Mitsubishi Electronics PCH42GK, PCH24GK, PCH36GK, PCH30GK specifications OC277-63

Page 63

Part numbers that are circled are not shown in the illustration.

 

 

 

 

 

 

Q'ty / set

No.

Parts No.

Parts Name

Specifications

PCH

 

 

 

 

 

 

30, 36, 42GK

1

R01

35J

662

LEFT SIDE PANEL

 

1

2

T7W E00 666

SIDE PLATE-L.

 

1

3

T7W E01 676

REAR PANEL

 

1

4

R01

A15 500

FILTER

 

1

5

R01

17J

061

GRILLE HINGE

 

6

6

R01

18J

691

GRILLE ASSY

 

1

7

R01

17J

054

GRILLE CATCH

 

6

8

R01

17J

691

GRILLE ASSY

 

2

9

R01

A14 500

FILTER

 

2

10

R01

41J

669

UNDER PANEL

 

1

11

T7W E01 070

WIRELESS BOARD CASE

 

1

12

R01

35J

661

RIGHT SIDE PANEL

 

1

13

R01

17J

808

RIGHT LEG

 

1

14

T7W E01 668

SERVICE PANEL

 

1

15

R01

35J

067

RIGHT SIDE BOX

 

1

16

T7W E00 665

SIDE PLATE-R.

 

1

17

T7W E01 651

FRONT PANEL

 

1

18

R01

41J

002

AUTO VANE

 

1

19

R01

41J

085

GUIDE VANE ASSY-5R.

 

1

20

R01

43J

087

GUIDE VANE ASSY-5C.

 

2

21

R01

42J

086

GUIDE VANE ASSY-5L.

 

1

22

T7W 051 501

AIR FILTER

 

1

23

R01

35J

223

VANE MOTOR

 

1

24

R01

17J

809

LEFT LEG

 

1

25

R01

17J

523

JOINT SOCKET

 

1

26

T7W E00 072

DRAIN HOSE COVER

 

1

 

 

 

 

 

 

 

Remarks

Wiring

Recom-

Price

 

(Drawing No.)

Diagram mended

Unit Amount

Symbol

Q'ty

MV

OC277-63

Image 63
Contents OC277-1 ContentsOC277-2 FeaturesEasy Maintenance no Maintenance Necessary for 2500 Hours OC277-3Improving Efficiency of Piping Work OC277-4 Part Names and FunctionsOC277-5 Remote controller operation buttonsOC277-6 Remote controller displaySpecifications OC277-7Models PCH24GK, PCH30GK, PCH36GK, PCH42GK CFM SHC TPC DataOC277-8 Models PCH24GK, PCH30GK, PCH36GK, PCH42GK Performance DataCFM OC277-9Performance Curve OC277-10PCH36GK Cooling Capacity PCH36GK Heating Capacity OC277-11Condensing Pressure and Suction Pressure OC277-12PCH30GK OC277-13PCH36GK OC277-14PCH42GK OC277-15OC277-16 Standard Operation DataSHF PCH24GK PCH30GK PCH36GK PCH42GK Additional Refrigerant Charge R22oz OC277-17Operating Range Outlet AIR Speed and Coverage RangePCH36GK PCH42GK OC277-18Noise Criterion Curves PCH24GK PCH30GKOutlines and Dimensions OC277-19Indoor unit PCH24GK Indoor unit PCH30/36/42GK OC277-20PCH30GK PCH36GK PCH42GK Refrigerant System DiagramRemote controller OC277-21Wiring Diagram Model PCH24/30/36/42GK Wiring DiagramOC277-22 Operation FLOW-CHART OC277-23Main Operation Cooling Operation OC277-24YES OC277-25DRY Operation DRYHeating Operation OC277-26Microprocessor Control OC277-27Outline of Microprocessor Control Compressor control How to operateOC277-28 Indoor Unit ControlTermination conditions OC277-29Start condition Coil frost protectionAuto Return OC277-30Auto vane control SwingOC277-31 Detecting abnormalities in the outdoor unitRange a Range B Range C DRY operation time chart How to operate OC277-32DRY operation OC277-33 Display in Heat operation Heat operation time chartOC277-34 Heat operationOverheat prevention OC277-35Overheat protection Booster heater controlIndoor coil temperature abnormality detection OC277-36Defrosting operation OC277-37 Initial mode How to operateMode change Temperature rangeOC277-38 COOL/DRY operationAuto return Test run Before test run Timer operationTimer function OC277-39OC277-40 Emergency operationBefore emergency operation On indoor controller board Dip switch functionsOn remote controller board OC277-41PCH36, 42GK Fan motor max. rotational frequency Service RefOC277-42 PCH24GK PCH30GK PCH36GK PCH42GK SW7 OFFTrouble Shooting Remote Controller Display AbnormalityOC277-43 Example Check Unit code address When malfunction occurs during operationFor group control using one remote controller OC277-44OC277-45 Heat Wrong Wiring on SiteOC277-46 CoolOther Troubles and Causes OC277-47How to check the parts OC277-48PCH OC277-49 PAC-SA89TA-E System ControlOC277-50 Variety of System Control FunctionsOC277-51 Group Control with a Single Remote ControllerHow to wire How to set unit-addressRemote controller LCD indication Control Using TWO Remote ControllersRemote ON-OFF and Individual Remote Controls How to set SW17-7 See FigureOC277-53 Individual Control by Grouping the Remote ControllersBasic wiring Switch function of remote ON-OFF switchAuto Restart Function Multiple Remote Control DisplayTimer Operation or the Operation by AN External Signal OC277-54Removing the air intake grille Disassembly ProcedurePCH24GK Operating Procedure OC277-55Removing the side panel OC277-56Removing the fan motor Removing the sirocco fanRemoving the Indoor coil thermistor Operating Procedure PhotosOC277-57 Removing the vane motorRemove the intake grille OC277-58Removing the drain pan Removing the guide vaneOC277-59 Removing the support heaterRemoving the heat exchanger Parts List OC277-60Structural Part PCH24GK OC277-61 Structural Part PCH30GK PCH36GK PCH42GK OC277-62OC277-63 FAN and Heater Parts PCH24GK OC277-64FAN and Heater Parts PCH30GK PCH36GK PCH42GK OC277-65Electrical Parts PCH24GK10 PCH30GK PCH36GK PCH42GK OC277-66Timer Optional PartsOC277-67 SET Back Display PAC-SC32PTA Weekly Timer Setting DisplayOC277-68 Names and functionsRefrigerant Pipes Timer AdapterMultiple Remote Controller Adapter OC277-69Specifications are subject to change without notice