Electrical Connection
This appliance must be earthed.
The manufacturer declines any responsibil ity should this safety measure not be ob served.
Before switching on make sure the electricity supply voltage is the same as that indicated on the appliance rating plate.
Changing a fuse
Your appliance is supplied with a 13 amp plug fitted. In the event of having to change the fuse in the plug supplied, a 13amp ASTA approved (BS1363A) fuse must be used,
Should the plug need to be replaced for any reason, proceed as described below.
The wires on the mains lead are coloured in accordance with the following code.
Green and Yellow | |
Blue | |
Brown |
The wired coloured green and yellow must be connec ted to the terminal marked with the letter "E" or by the
earth symbol or coloured green and yellow.
The wired coloured blue must be connected to the ter minal "N" or coloured black.
The wire cooured brown must be connected to the ter minal marked "L" or coloured red.
Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over the outer sheath.
A cut off plug inserted into a 13amp socket is a serious safety (shock) hazard.
Ensure that the cut of plug is disposed of sa fely.
Permanent connection
In the case of permanent connection it is necessary that you install a double pole switch between the ap pliance and the electricity supply (mains), with a mini mum gap of 3mm between the switch contacts and a type suitable for the required load in compliance with the current electrical regulations.
The switch must not break the yellow and green earth cable at any point.
AEG | 153 0409 20 / 09.99 |