Emerson 1700, 2700 Wiring for 9-wire remote installations, Core processor on transmitter

Page 26

Wiring the Transmitter to the Sensor

3.4Wiring for 9-wire remote installations

If you chose a 9-wire remote installation (see Figure 2-1), a 9-wire cable must be used to connect the junction box on the sensor to the core processor on the transmitter/core processor assembly.

CAUTION

Allowing the shield drain wires to contact the sensor junction box can cause flowmeter errors.

Do not allow the shield drain wires to contact the sensor junction box.

To connect the cable, follow the steps below:

1.Refer to Micro Motion’s 9-Wire Flowmeter Cable Preparation and Installation Guide for instructions on cable shielding and preparation:

At the sensor end, follow the instructions for your cable type.

At the transmitter end, follow the instructions for your cable type with an MVD transmitter.

2.To connect the wires, refer to Micro Motion’s 9-Wire Flowmeter Cable Preparation and Installation Guide and follow the instructions for your sensor with an MVD transmitter. Additional information for connecting the wires at the transmitter is provided below:

a.Identify the components shown in Figure 2-6.

b.Remove the end-cap.

c.Insert the 9-wire cable through the conduit opening.

d.Connect the wires to the plugs supplied with the transmitter.

e.Insert the plugs into the sockets inside the lower conduit ring. See Figure 3-4.

Figure 3-49-wire cable between sensor and core processor (on transmitter)

9-wire cable from sensor

Black

(Drains from all wire sets)

Core processor (on transmitter)

Ground screw

Black

Brown

Red

Green

White

Blue

Gray

Orange

Violet

Yellow

Brown

Red

Violet

Green

Yellow

White

 

Plug and socket

Blue

Gray

Orange

Mounting screw

3. Ground the cable.

22

Micro Motion® Model 1700 and 2700 Transmitters

Image 26
Contents Micro Motion Model 1700 Model 2700 Transmitters Page Contents Index Overview SafetyBefore You Begin Flowmeter components Transmitter installation procedures Flowmeter documentation 1Flowmeter documentation resourcesMicro Motion customer service Installing the Transmitter Installation architecture1Installation types AC power requirements Temperature limitsPower source Determining an appropriate locationDC power requirements 1Typical power cable resistances at 68 F 20 C2Maximum cable lengths Accessibility for maintenanceMaximum cable lengths Mounting the transmitterIntegral installations 2Rotating the transmitter34-wire remote Wall mount or pipe mount 3 9-wire remote installations 59-wire remote Wall mount or pipe mount6Transmitter/core processor assembly Exploded view Mounting the remote core processor7Remote core processor Wall mount or pipe mount Grounding the flowmeter components 3Grounding methods for flowmeter componentsSupplying power Rotating the displayInstalling the Transmitter 10Display components Wiring the Transmitter to the Sensor Cable typesWiring for 4-wire remote installations 1 4-wire cable2 9-wire cable 3Wiring to the mating connector Wiring for 9-wire remote installations Core processor on transmitterSubtask 1 Wire the remote core processor to the transmitter 5Cable glands 7Wrapping the shield drain wires 10Gland body and core processor housing Subtask 2 Wiring the sensor to the remote core processor 129-wire cable between sensor and core processorWiring the Transmitter to the Sensor Output terminals and output types Output Wiring Model 1700/2700 Analog TransmittersOutput wiring 1Terminals and output types1Basic analog wiring 2HART/analog single-loop wiring Smart Family Output Wiring Intrinsically Safe Safe area output wiring Safe area mA output wiring2Safe area mA output load resistance values Safe area frequency/discrete output wiring 5Safe area frequency/discrete output wiringHazardous area output wiring Hazardous area safety parametersHazardous area current 2Safety parametersHazardous area voltage Hazardous area capacitanceHazardous area mA output wiring Hazardous area frequency/discrete output wiringHazardous area Output Wiring Model 2700 Configurable I/O Transmitters Channel configuration1Channel configuration MA output wiring2Basic mA wiring Frequency output wiring 5Frequency output Terminals 3 & 4 Channel B Internal power 7Frequency output Terminals 5 & 6 Channel C Internal power Discrete output wiring 9Discrete output 1 Terminals 3 & 4 Channel B Internal power11Discrete output 2 Terminals 5 & 6 Channel C Internal power Volts Voltage Output Level High Discrete input wiring 2Input voltage ranges for external power16Discrete input Terminals 5 & 6 Channel C Internal power Micro Motion Model 1700 and 2700 Transmitters Foundation fieldbus wiring 1Connecting the fieldbus communication wiresPROFIBUS-PA wiring 2Connecting the PROFIBUS-PA communication wiresPower connection SpecificationsFunctional specifications Service port connectionFisco and Fnico approval Input/output signals Input signal from sensorCore processor connection Specifications Operating Absolute minimum = 100 Ohms for V supply 25.6 volts Specifications HART/Bell202 Service portDigital communication Foundation fieldbus or PROFIBUS-PA transmittersAmbient temperature effect Power supplyEnvironmental requirements Ambient temperature limits EMC complianceOutputs UL and CSATransmitter Atex and IECExHousing Performance specificationsPhysical specifications MountingInterface/display WeightDimensions Dimensions in inchesmm Inches Dimensions in mm Or M20 × 11/16 160 13/16 139 ″-14 NPT 158 182 × Ø3/8 13/16 148 15/16 × 1/2″-14 NPT Figure A-5Dimensions Remote core processor Index AtexRemote core processor with remote Index Micro Motion Model 1700 and 2700 Transmitters Page 20001700