Electrolux G-11602, G-21602, 20604 G - 21604 Important safety requirements, Location

Page 13

Important safety requirements

This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition).

Detailed recommendations are contained in the following British Standards Codes Of Practice: B.S. 6172/ B.S. 5440, Par. 2 and B.S. 6891 Current Editions.

The hob should not be installed in a bed sitting room with a volume of less than 20 m3. If it is installed in a room of volume less than 5 m3 an air vent of effective area of 110 cm2 is required. If it is installed in a room of volume between 5 m3 and 10 m3 an air vent of effective area of 50 cm2 is required, while if the volume exceeds 11 m3 no air vent is required.

However, if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3.

If there are other fuel burning appliances in the same room, B.S. 5440 Part 2 Current Edition, should be consulted to determine the requisite air vent requirements.

Location

The hob may be located in a kitchen, a kitchen/diner or bed sitting room, but not in a bathroom or shower room.

Before making the cut out in the worktop ensure that there is a minimum distance of 55 mm. between the rear edge of the hob and the wall.

A minimum distance of 100 mm. must be left between the side edges of the hob and any adjacent cabinets or walls.

The minimum distance combustible material can be fitted above the hob in line with the edges of the hob is 420 mm. If it is fitted below 420 mm. a space of 50 mm. must be allowed from the edges of the hob.

The minimum distance combustible material can be fitted directly above the hob is 700 mm.

47

Image 13
Contents 21604 G 21602 G Gebruiksaanwijzing en InstallatievoorschriftInstallation Important Safety InformationChild Safety During UseEnvironmental Information Service73/23 EEC 90/683 EEC 93/68 EEC 89/336 EEC 90/396 EEC Contents Mod G Description of the HobsDiameter OperationHob Top Maintenance and CleaningPan Supports BurnersSomething Not Working? Electrical supply is switched onCheck that the Rccb has not tripped Check the mains fuse has not blown0870 5 929 Service and Spare PartsCalls to this number may be recorded for training purposes Standard guarantee conditions Guarantee ConditionsEuropean Guarantee This guarantee does not coverEngineer technical data Instructions for the InstallerBurner Auxiliary28 Semi-rapid32 Rapid40 Aeration adjustment noneLocation Important safety requirementsInstallation Gas Connection Building Cut Out SizeBuilding over a cupboard or drawer Building over a kitchen unit with door Sealing gasket supplied with Fitting the hob to the worktopCabinet below Place the sealing gasket Cut outElectrical connections Earth symbol or coloured green and yellowBrown Live Permanent Connection Wiring diagramPreliminary Electrical Systems Check Fault FindingEarth Continuity Check Check gas supply at burner Ignition System / Gas IgnitionCommissioning Pressure TestingRemove the control knob Method Conversion from Natural Gas to LPG02/03 AEG Hausgeräte GmbH Postfach 90327 Nürnberg Electrolux plc