Mitsubishi Electronics MSH24WN Maintenance, When it is not going to be used for a long time

Page 11

WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME

MAINTENANCE

When it is not going to be used for a long time:

1Perform the FAN operation for 3 or 4 hours to dry the inside of the air conditioner.

To perform FAN operation, set the remote controller to the highest temperature in the MANUAL COOL mode. (Refer to page 8.)

” “Cool

Manual

operation

When the air conditioner is to be used again:

1Clean the air filter and install it in the in- door unit.

(Refer to page 12 for cleaning instructions.)

Clean the filter before installing.

Before starting maintenance

Turn off the breaker.

CAUTION

When the unit is to be cleaned, switch it off and turn off the breaker. Since the fan rotates at high speed during operation, it may cause an injury.

Cleaning the indoor unit

Clean the unit using a soft dry cloth.

Do not use gasoline, benzine, polishing powder, or in- secticide. The unit may be damaged.

2Turn off the breaker.

CAUTION

Turn off the breaker when the air conditioner is not going to be used for a long time.

Dirt may collect and this may cause a fire.

3Removetroller. the batteries from the remote con-

CAUTION

To prevent liquid leakage, take out all batteries when the remote controller is not going to be used for a long time.

2Check that the air inlet and outlet of the indoor/outdoor units are not blocked.

3Check that the ground is connected correctly.

CAUTION

Ground the unit.

Do not connect the ground to a gas pipe, water pipe, lightning rod or the ground of a telephone. If the ground- ing is incorrect, it may cause an electric shock.

CAUTION

Do not open the front panel up past the level position.

The panel may come off in order to prevent it from being damaged.

The front panel may also come off if the upper part of the front panel is pulled down.

Do not exceed.

Movable range

If the front panel comes off, attach it as explained below.

Keeping the front panel level with one hand, insert the hinges one by one with the other

 

hand into the notches at the left, right and center of the top of the indoor unit until they click

 

into place. (1) Then, close the front panel. (2)

 

1

 

Keep the front panel level and

 

 

 

 

 

 

 

 

insert the hinges into the notches.

2

Do not step onto an unstable bench when maintaining the unit, etc. This may cause an injury, etc. if you fall down.

11

Image 11
Contents English Español Operating Instructions Manual DE InstruccionesRepairs or relocation should not be done by the customer Safety PrecautionsCustomer should not install this unit Do not turn the breaker off/on during operationDo not use an insecticide or flammable spray Do not operate switches with wet handsDo not clean the air con- ditioner with water Ventilate well in using the unit with a stove, etcOutdoor unit Safety Precautions Name of Each PartDo not install the unit where flammable gas could leak Indoor unitOpen the front lid Remote controllerBreaker for the air conditioner Preparation Before OperationAuto restart function FEEL... Auto Operation Description of I FEEL... mode Manual Operation COOL, DRY, Heat To select the COOL, DRY or Heat modeRecommended Horizontal Vane range AIR Flow Velocity and Direction AdjustmentAuto air flow direction control operation To change the AIR Flow velocity, press the FAN buttonLong Operation Timer Operation ON/OFF Timer Before starting maintenance MaintenanceWhen it is not going to be used for a long time When the air conditioner is to be used againAir cleaning filter replacement about once every 4 months Cleaning the air filter about once every 2 weeksCleaning the deodorizing filter about once every 2 weeks Deodorizing filter replacement about once a yearAnswer not a malfunction When a power failure occursCheck the following QuestionQuestion Answer not a malfunction When YOU Think That Trouble has OccurredINSTALLATION, Relocation and Inspection Podría ser nocivo para su salud Medidas DE SeguridadEl cliente no debe reparar ni cambiar de sitio la unidad El cliente no debe instalar la unidadNo instale la unidad en un soporte roto No manipule los interrup- tores con las manos mo- jadasNo limpie el equipo de aire acondicionado con agua No utilice la unidad para fines que no sean los in- dicadosHaga una toma de tierra Medidas DE Seguridad Nombre DE LAS PartesUnidad interior Unidad exteriorAbra la tapa frontal Controlador remotoControlador remoto cómo colocar las pilas y ponerlo en hora Preparación Antes DE Ponerlo EN FuncionamientoFunción de reinicio automático Interruptor principal del acondicionador de aireDescripción del modo de accionamiento automático I Feel Accionamiento Automático I FeelNivel de humedad idóneo para las personas Para desactivarlos Pulse el botónPara cambiar la temperatura Para una refrigeración eficaz→ → → → Ángulo DE Giro → → Ajuste DE LA Velocidad Y DE LA Dirección DEL Flujo DE AireCómo ajustar automáticamente la dirección del flujo de aire Ángulo máximo del flujo de aire horizontalDurante el funciona Cómo configurar el temporizador de conexión Pulse el botónRealice los siguientes pasos mientras esté Pulse el botón LongOiga un clic Después cierre el panel frontal MantenimientoDesactive el interruptor Quite las pilas del controlador remotoColoque el filtro de aire Cómo sustituir el filtro desodorizante una vez al añoRetire el filtro de aire Retire el filtro de limpieza del aire Tipo fuelle blancoPregunta Compruebe lo siguienteConexion? ¿Es correcta la polari- dad +, de las pilas?SI Cree QUE SE HA Producido UN Problema INSTALACIÓN, Cambio DE Sitio Y Inspección Page Page SG79Y092H01