| S I G | 4 0 0 |
|
|
|
TECHNICAL DATA |
|
|
|
| |
DIMENSIONS |
|
|
|
|
|
| Height |
| Width | Depth | |
Height to hotplate | 900mm (nominal) | 550mm (nominal) | 600mm | ||
|
|
|
|
| (to front of |
|
|
|
|
| door panel) |
Space for fixing at hotplate level | 2mm minimum clearance |
|
|
| |
Space for fixing above hotplate level | |||||
Minimum space above hotplate | 787mm (If a cooker hood is fitted refer to the cooker hood | ||||
| installation instructions). |
|
|
| |
Weight of appliance | 60.5kg. |
|
|
|
|
Minimum distance from rear wall | 5mm (spacer given by pressed spacer on vent panel). | ||||
CONNECTIONS |
|
|
|
|
|
Gas | Rear left hand side of cooker at | hotplate level. |
| ||
| Rc½ (½" B.S.P. female). |
|
|
| |
Electric | 220V/240V 50 Hz mains 3 core cable is supplied with an integral, | ||||
| moulded plug fitted with a 3 amp fuse. |
| |||
IGNITION |
|
|
|
|
|
Spark generator | APCO 6+1 MG 7424/1 |
|
|
| |
GRILL | Natural Gas |
|
| L.P.Gas |
|
Heat Input | 3.3kW (11263 Btu/h) |
| 3.0kW (215 g/h) |
| |
Injector Marking | 138 |
|
| 088 |
|
HOTPLATE |
|
| Natural Gas |
| |
| R.H.F. | R.H.R. |
| L.H.R. | L.H.F |
Heat Input | 1.0kW | 2.0kW |
| 2.0kW | 2.8kW |
| (3412 Btu/h) | (6824 Btu/h) | (6824 Btu/h) | (9554 Btu/h) | |
Injector Marking | 079 | 104 |
| 104 | 130 |
|
| L.P.Gas |
| ||
| R.H.F. | R.H.R. |
| L.H.R. | L.H.F. |
Heat Input | 1.0kW | 2.0kW |
| 2.0kW | 2.7kW |
| (71.85 g/h) | (143.7 g/h) | (143.7 g/h) | (194 g/h) | |
Injector Marking | 051 | 072 |
| 072 | 083 |
41