the cartridge.

Set the high temperature limit stop (optional) -- see page 11.

Justify the handle.

English

Justify the Handle

Tools required: Thermometer

3 mm Allen wrench (included with trim kit)

Turn the valve on. Place the thermometer in the water stream.

Turn the temperature control knob until the water coming out measures 100° on the thermometer.

Turn the water off using the lever part of the handle.

Use the 3 mm Allen wrench to loosen the set screw on the bottom of the handle. Remove the handle from the valve (1).

Hold the lever in one hand. With the other hand, turn the temperature control knob approximately

½turn clockwise (2a). Then, without pressing inward on it, turn it counter-clockwise until it is positioned vertically and hits the safety stop (2b).

Reinstall the handle and tighten the set screw (3).

2

ab

Image 9
Contents Installation Instructions / Warranty Service Isolation Stops Technical SpecificationsEnglish English Installation Considerations Both outlets must be plumbed. Do not plug any port English Install the ThermoBalance II RoughDo not remove the installation box Flush the supply lines using the flushing plugThese instructions cover these models English Installation NotchTab Stop unit Justify the Handle English User Instructions This is the safety stopTools Required English Set the High Temperature Limit Stop optionalEnglish Maintenance Clean the filters Justify and reinstall the handle Wrench flat stop unitDo not attempt to remove the screens Données techniques FrançaisFrançais Prendre en considération pour l’installation Le robinet doit être de niveau sur tous les plans Le i-box doit demeurer sur la valve Scroll 06065XX0 06083XX0 06627000 Cross 06066XX0 06084XX0 Ces jeux de garnitureCoche Français InstallationDispositif Fermez l’eau Réglez la poignéeLe bouton de contrôle de la Français Instructions à l’intention de l’utilisateurEntretien Nettoyage des tamis de filtre Français Réglage de la butée limite d’eau chaude en optionProblème Cause possible Solution DépannageOu remplacez la cartouche thermostatique Problem Possible Cause Solution TroubleshootingReplacement Parts Recommandations pour le nettoyage des produits Hansgrohe Cleaning Recommendation for Hansgrohe ProductsInstructions de nettoyage pour robinetteries et douches Limited Lifetime Consumer WarrantyTo Obtain Warranty Parts or Information