Electrolux DFKTWC75GS installation instructions Operation, Controls

Page 16

16Operation

Controls

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

light

filter

fan

fan speed

delay display

 

switch

reset

on/off

switches

shut

 

 

 

switch

switches

 

off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dead-front mode

Stand-by mode

In dead-front mode, press any key for enter in stand- by mode.

If the hood is in stand-by mode, after 10 seconds on return automatically in dead-front mode.

Light switch

Press any key for enter in stand-by mode.

Push the light switch once to turn the lights ON to a dim level.

Push a second time to turn the lights ON to a brighter level.

Push a third time to turn the lights OFF (stand-by mode).

Fan speed switches

Press any key for enter in stand-by mode. The fan speed switches turns the fan on. 1 : fan ON at low speed

2 : fan ON at medium-low speed

3 : fan ON at medium-high speed

4 : fan ON at high speed

Fan on/off switch

Push this fan switch to turn OFF the fan. The hood turns in the stand-by mode.

Delay shut off switch

Pressing this switch when is active any speed, sets a timer which keeps the fan operating at this speed for 10 minutes (the number “10” appears in the display). After 10 minutes, the hood turns in the stand-by mode.

Push this switch once to turn the timer Off.

Filter reset switch

When the filter switch is illuminated, it is necessary to clean the GREASE FILTERS. Once the grease filters are cleaned and installed, press in and hold the “filter reset switch” for approximately 3 seconds.

When the filter switch is illuminated and blink, it is necessary to replace the CHARCOAL FILTER. Once the new charcoal filter is installed, press in and hold the “filter reset switch” for approximately 3 seconds.

Heat Sentry

Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a device that will turn on or speed up the blower if it senses excessive heat above the cooking surface.

1)If blower is OFF - it turns blower ON to HIGH speed.

2)If blower is ON at a lower speed setting - it turns blower up to HIGH speed.

When the Heat Sentry is active, the word “HS” appears in the display and the tone alarm is active. To disarm the tone alarm, press the 4 fan speed switch.

When the temperature level drops to normal, the blower will return to its original setting.

IMPORTANT

The HEAT SENTRY thermostat can start the blower even if the hood is turned OFF. When this occurs, it is impossible to turn the blower OFF with its switch. If you must stop the blower, do it from the integral disconnecting switch located inside the blower housing.

Heat Sentry active

Image 16
Contents Use & Care Guide Installation Instructions Page Table of contents Finding InformationPlease read and save this guide Keep a record for quick referenceSafety Important Safety InstructionsIntegral Disconnecting Switch Verify package contents Install the ductwork InstallationTo reduce the risk of fire, use only metal ductwork 33-7/16 WiringImproper grounding can result in a risk of electric shock Install mounting bracket Install flue mounting bracket DUCTEDANDNON-DUCTEDPrepare the hood Ducted CONFIGURATIONNON- Ducted Configuration Install the hood At least two people will be required to mount the hoodRooms with 10-FOOT Ceilings Install filters Ducted and NON-DUCTED HoodsPrior to use, remove protective film from the filter frame NON-DUCTED Hoods onlyGrease filters Hood cleaning MaintenanceNon-Ducted Recirculation filters Operation ControlsHalogen bulbs Fuse replacement Switch OFF the Electricity SupplyWarranty Information WarrantyPage 04307838/3S