Output Wiring – Model 1700/2700 Intrinsically Safe Transmitters
Figure 5-2 Safe area mA output load resistance values
Rmax = (Vsupply – 12)/0.023
If communicating with HART, a minimum of 250 Ω and 17.5 V is required
| 1000 |
|
|
|
|
|
|
|
|
|
| 900 |
|
|
|
|
|
|
|
|
|
| 800 |
|
|
|
|
|
|
|
|
|
(Ohms) | 700 |
|
|
|
|
|
|
|
|
|
600 |
|
|
|
|
|
|
|
|
| |
load |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
R | 500 |
|
|
|
|
|
|
|
|
|
resistor |
|
|
|
|
|
|
|
|
| |
400 |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
External | 300 |
|
|
|
| OPERATING REGION |
|
| ||
|
|
|
|
|
|
| ||||
200 |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
| 100 |
|
|
|
|
|
|
|
|
|
| 0 |
|
|
|
|
|
|
|
|
|
| 12 | 14 | 16 | 18 | 20 | 22 | 24 | 26 | 28 | 30 |
Supply voltage VDC (Volts)
Figure 5-3 Safe area HART/analog single-loop wiring
|
|
| + |
| VDC | + | – |
| – | ||
|
| ||
|
|
| mA1 |
|
|
| HART- |
|
|
| compatible host |
Rload |
| or controller | |
|
| ||
Ω |
|
| |
resistance) |
|
|
Note: See Figure
Output Wiring – Intrinsically Safe
Output Wiring – Configurable I/O Output Wiring – Fieldbus/PROFIBUS
Specifications