Electro-Voice EVF-1152D, EVF-2121S, EVH-1152S, EVF-1122D Assembly Instructions for VRK and HRK kits

Page 35

5.0 EVF and EVH Rigging System (cont’)

5.24 Assembly Instructions for VRK and HRK kits

Both the VRK and HRK rigging kits share the same mounting hole positions and letter designations. Tables 5, 6, and 7 apply to both the VRK and HRK kits. The only difference between the kits is the HRK rigging plates have an integral tie plate and the VRK kits use a stabilizing bar.

1.Refer to Tables 5, 6, or 7 to determine which lettered hole position to use. Follow the direc- tions in these tables for arrow direction and positioning on the cabinet. Note that “Front” will always refer to the front of the enclosure (i.e., the grille).

2.HRK kits skip to step 3. For VRK kits, preassemble them using the supplied hardware by attaching the stabilizer bar to both the large and small rigging plates. Attach the stabilizer bars to the back side of the plates, using a #2 Phillips screwdriver, the eight M5 pan-head machine screws and M5 split-lock washers supplied with the hardware kit. You are now ready to attach the VRK kits to the loudspeakers.

3.Referring to Tables 5, 6 or 7 (depending on which systems are being connected), find which rigging-plate letter will give you the desired angle. Also pay attention to the arrow direction as listed in the table.

4.

With a 6-mm Allen (hex) wrench, remove the M10 flathead bolts that were installed by the

 

factory. Remove only those bolts that are going to be replaced by rigging hardware, in order

 

to remain safe and avoid audible enclosure leaks.

5.Using the appropriately lettered rigging-plate holes, attach the VRK or HRK kits to the en- closure sides using the eight supplied M10 button-head bolts and split-lock washers. Use a 6-mm Allen (hex) wrench.

6.Install any M10 eyebolts that are needed for suspension, pull back, or stabilization at this time.

7.

Ensure that all M10 bolt points in the enclosure have an M10 flathead bolt, an M10 eyebolt

 

or an M10 button-head bolt where the rigging plates attach. Do not hang any cluster with

 

missing M10 bolts!

8.Check all M10 and M5 fasteners and eyebolts to ensure they are tight.

9.You are now ready to hoist the cluster and make the final attachments to the building struc- ture.

Electro-Voice EVF/EVH User Manual

35

Image 35 Contents
Page Table of Contents Rigging-Safety Warning Table of Contents cont’Introduction EVF-1122S/96 example Introduction cont’End View Front View Side View 143.0 lb 64.9 kg 145.5 lb 66.1 kg Dimension Key suspension point dimensions as shown in figure aboveEVH Horn-Loaded Series Finishes and Colors AvailableEVF Front-Loaded Series Tool List Accessories for EVF and EVH SystemsDirectivity Break Frequency Defined General Aiming and Placement GuidelinesDesigning an EVF/EVH Cluster Basic Clustering Guidelines Designing an EVF/EVH Cluster cont’Coverage-Uniformity Target Multiple-Source Interference in Clusters See text for more details NormalizedReducing Multiple-Source Interference EVF Full-Range Designing an EVF/EVH Cluster cont’ Passive/Biamp Crossover Configuration Preparing EVF and EVH Systems for InstallationRecommended Preflight Procedures Rotation of High-Frequency Waveguides EVF systems Preparing EVF and EVH Systems for Installation cont’Digital Signal Processing Full-Range Systems in Passive Mode Preparing EVF and EVH Systems for Installation cont’ VRK-1 or HRK-1 connection EVF and EVH Rigging SystemIntroduction Flying EV-Innovation EV-I Loudspeaker System VRK-1 or HRK-1 connection VRK-2 or HRK-2 connectionVRK-3 rigging kit with parts identified EVF and EVH Rigging System cont’VRK-1 rigging kit with parts identified VRK-2 rigging kit with parts identifiedHRK-3 rigging kit with parts identified HRK-1 rigging kit with parts identifiedHRK-2 rigging kit with parts identified EV-I Rigging Primer Important Details that Apply to the VRK and HRK Rigging KitsEVF and EVH Rigging System cont’ Eyebolt Installation All-Eyebolt Clusters Hardware not shown, using aTwo-system horizontal cluster using VRK Kits and Vertically Rigged Clusters Systems, using a moderate trim angleSystems, using an extreme trim angle HRK Kits and Horizontally Rigged Clusters EVF Full-Range Six-enclosure horizontal hang of three systems above Assembly Instructions for VRK and HRK kits Short in front Toward grille Working Load Limit and Safety-Factor Definitions Rigging-Strength Ratings and Safety FactorsStructural Rating Overview Rigging-Strength Ratings and Safety Factors cont’All-Eyebolt Structural Ratings Limits for ALL-EYEBOLT Clusters onlyWLL for M10 eyebolts in the EVI-M10K eyebolt kit Working Load Limits for EyeboltsLeft-to-Right All-Eyebolt Cluster Angles Suspension-Line AnglesVRK Rigging Structural Ratings for Vertical Clusters Limits for Vertical Clusters only WLL for M10 eyebolts in the EVI-M10K eyebolt kit Left-to-Right Vertical Cluster Angles Maximum load and maximum height for horizontal clusters HRK Rigging Structural Ratings for Horizontal ClustersTwo cluster using HRK rigging kits Using Tie Plates as Main Load-Bearing SuspensionSuspension-Line Angles for HRK Kits Symmetry for Horizontal Clusters using HRK Kits Left-to-Right Horizontal Cluster Angles Inner Connection PointsRatings for Outdoor Applications with Wind Loading Electro-Voice Structural-Analysis ProceduresRigging Inspections and Precautions Rigging Web sites ReferencesRigging printed Mechanical Engineering printedPage Page Electro-Voice
Related manuals
Manual 2 pages 29.71 Kb