Commissioning

When the hob has been fully installed it will be necessary to check the minimum flame setting. To do this, follow the procedure below.

Φ1) Turn the gas tap to the MAX position and ignite.

2)Set the gas tap to the MIN flame position then turn the control knob from MIN to MAX several times. If the flame is unstable or is extinguished follow the procedure below.

Procedure:

Φ1) ReMIN-ignite.the burner and set to

2)Remove the control knob.

3)You can find two different adjustment screw locations according to the gas tap (see diagram). The "b" type has the adjustment screw located down the centre of th egas tap control shaft. The "c" type has the by pass screw located to the side of the gas tap itself.

FO 1032

a)Minimum adjustment screw

b)Tap

To adjust, use a thin bladed

screwdriver and turn the adjustment screw until the flame is steady and does not extinguish, when the knob is turned from MIN to MAX. Repeat this procedure for all burners.

Pressure Testing

Φ1) Remove left hand pan support and front left burner cap and crown.

2)Fit manometer tube over the injector.

3)Turn on the burner gas supply and ignite another burner supply.

The pressure reading should be nominally 20mbar and must be between 17 mbar and 25mbar.

4)Turn off the burner supplies.

58

Image 24
Contents Gebruiksaanwijzing en Installatievoorschrift 21604 G 21602 GImportant Safety Information InstallationChild Safety During UseService Environmental Information73/23 EEC 90/683 EEC 93/68 EEC 89/336 EEC 90/396 EEC Contents Description of the Hobs Mod GOperation DiameterMaintenance and Cleaning Hob TopPan Supports BurnersElectrical supply is switched on Something Not Working?Check that the Rccb has not tripped Check the mains fuse has not blownService and Spare Parts 0870 5 929Calls to this number may be recorded for training purposes Guarantee Conditions Standard guarantee conditionsEuropean Guarantee This guarantee does not coverInstructions for the Installer Engineer technical dataAuxiliary28 Semi-rapid32 Rapid40 Aeration adjustment none BurnerImportant safety requirements LocationInstallation Gas Connection Cut Out Size BuildingBuilding over a cupboard or drawer Building over a kitchen unit with door Fitting the hob to the worktop Sealing gasket supplied withCabinet below Place the sealing gasket Cut outEarth symbol or coloured green and yellow Electrical connectionsBrown Live Wiring diagram Permanent ConnectionFault Finding Preliminary Electrical Systems CheckEarth Continuity Check Ignition System / Gas Ignition Check gas supply at burnerPressure Testing CommissioningRemove the control knob Conversion from Natural Gas to LPG MethodAEG Hausgeräte GmbH Postfach 90327 Nürnberg Electrolux plc 02/03