Electrolux 20604 G - 21604 Burner, Auxiliary28 Semi-rapid32 Rapid40 Aeration adjustment none

Page 12

 

BURNER

 

RAPID

SEMI-RAPID

AUXILIARY

TYPE OF GAS

 

 

(large)

(medium)

(small)

 

 

 

 

 

 

 

 

 

POSITION

 

M A X

MIN

M A X

MIN

M A X

MIN

 

NOMINAL THERMAL

 

 

 

 

 

 

NATURAL GAS

POWER

kW

3.0

0.65

2.0

0.45

1.0

0.33

20 mbar

NOMINAL FLOW

 

 

 

 

 

 

 

VALUE =

RATE

m3/h

0.286

0.057

0.190

0.038

0.095

0.028

37.78 MJ/m3

NOZZLE REFERENCE

119

Adjust.

96

Adjust.

70

Adjust.

Ws - 50.7 MJ/ m3

 

1/100 mm

 

 

 

 

 

 

 

 

NOMINAL THERMAL

 

 

 

 

 

 

LPG GAS

POWER

kW

2.8

0.65

2.0

0.45

1.0

0.33

28-30/37 mbar

NOMINAL FLOW

 

 

 

 

 

 

 

VALUE =

 

 

 

 

 

 

 

RATE

g/h

202

43.5

144

29

72

21,5

49.92 MJ/Kg

 

 

 

 

 

 

 

 

 

NOZZLE REFERENCE

86

40

71

32

50

28

 

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner

Dia. Tap By-pass

 

1/100 mm

Auxiliary28

Semi-rapid32

Rapid40

Aeration adjustment none

46

Image 12
Contents Gebruiksaanwijzing en Installatievoorschrift 21604 G 21602 GImportant Safety Information InstallationChild Safety During UseService Environmental Information73/23 EEC 90/683 EEC 93/68 EEC 89/336 EEC 90/396 EEC Contents Description of the Hobs Mod GOperation DiameterMaintenance and Cleaning Hob TopPan Supports BurnersElectrical supply is switched on Something Not Working?Check that the Rccb has not tripped Check the mains fuse has not blownService and Spare Parts 0870 5 929Calls to this number may be recorded for training purposes Guarantee Conditions Standard guarantee conditionsEuropean Guarantee This guarantee does not coverInstructions for the Installer Engineer technical dataAuxiliary28 Semi-rapid32 Rapid40 Aeration adjustment none BurnerImportant safety requirements LocationInstallation Gas Connection Cut Out Size BuildingBuilding over a cupboard or drawer Building over a kitchen unit with door Fitting the hob to the worktop Sealing gasket supplied withCabinet below Place the sealing gasket Cut outEarth symbol or coloured green and yellow Electrical connectionsBrown Live Wiring diagram Permanent ConnectionFault Finding Preliminary Electrical Systems CheckEarth Continuity Check Ignition System / Gas Ignition Check gas supply at burnerPressure Testing CommissioningRemove the control knob Conversion from Natural Gas to LPG MethodAEG Hausgeräte GmbH Postfach 90327 Nürnberg Electrolux plc 02/03