Electro-Voice EVF-1122S Inner Connection Points, Left-to-Right Horizontal Cluster Angles

Page 50

6.0 Rigging-Strength Ratings and Safety Factors (cont’)

6.54 Inner Connection Points

For connection between the clusters (from bottom of top enclosure to the top of the bottom enclosure), both the front and rear rigging plates must be connected (see Figure 34). The maximum box-to-box angle is 45°.

When Rigging Box-to-Box, both front and rear tie plates must be connected.

Figure 34:

Box-to-Box internal connection points of a

horizontal cluster using HRK horizontal rigging kits

6.55 Left-to-Right Horizontal Cluster Angles

The suspended horizontal cluster must be perpendicular (plumb) to within ±5° as shown in Figure 35.

Figure 35:

Left-to-right angle limits for a horizontal cluster (angle shown exaggerated for illustration purposes)

50

Electro-Voice EVF/EVH User Manual

Image 50 Contents
Page Table of Contents Table of Contents cont’ Rigging-Safety WarningIntroduction Introduction cont’ EVF-1122S/96 exampleEnd View Front View Side View 143.0 lb 64.9 kg 145.5 lb 66.1 kg Key suspension point dimensions as shown in figure above DimensionEVH Horn-Loaded Series Finishes and Colors AvailableEVF Front-Loaded Series Accessories for EVF and EVH Systems Tool ListDirectivity Break Frequency Defined General Aiming and Placement GuidelinesDesigning an EVF/EVH Cluster Designing an EVF/EVH Cluster cont’ Basic Clustering GuidelinesCoverage-Uniformity Target Multiple-Source Interference in Clusters Normalized See text for more detailsReducing Multiple-Source Interference EVF Full-Range Designing an EVF/EVH Cluster cont’ Passive/Biamp Crossover Configuration Preparing EVF and EVH Systems for InstallationRecommended Preflight Procedures Preparing EVF and EVH Systems for Installation cont’ Rotation of High-Frequency Waveguides EVF systemsDigital Signal Processing Full-Range Systems in Passive Mode Preparing EVF and EVH Systems for Installation cont’ VRK-1 or HRK-1 connection VRK-2 or HRK-2 connection EVF and EVH Rigging SystemIntroduction Flying EV-Innovation EV-I Loudspeaker System VRK-1 or HRK-1 connectionVRK-2 rigging kit with parts identified EVF and EVH Rigging System cont’VRK-1 rigging kit with parts identified VRK-3 rigging kit with parts identifiedHRK-3 rigging kit with parts identified HRK-1 rigging kit with parts identifiedHRK-2 rigging kit with parts identified Important Details that Apply to the VRK and HRK Rigging Kits EV-I Rigging PrimerEVF and EVH Rigging System cont’ Eyebolt Installation Hardware not shown, using a All-Eyebolt ClustersTwo-system horizontal cluster using VRK Kits and Vertically Rigged Clusters Systems, using a moderate trim angleSystems, using an extreme trim angle HRK Kits and Horizontally Rigged Clusters EVF Full-Range Six-enclosure horizontal hang of three systems above Assembly Instructions for VRK and HRK kits Short in front Toward grille Rigging-Strength Ratings and Safety Factors Working Load Limit and Safety-Factor DefinitionsRigging-Strength Ratings and Safety Factors cont’ Structural Rating OverviewLimits for ALL-EYEBOLT Clusters only All-Eyebolt Structural RatingsWorking Load Limits for Eyebolts WLL for M10 eyebolts in the EVI-M10K eyebolt kitSuspension-Line Angles Left-to-Right All-Eyebolt Cluster AnglesVRK Rigging Structural Ratings for Vertical Clusters Limits for Vertical Clusters only WLL for M10 eyebolts in the EVI-M10K eyebolt kit Left-to-Right Vertical Cluster Angles HRK Rigging Structural Ratings for Horizontal Clusters Maximum load and maximum height for horizontal clustersUsing Tie Plates as Main Load-Bearing Suspension Two cluster using HRK rigging kitsSuspension-Line Angles for HRK Kits Symmetry for Horizontal Clusters using HRK Kits Inner Connection Points Left-to-Right Horizontal Cluster AnglesElectro-Voice Structural-Analysis Procedures Ratings for Outdoor Applications with Wind LoadingRigging Inspections and Precautions Mechanical Engineering printed ReferencesRigging printed Rigging Web sitesPage Page Electro-Voice
Related manuals